    							2-91
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      1-Gigabit Ethernet Modules
    Digital Optical Monitoring 
    (DOM) supportSupported on some GBIC transceivers. 
    NoteRefer to your software release notes for specific information on 
    which GBIC transceivers support DOM and the software 
    release required for support.
    Module front panel LEDsSTATUS
    Green—All diagnostics pass; the module is operational.
    Orange—The module is booting or running diagnostics; an 
    overtemperature condition has occurred.
    LINK
    Green—The port is active (the link is connected and operational).
    Flashing orange—The port failed diagnostics and is disabled.
    Orange—The port is disabled.
    Red—The module is resetting; an overtemperature condition has 
    occurred. 
    NoteIf the module fails to download code and configuration 
    information successfully during the initial reset, the LED stays 
    red; the module does not come online.
    Off—The port is not active or the link is not connected.
    Table 2-52 WS-X6816-GBIC Ethernet Module Features (continued)
    Feature Description 
    						
    							2-92
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      1-Gigabit Ethernet Modules
    Table 2-53 WS-X6816-GBIC Physical and Environmental Specifications 
    Item Specification
    Dimensions (H x W x D) 1.2 x 14.4 x 16 in. (3.0 x 35.6 x 40.6 cm). Occupies one slot in the chassis.
    Weight Base module—9.2 lb (4.2 kg)
    Power and heat numbers
    Base module + DFC daughter card (WS-F6K-DFC3A)
     –Module current—5.94 A
     –Module power—249.48 W
     –AC-input power—311.85 W
     –AC heat dissipation—1064.97 BTU/hour
     –DC-input power—335.32 W
     –DC heat dissipation—1145.13 BTU/hour
    Base module + DFC daughter card (WS-F6K-DFC3B)
     –Module current—5.51 A
     –Module power—231.42 W
     –AC-input power—289.28 W
     –AC heat dissipation—987.87 BTU/hour
     –DC-input power—311.05 W
     –DC heat dissipation—1062.23 BTU/hour
    Base module + DFC daughter card (WS-F6K-DFC3BXL)
     –Module current—6.22 A
     –Module power—261.24 W
     –AC-input power—326.55 W
     –AC heat dissipation—1115.17 BTU/hour
     –DC-input power—351.13 W
     –DC heat dissipation—1199.11 BTU/hour
    Environment11.2 lb (5.08 kg)
    Operating temperature
    Certified for operation: 32° to 104°F (0° to 40°C)
    Designed and tested for operation: 32° to 130°F (0° to 55°C)
    Humidity (RH) ambient 
    (noncondensing)10 to 90%
    Operating altitude
    Certified for operation: 0 to 6500 ft (0 to 2000 m)
    Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m) 
    						
    							2-93
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      10-Gigabit Ethernet Modules
    10-Gigabit Ethernet Modules
    This section describes the following 10-Gigabit Ethernet modules:
    WS-X6704-10GE Ethernet Module, page 2-93
    WS-X6708-10G-3C and WS-X6708-10G-3CXL Ethernet Modules, page 2-98
    WS-X6716-10GE and WS-X6816-10G-2T/-2TXL Ethernet Modules, page 2-102
    WS-X6716-10T and WS-X6816-10T-2T/-2TXL Ethernet Modules, page 2-108
    NoteAll of the 10-Gigabit Ethernet modules are hot swappable.
    WS-X6704-10GE Ethernet Module
    The WS-X6704-10GE Ethernet module (Figure 2-25) provides 4 10-Gbps full- or half-duplex ports. 
    Table 2-54 lists the module features, and Table 2-55 lists the module physical and environmental 
    specifications. 
    Figure 2-25 WS-X6704-10GE Ethernet Module Front Panel
    Table 2-54 WS-X6704-10GE Ethernet Module Features 
    Feature Description
    Ports per module
    4 ports. Ports are numbered from 1 (left) to 4 (right).
    4 port groups
    Port ranges per port group: 1 port in each group
    Port connector type SC or InfiniBand 4X depending on the type of XENPAK transceiver 
    installed in the module.
    Cabling distance Depends on the XENPAK transceiver installed in the module port. 
    Refer to Appendix B for supported XENPAK transceiver types and 
    cabling distances.
    Buffer size 16 MB
    QoS
    Number of egress queues: 8
    Number of ingress queues: 1 (8 if DFC3x is present)
    Number of thresholds per egress queue: 8
    Number of thresholds per ingress queue: 8
    Maximum frame size Up to 9216 bytes
    Module oversubscription rate Approximately 1:1
    WS-X6704-10GE
    STATUS
    LINK 1
    LINK 2
    LINK 3
    LINK 4PORT 1
    TX RXPORT 2
    TX RXPORT 3
    TX RXPORT 4
    TX RX
    4 PORT 10 GIGABIT ETHERNET99885 
    						
    							2-94
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      10-Gigabit Ethernet Modules
    Supervisor engine support Supported on the following supervisor engines:
    Supervisor Engine 720
    Supervisor Engine 720-10GE
    Supervisor Engine 2T (module must be equipped with a CFC 
    daughter card or either a DFC4-A or DFC4-AXL daughter card)
    Software support
    With Supervisor Engine 720—12.2(17a)SX
    With Supervisor Engine 720 and DFC3C or 
    DFC3CXL—12.2(33)SXH
    With Supervisor Engine 720-10GE—12.2(33)SXH
    With Supervisor Engine 2T (module equipped with either CFC, 
    DFC4-A, or DFC4-AXL daughter card)—12.2(50)SY
    Queues per port
    With CFC daughter card:
     –Tx—1p7q8t
     –Rx—1q8t
    With DFC daughter card:
     –Tx—1p7q8t
     –Rx—8q8t
    Chassis/slot restrictions
    Not supported in the Catalyst 6503 chassis. 
    Supported only in slots 9–13 in the Catalyst 6513 chassis. The 
    module does not power up if it is installed in slots 1–8.
    Switch fabric connection
    Dual switch-fabric connections:
     –Fabric channel 1—Ports 3 and 4
     –Fabric channel 2—Ports 1 and 2
    Fabric channel speed 20 Gb/sec
    Module upgrades available
    PoE support Not supported.
    Distributed forwarding 
    supportShips with the WS-F6700-CFC daughter card factory-installed. Can be 
    upgraded in the field with a DFC daughter card (WS-F6700-DFC3A, 
    WS-F6700-DFC3B, WS-F6700-DFC3B, WS-F6700-DFC3C, 
    WS-F6700-DFC3CXL, WS-)F6K-DFC4-A, or WS-F6K-DFC4-AXL.
    Pluggable transceivers 
    supportXENPAK transceivers are supported. Refer to your software release 
    notes to determine which XENPAK transceivers are supported. See the 
    “10-GB Transceivers” section on page B-8 in Appendix B for 
    additional information on the XENPAK transceivers.
    Table 2-54 WS-X6704-10GE Ethernet Module Features (continued)
    Feature Description 
    						
    							2-95
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      10-Gigabit Ethernet Modules
    Digital Optical Monitoring 
    (DOM) supportSupported on some XENPAK transceivers. 
    NoteRefer to your software release notes for specific information on 
    which XENPAK transceivers support DOM and the software 
    release required for support.
    Module front panel LEDsSTATUS
    Green—All diagnostics pass; the module is operational.
    Orange—The module is booting or running diagnostics; an 
    overtemperature condition has occurred.
    LINK
    Green—The port is active (the link is connected and operational).
    Flashing orange—The port failed diagnostics and is disabled.
    Orange—The port is disabled.
    Red—The module is resetting; an overtemperature condition has 
    occurred. 
    NoteIf the module fails to download code and configuration 
    information successfully during the initial reset, the LED stays 
    red; the module does not come online.
    Off—The port is not active or the link is not connected.
    Table 2-54 WS-X6704-10GE Ethernet Module Features (continued)
    Feature Description 
    						
    							2-96
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      10-Gigabit Ethernet Modules
    Table 2-55 WS-X6704-10GE Ethernet Module Physical and Environmental Specifications 
    Item Specification
    Dimensions 1.2 x 14.4 x 16 in. (3.0 x 35.6 x 40.6 cm). Occupies one slot in the 
    chassis.
    Weight Base module + CFC daughter card (WS-F6700-CFC)—9.0 lb (4.08 kg)
    Power and heat numbers
    WS-X6704-10GE (base module + CFC daughter card)
     –Module current—7.03 A
     –Module power—295.26 W
     –AC-input power—369.08 W
     –AC heat dissipation—1260.39 BTU/hour
     –DC-input power—396.85 W
     –DC heat dissipation—1355.26 BTU/hour
    WS-X6704-10GE (base module + DFC3A daughter card)
     –Module current—9.28 A
     –Module power—389.76 W
     –AC-input power—487.20 W
     –AC heat dissipation—1663.79 BTU/hour
     –DC-input power—523.87 W
     –DC heat dissipation—1789.02 BTU/hour
    WS-X6704-10GE (base module + DFC3B daughter card)
     –Module current—8.98 A
     –Module power—377.16 W
     –AC-input power—471.45 W
     –AC heat dissipation—1610.00 BTU/hour
     –DC-input power—506.94 W
     –DC heat dissipation—1731.18 BTU/hour
    WS-X6704-10GE (base module + DFC3BXL daughter card)
     –Module current—9.58 A
     –Module power—402.36 W
     –AC-input power—502.95 W
     –AC heat dissipation—1717.57 BTU/hour
     –DC-input power—540.81 W
     –DC heat dissipation—1846.85 BTU/hour 
    						
    							2-97
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      10-Gigabit Ethernet Modules
    Power and heat numbers
    (continued)WS-X6704-10GE (base module + DFC3C daughter card)
     –Module current—7.93 A
     –Module power—333.06 W
     –AC-input power—416.33 W
     –AC heat dissipation—1421.75 BTU/hour
     –DC-input power—447.66 W
     –DC heat dissipation—1528.76 BTU/hour
    WS-X6704-10GE (base module + DFC3CXL daughter card)
     –Module current—8.63 A
     –Module power—362.46 W
     –AC-input power—453.08 W
     –AC heat dissipation—1547.25 BTU/hour
     –DC-input power—487.18 W
     –DC heat dissipation—1663.71 BTU/hour
    Environment
    Operating temperature
    Certified for operation: 32° to 104°F (0° to 40°C)
    Designed and tested for operation: 32° to 130°F (0° to 55°C)
    Humidity (RH) ambient 
    (noncondensing)10 to 90%
    Operating altitude
    Certified for operation: 0 to 6500 ft (0 to 2000 m)
    Designed and tested for operation: –200 to 10,000 ft (–60 to 
    3000 m)
    Table 2-55 WS-X6704-10GE Ethernet Module Physical and Environmental Specifications (continued)
    Item Specification 
    						
    							2-98
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      10-Gigabit Ethernet Modules
    WS-X6708-10G-3C and WS-X6708-10G-3CXL Ethernet Modules
    The WS-X6708-10G-3C and WS-X6708-10G-3CXL Ethernet module (Figure 2-26) provides 8 10-Gbps 
    full- or half-duplex ports. Table 2-54 lists the module features, and Table 2-55 lists the module physical 
    and environmental specifications. 
    Figure 2-26 WS-X6708-10G-3C and WS-X6708-10G-3CXL Ethernet Module Front Panel
    NoteBoth of the modules (WS-X6708-10G-3C and WS-X6708-10G-3CXL) are identified on the faceplate as 
    WS-X6708-10GE.
    Table 2-56 WS-X6708-10G-3C and WS-X6708-10G-3CXL Ethernet Module Features 
    Feature Description
    Ports per module
    8 ports. Ports are numbered from 1 (left) to 8 (right).
    1 port group
    Port ranges per port group: 1–8
    Port connector type SC or CX4 depending on the type of X2 transceiver installed in the 
    module port.
    Cabling distance Depends on the X2 transceiver installed in the module port. Refer to 
    Appendix B for supported X2 transceiver types and cabling distances.
    Buffer size 200 MB per port
    QoS
    Number of egress queues: 8
    Number of ingress queues: 8
    Number of thresholds per egress queue: 4
    Number of thresholds per ingress queue: 4
    Maximum frame size Up to 9216 bytes
    Module oversubscription rate 2:1
    Supervisor engine support Supported on the following supervisor engines:
    Supervisor Engine 720
    Supervisor Engine 720-10GE
    NoteCheck your release notes for specific information on the 
    software release versions required to support the supervisor 
    engines.
    Software support
    With Supervisor Engine 720—12.2(18)SXF5
    With Supervisor Engine 720-10GE—12.2(33)SXH
    184597 
    						
    							2-99
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      10-Gigabit Ethernet Modules
    Queues per portTx—1p7q4t
    Rx—8q4t
    Chassis/slot restrictions
    Not supported in the Catalyst 6503 chassis. 
    Supported only in slots 9–13 in the Catalyst 6513 chassis. The 
    module does not power up if it is installed in slots 1–8.
    When the WS-X6708-10G module is installed in a Catalyst  6500-E 
    series chassis or a Catalyst 6509-NEB-A chassis, the configuration 
    is NEBS 3 compliant (chassis supports operating temperatures up 
    to 55°C). 
    When the WS-X6708-10G module is installed in a Catalyst 6500 
    non-E series chassis that is equipped with a fan tray 2 and a 
    2500 W or larger power supply, the configuration is not NEBS 3 
    compliant (chassis supports operating temperatures up to 40°C 
    only).
    Support for the Catalyst 6509-NEB-A chassis requires two 
    FAN-MOD-09 fan trays.
    Fabric connection
    Dual switch-fabric connections:
     –Fabric channel 1: Ports 2, 3, 6, 8
     –Fabric channel 2: Ports 1, 4, 5, 7
    Fabric channel speed 20 Gb/sec
    Module upgrades available
    PoE support Not supported.
    Distributed forwarding 
    support
    WS-X6708-10G-3C comes factory-equipped with a DFC3C 
    daughter card.
    WS-X6708-10G-3CXL comes factory-equipped with a DFC3CXL 
    daughter card.
    Pluggable transceivers 
    supportX2 transceivers are supported. Not all types of X2 transceivers may be 
    supported. Refer to your software release notes to determine which X2 
    transceivers are currently supported. See the “10-GB Transceivers” 
    section on page B-8 in Appendix B for additional information on the 
    X2 transceivers.
    NoteThe WS-6708-10GE does not support X2 transceivers shipped 
    prior to the release of the WS-X6708-10GE with Cisco IOS 
    Release 12.2(18)SXF5. The unsupported X2 transceivers are 
    labeled with a number that ends with -01. This restriction does 
    not apply to the X2-10GB-LRM transceiver.
    Table 2-56 WS-X6708-10G-3C and WS-X6708-10G-3CXL Ethernet Module Features (continued)
    Feature Description 
    						
    							2-100
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      10-Gigabit Ethernet Modules
    Digital Optical Monitoring 
    (DOM) supportSupported on some X2 transceivers.
    NoteRefer to your software release notes for specific information on 
    which X2 transceivers support DOM and the software release 
    required for support.
    Module front panel LEDsSTATUS
    Green—All diagnostics pass; the module is operational.
    Orange—The module is booting or running diagnostics; an 
    overtemperature condition has occurred.
    LINK
    Green—The port is active (the link is connected and operational).
    Flashing orange—The port failed diagnostics and is disabled.
    Orange—The port is disabled.
    Red—The module is resetting; an overtemperature condition has 
    occurred. 
    NoteIf the module fails to download code and configuration 
    information successfully during the initial reset, the LED stays 
    red; the module does not come online.
    Off—The port is not active or the link is not connected.
    Table 2-56 WS-X6708-10G-3C and WS-X6708-10G-3CXL Ethernet Module Features (continued)
    Feature Description 
    						