A - 42 HL7050_US_UG_FM5.5 The symbol sets marked with an * are variations of the Roman-8 symbol set. PCL Symbol Set Typeface Set ID Symbol Set Tennessee Helsinki BR Symbol W Dingbats Atlanta Book Copenhagen Portugal Calgary Germany San Diego Bermuda Script US Roman 9E Windows 3.1 Latin 2 9J PC-1004 (OS/2) 9T PC Turkish 9U Windows 3.0 Latin 1 10JPS Text 10UPC-8 11U PC-8 D/N 12JMC Text 12U PC-850 13J Ventura International 14J Ventura US 15U Pi Font 17U PC-852 19L Windows Baltic 19U Windows 3.1 Latin 1 26U PC-775 19M Symbol 579L Wingdings 0O OCR-A 1O OCR-B
A - 43 HL7050_US_UG_FM5.5 Quick reference for commands Bar code control The printer can print bar codes in the HP LaserJet, EPSON FX-850, and IBM Proprinter XL emulation modes. Print bar codes or expanded characters CodeESC i Dec27 105 Hex1B 69 Format: ESC i n ... n \ Creates bar codes or expanded characters according to the segment of parameters n ... n. For more information about parameters, see the following Definition of Parameters. This command must end with the code (5CH). Definition of Parameters This bar code command can have the following parameters in the parameter segment (n ... n). As parameters are effective within the single command syntax ESC i n ... n \, they dont apply in the bar code commands. If certain parameters are not given, they take the preset settings. The last parameter must be the bar code data start (b or B) or the expanded character data start (l or L). Other parameters can be given in any sequence. Each parameter can start with a lower-case or upper-case character, for example, t0 or T0, s3 or S3 and so one.
A - 44 HL7050_US_UG_FM5.5 Bar code mode n = t0 or T0 CODE 39 (default) n = t1 or T1 Interleaved 2 of 5 n = t3 or T3 FIM (US-Post Net) n = t4 or T4 Post Net (US-Post Net) n = t5 or T5 EAN 8, EAN 13, or UPC A n = t6 or T6 UPC E n = t9 or T9 Codabar n = t12 or T12 Code 128 set A n = t13 or T13 Code 128 set B n = t14 or T14 Code 128 set C n = t130 or T130 ISBN (EAN) n = t131 or T131 ISBN (UPC-E) n = t132 or T132 EAN 128 set A n = t133 or T133 EAN 128 set B n = t134 or T134 EAN 128 set C This parameter selects the bar code mode as shown above. When n is t5 or T5 the bar code mode (EAN 8, EAN 13, or UPC A) varies according to the number of characters in the data.
A - 45 HL7050_US_UG_FM5.5 Bar Code, expanded character, line block drawing and box drawing n = s0 or S0 3: 1 (default) n = s1 or S1 2: 1 n = s3 or S3 2.5: 1 This parameter selects the bar code style as above. When the EAN 8, EAN 13, UPC-A, Code 128 or EAN 128 bar code mode is selected, this bar code style parameter is ignored. Expanded Character S 0 = White 1 = Black 2 = Vertical stripes 3 = Horizontal stripes 4 = Cross hatch For example S n1 n2 n1 = Background fill pattern n2 = Foreground fill pattern If S is followed by only one parameter, the parameter is a foreground fill pattern. Line block drawing & box drawing S 1 = Black 2 = Vertical stripes 3 = Horizontal stripes 4 = Cross hatch Bar Code n = mnnn or Mnnn (nnn = 0 ~ 32767) This parameter shows the bar code width. The unit of nnn is a percentage.
A - 46 HL7050_US_UG_FM5.5 Bar code human readable line ON or OFF n = r0 or R0 Human readable line OFF n = r1 or R1 Human readable line ON Preset: Human readable line ON (1) T5 or t5 (2) T6 or t6 (3) T130 or t130 (4) T131 or t131 Preset: Human readable line OFF All others This parameter shows whether or not the printer prints the human readable line below the bar code. Human readable characters are always printed with OCR-B font of 10 pitch and all the current character style enhancements are masked. The factory setting is determined by the bar code mode selected by t or T. Quiet zone n = onnn or Onnn (nnn = 0 ~ 32767) Quiet zone is the space on both sides of the bar codes. Its width can be shown using the units that are set by the u of U parameter. (For the description of u or U parameter, see the next section.) The factory setting of the quiet-zone width is 1 inch. Bar code, expanded character unit, line block drawing and box drawing n = u0 or U0 mm (preset) n = u1 or U1 1/10 n = u2 or U2 1/100 n = u3 or U3 1/12 n = u4 or U4 1/120 n = u5 or U5 1/10 mm n = u6 or U6 1/300 n = u7 or U7 1/720 This parameter shows the measurement units of X-axis offset, Y-axis offset, and bar code height.
A - 47 HL7050_US_UG_FM5.5 Bar code, expanded character, line block drawing and box drawing offset in X-axis n = xnnn or Xnnn This parameter shows the offset from the left margin in the u- or U- specified unit. Bar code & expanded character offset in Y-axis n = ynnn or Ynnn This parameter shows the downward offset from the current print position in the u- or U-specified unit. Bar code, expanded character, line block drawing and box drawing height n = hnnn, Hnnn, dnnn, or Dnnn (1) EAN13, EAN8, UPC-A, ISBN (EAN13, EAN8, UPC-A), ISBN (UPC-E): 22 mm (2) UPC-E: 18 mm (3) Others: 12 mm Expanded characters → 2.2 mm (preset) Line block drawing and box drawing →1 dot This parameter shows the height of bar codes or expanded characters as shown above. It can start with h, H, d, or D. The height of bar codes is shown in the u- or U-specified unit. The factory setting of the bar code height (12 mm, 18 mm or 22 mm) is determined by the bar code mode selected by t or T. Expanded character width, line block drawing and box drawing n = wnnn or Wnnn Expanded character→ 1.2 mm Line block drawing and box drawing→ 1 dot This parameter shows the width of expanded characters as shown above.
A - 48 HL7050_US_UG_FM5.5 Expanded character rotation n = a0 or A1 Upright (preset) n = a1 or A1 Rotated 90 degrees n = a2 or A2 Upside down, rotated 180 degrees n = a3 or A3 Rotated 270 degrees Bar code data start n = b or B Data that follows b or B is read in as bar code data. Bar code data must end with the code (5CH), which also ends this command. The acceptable bar code data is determined by the bar code mode selected by t or T. ■When CODE 39 is selected with the parameter t0 or T0 Forty three characters 0 to 9, A to Z, -, . , (space), $, / , +, and % can be accepted as bar code data. Other characters will cause a data error. The number of characters for bar codes is not limited. The bar code data automatically starts and ends with an asterisk * (start character and stop character). If the received data has an asterisk * at the beginning or end, the asterisk is regarded as a start character or stop character. ■When Interleaved 2 of 5 is selected with the parameter t1 or T1: Ten numerical characters 0 to 9 can be accepted as bar code data. Other characters cause a data error. The number of characters for bar codes is not limited. Because this mode of bar codes needs even characters, if the bar code data has odd characters, 0 is automatically added to the end of the bar code data. ■When FIM (US-Post Net) is selected with the parameter t3 or T3 Characters A to D are valid and one digit of data can be printed. Upper-case and lower-case alphabet characters can be accepted. ■When Post Net (US-Post Net) is selected with the parameter t4 or T4 Numbers 0 to 9 can be data and it must end with a check digit. ? can be used instead of the check digit.
A - 49 HL7050_US_UG_FM5.5 ■When EAN 8, EAN 13, or UPC A is selected with the parameter t5 or T5 Ten numbers 0 to 9 can be accepted as bar code data. The number of characters for bar codes is limited as follows: EAN 8: Total 8 digits (7 digits + 1 check digit) EAN 13: Total 13 digits (12 digits + 1 check digit) UPC A: Total 12 digits (11 digits + 1 check digit) A number of characters other than above will cause data error that results in the bar code data being printed as normal print data. If the check digit is not correct, the printer calculates the correct check digit automatically so that the correct bar code data will be printed. When EAN13 is selected, adding + and a two-digit or five-digit number after the data can create an add-on code. ■When UPC-E is selected with the parameter t6 or T6: The numbers 0 to 9 can be accepted as bar code data. 1 Eight digits (standard format) The first character must be 0 and the data must end with a check digit. Total eight digits = 0 plus 6 digits plus 1 check digit. 2 Six digits The first character and the last check digit are removed from the eight digit data. 1: For eight digits, ? can be used instead of a check digit. 2: Adding + and two-digit or five-digit number after the data creates an add-on code for all six and eight digit formats. ■When Codebar is chosen with the parameter t9 or T9 Characters 0 to 9, -, . , $, /, +, : can be printed. Characters A to D can be printed as a start-stop code, which can be upper case or lower case. If there is no start-stop code, errors will happen. A check digit cannot be added and using ? causes errors. ■When Code 128 Set A, Set B, or Set C is selected with the parameter t12 or T12, t13 or T13, or t14 or T14
A - 50 HL7050_US_UG_FM5.5 Code 128 sets A, B and C can be individually selected. Set A indicates characters Hex 00 to 5F. Set B includes characters Hex 20 to 7F. Set C includes the pairs 00 to 99. Switching is allowed between the code sets by sending %A, %B, or %C. FNC 1, 2, 3, and 4 are produced with %1, %2, %3, and %4. The SHIFT code, %S, allows temporary switching (for one character only) from set A to set B and vice versa. The % character can be encoded by sending it twice. ■When ISBN (EAN) is selected with the parameter t130 or T130 The same rules apply as for t5 or T5. ■When ISBN (UPC-E) is selected with the parameter t131 or T131: The same rules apply as for t6 or T6. ■When EAN 128 set A, set B or set C is selected with the parameter t132 or T132, t133 or T133 or t134 or T134 The same rules apply as for t12 or T12, t13 or T13, or t14 or T14. Box drawing ESC i ... E (or e) E or e is a terminator. Line block drawing ESC i ... V (or v) V or v is a terminator. Expanded character data start n = l or L Data that follows l or L is read as expanded character data (or labeling data). Expanded character data must end with the code (5CH), which also ends this command.
A - 51 HL7050_US_UG_FM5.5 Example Program Listings WIDTH LPT1:,255 CODE 39 LPRINT CHR$(27);it0r1s0o0x00y00bCODE39?\; Interleaved 2 of 5 LPRINT CHR$(27);it1r1s0o0x00y20b123456?\; FIM LPRINT CHR$(27);it3r1o0x00y40bA\; Post Net LPRINT CHR$(27);it4r1o0x00y60b1234567890?\; EAN-8 LPRINT CHR$(27);it5r1o0x00y70b1234567?\; UPC-A LPRINT CHR$(27);it5r1o0x50y70b12345678901?\; EAN-13 LPRINT CHR$(27);it5r1o0x100y70b123456789012?\; UPC-E LPRINT CHR$(27);it6r1o0x150y70b0123456?\; Codabar LPRINT CHR$(27);it9r1s0o0x00y100bA123456A\; Code 128 set A LPRINT CHR$(27);it12r1o0x00y120bCODE128A12345?\; Code 128 set B LPRINT CHR$(27);it13r1o0x00y140bCODE128B12345?\; Code 128 set C LPRINT CHR$(27);it14r1o0x00y160b;CHR$(1);CHR$(2);?\; ISBN(EAN) LPRINTCHR$(27);it130r1o0x00y180b123456789012?+12345\; EAN 128 set A LPRINT CHR$(27);it132r1o0x00y210b1234567890?\; LPRINT CHR$(12) END