Home > Brother > Printer > Brother HL 7050N User Manual

Brother HL 7050N User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Brother HL 7050N User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 331 Brother manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							A - 42 
    HL7050_US_UG_FM5.5
    The symbol sets marked with an * are variations of the Roman-8 symbol set. 
    PCL Symbol Set Typeface
    Set ID Symbol Set Tennessee Helsinki BR Symbol W Dingbats Atlanta Book Copenhagen Portugal Calgary Germany San Diego Bermuda Script US Roman
    9E Windows 3.1 Latin 2  
    9J PC-1004 (OS/2)  
    9T PC Turkish  
    9U Windows 3.0 Latin 1          
    10JPS Text  
    10UPC-8  
    11U PC-8 D/N          
    12JMC Text  
    12U PC-850          
    13J Ventura International          
    14J Ventura US          
    15U Pi Font          
    17U PC-852  
    19L Windows Baltic  
    19U Windows 3.1 Latin 1          
    26U PC-775  
    19M Symbol 
    579L Wingdings
    0O OCR-A
    1O OCR-B
     
    						
    							 A - 43
    HL7050_US_UG_FM5.5
    Quick reference for commands 
    Bar code control
    The printer can print bar codes in the HP LaserJet, EPSON 
    FX-850, and IBM Proprinter XL emulation modes. 
    Print bar codes or expanded characters
    CodeESC i
    Dec27 105
    Hex1B 69
    Format: ESC i n ... n \
    Creates bar codes or expanded characters according to the segment 
    of parameters n ... n. For more information about parameters, see 
    the following Definition of Parameters.  This command must end with 
    the    code (5CH). 
    Definition of Parameters
    This bar code command can have the following parameters in the 
    parameter segment (n ... n).  As parameters are effective within the 
    single command syntax ESC i n ... n \, they dont apply in the bar 
    code commands.  If certain parameters are not given, they take the 
    preset settings.  The last parameter must be the bar code data start 
    (b or B) or the expanded character data start (l or L). Other 
    parameters can be given in any sequence.  Each parameter can start 
    with a lower-case or upper-case character, for example, t0 or T0, 
    s3 or S3 and so one. 
     
    						
    							A - 44 
    HL7050_US_UG_FM5.5
    Bar code mode
    n = t0 or T0 CODE 39 (default)
    n = t1 or T1 Interleaved 2 of 5
    n = t3 or T3  FIM (US-Post Net)
    n = t4 or T4  Post Net (US-Post Net)
    n = t5 or T5 EAN 8, EAN 13, or UPC A 
    n = t6 or T6 UPC E
    n = t9 or T9 Codabar
    n = t12 or T12 Code 128 set A
    n = t13 or T13 Code 128 set B
    n = t14 or T14 Code 128 set C
    n = t130 or T130 ISBN (EAN)
    n = t131 or T131 ISBN (UPC-E)
    n = t132 or T132 EAN 128 set A
    n = t133 or T133 EAN 128 set B
    n = t134 or T134 EAN 128 set C
    This parameter selects the bar code mode as shown above. When n 
    is t5 or T5 the bar code mode (EAN 8, EAN 13, or UPC A) varies 
    according to the number of characters in the data. 
     
    						
    							 A - 45
    HL7050_US_UG_FM5.5
    Bar Code, expanded character, line block drawing and box 
    drawing 
    n = s0 or S0 3: 1 (default)
    n = s1 or S1 2: 1
    n = s3 or S3 2.5: 1
    This parameter selects the bar code style as above.  When the EAN 
    8, EAN 13, UPC-A, Code 128 or EAN 128 bar code mode is selected, 
    this bar code style parameter is ignored. 
    Expanded Character
    S
    0 = White
    1 = Black
    2 = Vertical stripes
    3 = Horizontal stripes
    4 = Cross hatch
    For example S n1 n2 
    n1 = Background fill pattern
    n2 = Foreground fill pattern
    If S is followed by only one parameter, the parameter is a 
    foreground fill pattern.
    Line block drawing & box drawing
    S
    1 = Black
    2 = Vertical stripes
    3 = Horizontal stripes
    4 = Cross hatch
    Bar Code 
    n = mnnn or Mnnn (nnn = 0 ~ 32767)
    This parameter shows the bar code width.  The unit of nnn is a 
    percentage.
     
    						
    							A - 46 
    HL7050_US_UG_FM5.5
    Bar code human readable line ON or OFF
    n = r0 or R0 Human readable line OFF
    n = r1 or R1 Human readable line ON
    Preset: Human readable line ON
    (1)  T5 or t5
    (2)  T6 or t6
    (3)  T130 or t130
    (4)  T131 or t131
    Preset: Human readable line OFF
    All others
    This parameter shows whether or not the printer prints the human 
    readable line below the bar code.  Human readable characters are 
    always printed with OCR-B font of 10 pitch and all the current 
    character style enhancements are masked.  The factory setting is 
    determined by the bar code mode selected by t or T.
    Quiet zone
    n = onnn or Onnn (nnn = 0 ~ 32767)
    Quiet zone is the space on both sides of the bar codes.  Its width can 
    be shown using the units that are set by the u of U parameter. (For 
    the description of u or U parameter, see the next section.)  The 
    factory setting of the quiet-zone width is 1 inch. 
    Bar code, expanded character unit, line block drawing and box 
    drawing
    n = u0 or U0 mm (preset)
    n = u1 or U1 1/10
    n = u2 or U2 1/100
    n = u3 or U3 1/12
    n = u4 or U4 1/120 
    n = u5 or U5 1/10 mm
    n = u6 or U6 1/300
    n = u7 or U7 1/720
    This parameter shows the measurement units of X-axis offset, Y-axis 
    offset, and bar code height.
     
    						
    							 A - 47
    HL7050_US_UG_FM5.5
    Bar code, expanded character, line block drawing and box 
    drawing offset in X-axis
    n = xnnn or Xnnn
    This parameter shows the offset from the left margin in the u- or U-
    specified unit. 
    Bar code & expanded character offset in Y-axis
    n = ynnn or Ynnn
    This parameter shows the downward offset from the current print 
    position in the u- or U-specified unit. 
    Bar code, expanded character, line block drawing and box 
    drawing height
    n = hnnn, Hnnn, dnnn, or Dnnn
    (1) EAN13, EAN8, UPC-A, ISBN (EAN13, EAN8, UPC-A), 
    ISBN (UPC-E): 22 mm
    (2) UPC-E: 18 mm
    (3) Others: 12 mm
    Expanded characters → 2.2 mm (preset) 
    Line block drawing and box drawing →1 dot
    This parameter shows the height of bar codes or expanded 
    characters as shown above.  It can start with h, H, d, or D.  The 
    height of bar codes is shown in the u- or U-specified unit.  The 
    factory setting of the bar code height (12 mm, 18 mm or 22 mm) is 
    determined by the bar code mode selected by t or T. 
    Expanded character width, line block drawing and box drawing
    n = wnnn or Wnnn
    Expanded character→ 1.2 mm
    Line block drawing and box drawing→ 1 dot
    This parameter shows the width of expanded characters as shown 
    above. 
     
    						
    							A - 48 
    HL7050_US_UG_FM5.5
    Expanded character rotation
    n = a0 or A1 Upright (preset)
    n = a1 or A1 Rotated 90 degrees
    n = a2 or A2 Upside down, rotated 180 degrees
    n = a3 or A3 Rotated 270 degrees
    Bar code data start
    n = b or B
    Data that follows b or B is read in as bar code data.  Bar code data 
    must end with the    code (5CH), which also ends this command.  
    The acceptable bar code data is determined by the bar code mode 
    selected by t or T. 
    ■When CODE 39 is selected with the parameter t0 or T0  
    Forty three characters 0 to 9, A to Z, -,  . ,   (space), $,  / , +, 
    and % can be accepted as bar code data.  Other characters will  
    cause a data error.  The number of characters for bar codes is not 
    limited.  The bar code data automatically starts and ends with an 
    asterisk  *  (start character and stop character). If the received data 
    has an asterisk  *  at the beginning or end, the asterisk is regarded 
    as a start character or stop character. 
    ■When Interleaved 2 of 5 is selected with the parameter t1 or T1:  
    Ten numerical characters 0 to 9 can be accepted as bar code data. 
    Other characters cause a data error. The number of characters for 
    bar codes is not limited.  Because this mode of bar codes needs even 
    characters, if the bar code data has odd characters, 0 is 
    automatically added to the end of the bar code data. 
    ■When FIM (US-Post Net) is selected with the parameter t3 or T3  
    Characters A to D are valid and one digit of data can be printed. 
    Upper-case and lower-case alphabet characters can be accepted. 
    ■When Post Net (US-Post Net) is selected with the parameter t4 
    or T4  
    Numbers 0 to 9 can be data and it must end with a check digit. ? 
    can be used instead of the check digit. 
     
    						
    							 A - 49
    HL7050_US_UG_FM5.5
    ■When EAN 8, EAN 13, or UPC A is selected with the parameter t5 
    or T5  
    Ten numbers 0 to 9 can be accepted as bar code data.  The 
    number of characters for bar codes is limited as follows:
    EAN 8: Total 8 digits (7 digits + 1 check digit)
    EAN 13: Total 13 digits (12 digits + 1 check digit)
    UPC A: Total 12 digits (11 digits + 1 check digit)
    A number of characters other than above will cause data error that 
    results in the bar code data being printed as normal print data. If the 
    check digit is not correct, the printer calculates the correct check digit 
    automatically so that the correct bar code data will be printed.  When 
    EAN13 is selected, adding + and a two-digit or five-digit number 
    after the data can create an add-on code. 
    ■When UPC-E is selected with the parameter t6 or T6:  
    The numbers 0 to 9 can be accepted as bar code data. 
    1 Eight digits (standard format) The first character must be 0 and 
    the data must end with a check digit.  
    Total eight digits = 0 plus 6 digits plus 1 check digit.
    2 Six digits The first character and the last check digit are 
    removed from the eight digit data. 
    1: For eight digits, ? can be used instead of a check digit. 
    2: Adding + and two-digit or five-digit number after the data creates  
    an add-on code for all six and eight digit formats. 
    ■When Codebar is chosen with the parameter t9 or T9  
    Characters 0 to 9, -,  . , $, /, +,  :  can be printed.   Characters 
    A to D can be printed as a start-stop code, which can be upper case 
    or lower case.  If there is no start-stop code, errors will happen.  A 
    check digit cannot be added and using ? causes errors. 
    ■When Code 128 Set A, Set B, or Set C is selected with the 
    parameter t12 or T12, t13 or T13, or t14 or T14  
     
    						
    							A - 50 
    HL7050_US_UG_FM5.5
    Code 128 sets A, B and C can be individually selected.  Set A 
    indicates characters Hex 00 to 5F.  Set B includes characters Hex 20 
    to 7F.  Set C includes the pairs 00 to 99.  Switching is allowed 
    between the code sets by sending %A, %B, or %C.  FNC 1, 2, 3, and 
    4 are produced with %1, %2, %3, and %4.  The SHIFT code, %S, 
    allows temporary switching (for one character only) from set A to set 
    B and vice versa.  The % character can be encoded by sending it 
    twice. 
    ■When ISBN (EAN) is selected with the parameter t130 or T130  
    The same rules apply as for t5 or T5.
    ■When ISBN (UPC-E) is selected with the parameter t131 or 
    T131:  
    The same rules apply as for t6 or T6.
    ■When EAN 128 set A, set B or set C is selected with the parameter 
    t132 or T132, t133 or T133 or t134 or T134  
    The same rules apply as for t12 or T12, t13 or T13, or t14 or 
    T14.
    Box drawing
    ESC i ... E (or e)
    E or e is a terminator. 
    Line block drawing
    ESC i ... V (or v)
    V or v is a terminator. 
    Expanded character data start
    n = l or L
    Data that follows l or L is read as expanded character data (or 
    labeling data).  Expanded character data must end with the    code 
    (5CH), which also ends this command.
     
    						
    							 A - 51
    HL7050_US_UG_FM5.5
    Example Program Listings
          WIDTH LPT1:,255
          CODE 39
          LPRINT CHR$(27);it0r1s0o0x00y00bCODE39?\;
          Interleaved 2 of 5
          LPRINT CHR$(27);it1r1s0o0x00y20b123456?\;
          FIM
          LPRINT CHR$(27);it3r1o0x00y40bA\;
          Post Net
          LPRINT CHR$(27);it4r1o0x00y60b1234567890?\;
          EAN-8
          LPRINT CHR$(27);it5r1o0x00y70b1234567?\;
          UPC-A
          LPRINT CHR$(27);it5r1o0x50y70b12345678901?\;
          EAN-13
          LPRINT CHR$(27);it5r1o0x100y70b123456789012?\;
          UPC-E
          LPRINT CHR$(27);it6r1o0x150y70b0123456?\;
          Codabar
          LPRINT CHR$(27);it9r1s0o0x00y100bA123456A\;
          Code 128 set A
          LPRINT CHR$(27);it12r1o0x00y120bCODE128A12345?\;
          Code 128 set B
          LPRINT CHR$(27);it13r1o0x00y140bCODE128B12345?\;
          Code 128 set C
          LPRINT CHR$(27);it14r1o0x00y160b;CHR$(1);CHR$(2);?\;
          ISBN(EAN)
          LPRINTCHR$(27);it130r1o0x00y180b123456789012?+12345\;
          EAN 128 set A
          LPRINT CHR$(27);it132r1o0x00y210b1234567890?\;
          LPRINT CHR$(12)
          END
     
    						
    All Brother manuals Comments (0)

    Related Manuals for Brother HL 7050N User Manual