System Parameters Programming System Parameters Programming [ 0] = Disables Relay 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. e-.=Each time the user presses a relay button, the LCD updates with the relay number and the function assigned. . .,‘;-“-:to it. Description The Triad-S has two relays on the BKSLJ that can be programmed to perform certain functions. These functions are loud bell, external page control, RAN Start, and CO Line control. RELAY 1RELAY 2 *n%...
Page 482
:2-60 System Parameters Programming Access Codes 2Enter a l-digit number for the baud rate: [I] = 150 Baud [2] = 300 Baud [3] = 600 Baud [4] = 1200 Baud [5] = 2400 Baud [6] = 4800 Baud ~ [7] = 9600 Baud 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description Port #l: First RS-232C port on the optional MISU board. Port #2: Second RS-232 port on the optional MISU board. By default, Port #l (MISU RS-232C), Port #2 (MISU RS-232) and Port #3 (Modem) baud rates are...
Page 483
System Parameters Programming Access Codes 2-61 DISA Access Code .s3w Programming Steps Q’,..“.S.,z.;&?--.
Page 484
2-62System Parameters Programming Access Codes Station Message Detail Recording (SMDR) Programming Steps 1Press FLASH and dial [21]. The following message displays: SDR TPE PNT 9;;; ;ORTNO LD 80 2To program SMDR features, use the flexible button(s) as defined in the following procedures. 3The ENABLE/DISABLE, TYPE, and PRINT features toggle on and off each time the button is pressed. The display updates with each toggle. 4After all entries are made, Press HOLD to save the entry. A confirmation tone is...
Page 485
System Parameters Programming Access Codes2-63 Description A call accounting device can be installed allowing the system to track calls by outside line number, number t-:=. .a c--2.: :. :sdialed, time of day, date, station that placed or received the call, and duration of the call. By default, SMDR is.~~~ disabled. Long Distance / All Calls Programming Steps 1Press the CALL TYPE flexible button (FLASH 21, button #2) to determine the type of calls to record. This feature toggles on and off each time the...
Page 486
2-64System Parameters Programming Access Codes Baud Rate Display Programming Steps The SMDR Baud Rate is programmed using Flash 15, Baud Rate Assignments. FLASH 21, button #4 returns an error tone when pressed. The LCD displays the current baud rate based on which port is assigned to the SMDR Port number. Description The Triad-S System provides SMDR output to the standard RS-232C connector on the optional MISU. The baud rate is displayed as 150, 300,600, 1200, 2400,4800, or 9600 baud. SMDR Port...
Page 487
System Parameters Programming Access Codes2-65 Weekly Night Mode Schedule Programming Steps 1Press FLASH and dial [22]. The following message displays: IDAY END START AUTOMON 0800 1700YESI Description The Triad-S System can be programmed so it is automatically placed into and out of night mode. A programmable weekly time schedule lets the system administrator preset the time the system goes into night mode, and the time night mode is removed on a daily basis, including weekend operation.AUTO...
Page 488
2-66System Parameters Programming Access Codes press the night key again. When the system is placed into night mode, CO line ringing follows the night ringing assignments and stations are governed by their respective night COS. The default times for automatic night mode are: Monday through Friday OS:00 17:00(Daytime operation 8:00 am to 5:00 pm) Saturday and Sunday ##:## ##:##(24-hour night-mode operation) ttAn entry of 0O:OO 23:59 indicates 24 hours of day mode oAn entry of ##;## ##;## directs the...
Page 489
System Parameters Programming Access Codes2-67 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. To scroll through the list: 1Press the NEXT flexible button (FLASH 23, button #18) to scroll up (next entry) or Press the PREV flexible button (FLASH 23, button #19) to scroll backwards (previous entry). Description Directory Dialing enables station users obtain a directory of station users and have the system dial the extension currently displayed. The Triad-S system...
Page 490
2-68System Parameters Programming Access Codes %i #114 de115 #lIoxzilNEXT ENTRYPREV ENTRYNEW ENTRY #117*rscria %@mzil%; To enter the Intercom number or System Speed Dial bin to associate to the name: 1Press the BIN/KM flexible button (FLASH 23, button #l). 2Enter a 3-digit station intercom number, a 3-digit System Speed Dial number, or a 3-digit Local Number/name Translation Table number. 100-l 31 = Triad-S Extension Numbers 020-099 = System Speed Number 600-799 = Local Number/Name Table 3Press HOLD to...