IntroductionFeatures and Capabilities PageWriter Trim Cardiograph Service Manual1-11 „Color or monochrome display as described in Table 1-2: „Export and import of ECG data in XML format to a TraceMasterVue ECG Management System by modem transmission, or by LAN or wireless LAN connection as described in Table 1-3: „Optional cart with convenient storage areas for supplies Capabilities „Downloads patient data from HIS with a barcode, magnetic card swipe, or Smart Card swipe „Stores ECGs on a removable PCMCIA card or USB memory stick „Transmits ECGs by FAX, PCMCIA-modem, LAN, or wireless LAN Table 1-2 PageWriter Trim Cardiograph Display by model Model Display PageWriter Trim I 40 x 2 character LCD PageWriter Trim II 640 x 480 monochrome LCD PageWriter Trim III 640 x 480 color LCD PageWriter Trim Rx 640 x 480 color LCD Table 1-3 PageWriter Trim ECG data transmission options by model Model Modem LAN WLAN PageWriter Trim I PageWriter Trim II ** ** PageWriter Trim III ** PageWriter Trim Rx ** Optional feature
IntroductionTour of PageWriter Trim Cardiographs 1-12PageWriter Trim Cardiograph Service Manual Tour of PageWriter Trim Cardiographs This section gives an overview of the exterior of the cardiograph, as well as the Patient Interface Module (PIM). For more information, see the PageWriter Trim Instructions for Use. PageWriter Trim I Cardiograph The following section shows front and rear views of the PageWriter Trim I cardiograph. Figure 1-1 PageWriter Trim I Cardiograph and Cart (Front View) APrinter paper drawerFWheel positioners BSlide out shelfGControl panel CPrinter paper/report storage slotHTrim Knob DOptional barcode reader in holderIPatient Interface Module (PIM) EStorage binJWheel brake A B D E FH G CI J
IntroductionTour of PageWriter Trim Cardiographs PageWriter Trim Cardiograph Service Manual1-13 CAUTIONAlways lock the wheel brake (J) when the cart is not in use. Press down on the wheel brake to set or to release the wheel brake. Figure 1-2 PageWriter Trim I Cardiograph (Rear View) WARNINGDo not connect a LAN cable connector to the PIM connector. Do not plug a telephone connector into the PIM connector. KReset buttonOBattery door LAC power cord connector PPIM connector MEquipotential post QSerial connector (not supported) NFuse door M N Q PO KL
IntroductionTour of PageWriter Trim Cardiographs 1-14PageWriter Trim Cardiograph Service Manual PageWriter Trim II, III, and Rx Cardiographs The following section shows front and rear views of the PageWriter Trim II, III, and Rx cardiographs. Figure 1-3 PageWriter Trim II, III, and Rx Cardiograph and Cart (Front View) AKeyboardGWheel positioners BPrinter paper drawerHDisplay screen CSlide out shelfITrim Knob DPrinter paper/report storage slotJPatient Interface Module (PIM) EOptional barcode reader in holderKWheel brake FStorage bin A B D E FH I J GC K
IntroductionTour of PageWriter Trim Cardiographs PageWriter Trim Cardiograph Service Manual1-15 CAUTIONAlways lock the wheel brake (K) when the cart is not in use. Press down on the wheel brake to set or to release the wheel brake. Figure 1-4 PageWriter Trim II, III, and Rx Cardiograph (Rear View) WARNINGDo not connect the LAN cable connector into the PIM connector. Do not plug a telephone connector into the PIM connector. Using the Cart Wheel Positioners and Brake The cart includes one wheel brake and two wheel positioners. Lock the wheel positioners at all times when using the cart. The wheel positioners keep the cart straight when moving forward or backward, or when turning corners. The wheel positioners also help the cart maneuver in tight spaces. LReset buttonRBattery door MPC card eject buttonSPIM connector NPC card slotTSmart Card Reader or USB memory stick connector OAC power connectorUBarcode reader or magnetic card reader connector PEquipotential postVSerial connector (not supported) QFuse door P Q SO R T UMN VL
IntroductionTour of PageWriter Trim Cardiographs 1-16PageWriter Trim Cardiograph Service Manual To use the cart wheel positioners and brake: 1 Align the front wheels so that they are straight. Step on both wheel positioners. Move the cart forward until the wheels lock into position. The cart will move forward or backward in a straight line. 2Step on the gray rear wheel brake to lock the cart wheels. The cart will not move. Step on the wheel brake again to unlock the wheels.
IntroductionGeneral Service Information PageWriter Trim Cardiograph Service Manual1-17 Patient Interface Module (PIM) The Patient Interface Module (PIM) is a hand-held device that connects to the cardiograph. The lead wires on the PIM attach to the electrodes placed on the patient. The exterior of the PIM is labeled for quick and easy lead identification. The PIM connects to the patient data cable and to the lead wires attached to the patient. See Figure 1-5 on the following page. For details about connecting the lead wires to the PIM, see the PageWriter Trim Instructions for Use. Figure 1-5 Patient Interface Module General Service Information Keep the following points in mind when servicing this product. Installation The PageWriter Trim cardiographs do not require installation by Philips field personnel. The cardiograph can be installed by the customer. See Chapter 1 “Getting Started” and 2 “Configuration” of the PageWriter Trim Instructions for Use or the PageWriter Trim Rx A C DB ALead wire labelingCLimb lead wires BPatient data cableDPrecordial (chest) lead wires
IntroductionUpgrades and Accessories 1-18PageWriter Trim Cardiograph Service Manual Instructions for Use for information on the proper setup and configuration of the cardiograph and cart system. NOTEThere are no configurable features for the PageWriter Trim I cardiograph. Upgrades and Accessories Upgrades and cardiograph accessories are available to add specific functionality to the device. The standard upgrades and available accessories are listed in Table 1-4 and in Table 1-5. Table 1-4 PageWriter Trim II, III, and Rx Cardiograph Accessories Part Number Description 989803129931 Barcode Reader 989803129941 Magnetic Card Reader 989803127331 PC Card 989803129961 Smart Card Reader 989803142041 Wireless LAN Card 989803129951 LAN PCMCIA Network Card 989803145331 USB Memory Stick 989803149571 Patient Cable Arm for Cardiograph Cart 989803127461 Modem Card (USA and Canada only) 989803138021 LAN Cable Table 1-5 PageWriter Trim Cardiograph Upgrades Part Number OptionDescription 860320 PageWriter Trim Cardiograph Cart 860302 PageWriter Trim II Cardiograph Upgrade Options B01 ECG Interpretation Upgrade Option B02 LAN Connectivity Upgrade Option 860303 PageWriter Trim III Cardiograph Upgrade Options B02 LAN Connectivity Upgrade Option B03 Wireless LAN Connectivity Options (802.11b compliant) 860299 PageWriter Trim Rx Cardiograph Upgrade Options B02 LAN Connectivity Upgrade Options
IntroductionPageWriter Trim II, III and Rx Token Label PageWriter Trim Cardiograph Service Manual1-19 Consult your sales representative, dealer, or distributor for the latest details. PageWriter Trim II, III and Rx Token Label Each cardiograph manufactured after January of 2006 has a token number assigned to it, and is shipped from the factory with a token label installed on the unit. See Figure 1-7 on page 1-20 for the location of the token label on the cardiograph. And, any cardiograph with installed software version A.01.00 or higher (regardless of manufacture date) must have an active token number assigned to it in order to operate. If upgrading from software version A.00.03 to A.01.01 or higher, or following a repair that necessitates upgrading the cardiograph software to version A.01.01 or higher, a token number is required in order to complete the software upgrade or repair procedure. For information on obtaining a token number in order to complete a software upgrade procedure, contact the nearest Philips Response Center. See “Contacting a Philips Response Center” on page 1-32 for a listing of contact telephone numbers. The token label contains the unique token number assigned to the cardiograph, and is affixed to the inside of the paper tray. To locate the token label, remove the paper tray from the cardiograph. The label is located on the far right side of the metal housing. Always ensure that the current token label is affixed to the cardiograph to help facilitate the servicing or troubleshooting of the unit. NOTEThere are no token numbers assigned to the PageWriter Trim I cardiograph. Figure 1-6 PageWriter Trim II, III, Rx Cardiograph Token Label Part Number OptionDescription B03 Wireless LAN Connectivity Options (802.11b compliant) 860304 PageWriter Trim Cardiograph External Battery Charger AXX Localization Code (refer to Table 1-11, “PageWriter Trim I, II, III and Rx Country and Region Options,” on page 1-23 for the correct localization option code for your country or region) B01 Additional Battery for the PageWriter Trim Cardiograph (any model) Table 1-5 PageWriter Trim Cardiograph Upgrades (continued)
IntroductionSupplies and Ordering Information 1-20PageWriter Trim Cardiograph Service Manual Figure 1-7 Location of Token Label on Cardiograph Managing Token Labels Each upgrade option available for purchase is enabled by a unique token number that is provided with the upgrade kit. Each time that a new option is purchased for the cardiograph, the new token number must be entered on the cardiograph, and the new token label must be affixed to the cardiograph in the specified location to facilitate future servicing and troubleshooting. For information on enabling and installing an optional upgrade, see “Upgrade Kit Installation” on page E-2. Supplies and Ordering Information The part numbers for all supplies for the PageWriter Trim I/II/III/Rx cardiographs are listed in this section. You can order all supplies on the World Wide Web at http://shop.medical.philips.com