    Have a look at the manual Panasonic Small Digital Business System 308/616 Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Section 400 
    Issue 1 JuIy 1990 S-DBS Programming Instructions 
    v1.0 
    0017#-(0 or l)# 
    SMDR TIMER - STARTING TIME DISPLAY FOR OUTSIDE CALLS 
    The start time for an outside caII appears on the display 15 seconds after the dial 
    signal is sent out. The 15-second default can be reset to 30 seconds. 
    The start time for an incoming calI appears on the display immediately after the 
    c~. is’ .answered.. -- -. 
    O#: 15 seconds 
    l#: 30 seconds 
    OOlS#-(0 or l)# 
    FLASH - REDIAL [AUTOMATIC) 
    The REDIAL key can automaticall 
    have been dialed and then redial x cut off an outside line after one or more digits 
    e same numbers again. 
    However, if the system is connected to a PBX. re-program for No Automatic 
    FLASH or the PBX wi.U go into ON-HOLD status when the REDLAL key is pressed. 
    O#: No automatic FLASH 
    . 
    A I4 . 
    0019#-(0, l-4)# 
    OUTSIDE LINE FLASH TIMER - OFF-HOOK (MANUAL) 
    Sets the timer to temporariIy release the outside line by pressing the FLASH or 
    REDLAL key. 
    O#: 0.5 second 
    l#: 1 second 
    2#: 1.5 seconds 
    3#: 2 seconds 
    4#: 3 seconds  
    						
    							S-DBS Progra.mming Instructions 
    v1.0 Section 400 
    Issue 1 July 1990 
    0020#-(Owl-4)# 
    SSD STORED OUTSIDE LINE FbISH TIMER 
    Sets the timer to temporarily release the outside line by pressing the FLASH key. 
    O#: 0.5 second 
    l#: 1 second 
    2#: 1.5 seconds 
    3% 2 seconds 
    4#: 3 seconds 
    DIAL PAUSE TIMER - OUTSIDE LINE 
    After making an outside line call and hanging up there is a timed pause before 
    you can dial out to make a second call. 
    0#: 0.75 second 
    l#: 1 second 
    2#: 2 seconds 
    3#: 4 seconds 
    4#: 6 seconds 
    5#: 8 seconds 
    6#: 12 seconds 
    7#: 16 seconds 
    _--..------ 
    0022#-(0.1~7)# - 
    OUTSIDE LINE GUARD TIMER - INCOMING MLLS 
    After answering an incoming call and hanging up there is a timed pause before 
    you can access another outside line. 
    O#: 0.75 second 
    l#: 1 second 
    2#: 2 seconds 
    3#: 4 seconds 
    4#: 6 seconds 
    5#: 8 seconds 
    6#: 12 seconds 
    7#: 16 seconds 
    c- ‘j 
    - .’ 
    __-- _---.- ____... --._- -----.~ -.... _- ~_ . 
    28  
    						
    							Section 400 
    Issue 
    1 July 1990 S-DBS Programn@@ns~c&~~~~ 
    V1.O 
    0023#-(0.1 or 2)# 
    PULSE DIAL MINIMUM PAUSE 
    Sets a pause between digits dialed during.puIse dialing. 
    0#: 640 ms 
    l#: 752 ms 
    0024#-m# 
    d 
    SWITCHING TIME FOR NIGHT MODE (AUTOMATIC) 
    You can set the system, so that it switches automaticaIIy from day mode to night. 
    Enter the time using the 12-hour system followed by 1 for AM. or 2 for P.M.: 
    8:02.P.M. = 08022 
    12:00kM.= 12001 
    ._ 11:59kM.=11591 
    CONF #: Remains in dav mode 
    HHMMN#: AutomaticaIIy switches to night mode. 01-12 (HH). 00-59 (MM). 00-59 
    (SS), N=l (A.M.) or 2 (P.M.) 
    0025#-(0 or l]# 
    TRANSFER ON-HOOK (AUTOMATIC) 
    An incoming call can be transferred to another extension by entering the &en- 
    sion number and replacing the receiver. The extension at the other end receives 
    an incoming call tone. 
    If automatic transfer is not programmed, see Operating Instructions, Section 
    700 for information on manual transfer. 
    O#: On-Hook transfer disable 
    l#: On-Hook transfer enable  
    						
    							S-DBS Progr amming Instructions 
    v1.0 Secaori ‘4330 
    Issue 1 July 1990 
    0026#-(0 or l)# 
    ONE-TOUCH KEY 
    You can dial stored telephone numbers and SPD codes by pressing a single key if 
    the system is programmed for One-Touch Call. 
    0#: One-touch call not possible 
    l#: One-touch call 
    0027#-(0 or l)# 
    __ _..---.. ..___ . 
    BACKGROUND MUSIC (BGM) d 
    O#: BGM disabled 
    l#: BGM enabled 
    0628#-(O.l-3)# 
    INFORMATION TONE FOR VOICE CALLING 
    Sets the information or splash tone for extensions called by voice. The tone is 
    sounded for 0.5 second before the caller’s voice is heard. 
    O#: Tone for voice call and Darrine call 
    l#: Tone for voice call 
    2#: Tone for paging call 
    3#: No information tone .--_ 
    0029#-(0 or l)# 
    CO SIGNAL - OFF-HOOK - ALERT TONE 
    An alert tone will sound to announce a second call. 
    O#: No alert tone 
    l#: Alert tone 
    30  
    						
    							Section 400 
    Issue 1 July 1990 S-DBS Programming Instnxtions 
    v1.0 
    0030#-(0 or l)# 
    STATION LOCKOUT ID CODE 
    Displays the ID code on an LCD telephone. 
    O#: ID code not disnlaved 
    l#: ID code displayed 
    0031#-(0 or l)# 
    SSD DISPLAY RESTRICTION (80-89) 
    4 
    Sets the system to display telephone numbers durin 
    an SSD call and REDIAL. If 
    SSD calls are programmed not to display, then redi 
    zf 
    not displayed either. ed telephone numbers are 
    O#: Number not disnlaved 
    l#: Number displayed 
    NOTE: AUTO (00-79) SSD numbers are always displayed. 
    0032#-(0’ or I)# 
    DATA SECURITY 
    Prohibits interrupting conversations or data transmissions. 
    0% Can interrupt 
    I#: Cannot intemrnt  
    						
    							S-DBS Prograxnmi.ng Instructions 
    v1.0 Section 400 
    Issue 1 July 1990 
    0033#-(0, P-7)# 
    EXTENSION HOLD RECALL TIMER 
    A recall warning tone sounds to indicate that an outside line ca.U has not been 
    answered within a specified time after being put on HOLD from an extension other 
    than the attendant’s nhone. 
    Set the hold recall timer at between 20-180 seconds. 
    O#: No recall 
    l#: Recall 20 seconds 
    2#: Recall 40 seconds 
    3#: Recall 60 seconds 
    a 
    _.----._ -__- ___---__ _- .-.. -. -. 
    6#: Recall 150 seconds 
    7#: Recall 180 seconds 
    0034#-(0, I-?)# 
    TRANSFER RECALL TIMER 
    If an outside line ca.U is not answered within a specified lime after being trans- 
    ferred. the call will revert back to the original extension. 
    Set the extension transfer recall timer at between 20-180 seconds. 
    O#: No recall 
    I#: Recall 20 seconds 
    2#: Recall 40 seconds 
    3#: Recall 60 seconds 
    4#: Recall 90 seconds 
    5#: Recall 120 seconds 
    6#: Recall 150 seconds 
    7#: Recall 180 seconds 
    32  
    						
    							Section 400 
    Issue 
    1 July 1990 S-DBS Programming Instruct+oln. 
    . 
    0035#-(0,1-5)# 
    SLT ON-HOOK (AUTOMATIC) DETECTION TIMER 
    Set the line flash on an SLT to either Line FLASH or disconnect when the hook 
    button is pressed lon er or less than the time set for a Iine 
    FLASH. (referred to as 
    the hooking operation. 
    4 
    No Detection Line Flash Disconnect 
    O#: No detection 
    l#: Less than 250ms 
    2#: Less than 250ms 
    3#: Less than 250ms 
    4#: Less than 250ms 
    5#: Less than 250ms 250 - 500 ms Over 500 ms 
    250 - 1000 ms Over 1000 ms 
    250 - 1500 ms Over 1500 ms 
    250 - 2000 ms Over 2000 ms 
    250 - 3000 ms Over 3000 ms 
    NOTE: Can only be set usin the POWER SETTING. See‘ 
    page 7 in this manu 3 for instructions. 
    0036f-(0 
    or 1)# 
    SLT OUTSIDE LINE HOLD 
    An outside Line caU on your extension can be put on System Hold or Exclusive 
    Hold. 
    O#: Svstem hold 
    l#: Exclusive hold 
    0037#-(0 
    or l)# 
    SLT INTERCOM CALL RING PATTERN 
    O#: Internal rim? signal nattem 
    I#: Same as incoming ca.II 
    signal pattern 
    . 
    33 
    ? 
    a -t  
    						
    							S-DBS Programming Instructions Section 400 
    v1.0 Issue 1 July 1990 ‘;.. -.. 
    0038#-(0, I-4)# 
    CPC SIGNAL TIMER - SLT EXTENSION LINE 
    The CPC signal is a disconnect signal sent to the SLT. 
    O#: No signal 
    l#: 0.25 second 
    2#: 0.50 second 
    3#: 0.75 second 
    4#: 1 second 
    0039#-(0 or l)# 
    DOOR BOX SPEECH PATH -- -- 
    The 308 system has 2 analog speech paths and the 616 system has 4 analog 
    speech paths. 
    door box only. One of these speech paths for each system can be set aside for the 
    O#: No door box sneech oath 
    l#: Door box speech path c ! 
    0040#-(0 
    or 1)# 
    SENSOR DETECTING SIGNAL 
    O#: Detects a make sisal 
    l#: Detects a break signal 
    0041#-(0 or l)# 
    SENSOR SIGNAL ALARM RING STOP 
    O#: Sensor detectine sifznal stons the alarm ring 
    l#: Picking up the receiver stops the alarm ring 
    . 
    ,.^ 
    c- .;  .I 
    34  
    						
    							Section 400 S-DBS Programming Instnxtions 
    Issue 1 July 1990 v1.0 
    0042#-(0 or l)# 
    MULTI-PURPOSE RELAY 2 FUNCTION 
    O#: Multi-DurDose relav 2 
    l#: Incoming ring signal 
    0043#-(0 or l)# 
    MULTI-PURPOSE RELAY 1 OPERATION 
    O#: Relav oDerated as Droprammed time 
    --.--. ----I# :’ Relay operate& continually 
    0044#-(0 or l)# 
    MULTX-PURPOSE RELAY 2 OPEMTION 
    ,,’ 
    O#: Relav oDerated as DroErammed time 
    l#: Relay operated continually 
    MULTI-PURPOSE RELAY 1 OPERATION TIMER 
    O#: 0.125 second 
    . 
    ~--_- 
    2#: 2 seconds 
    3#: 3 seconds 
    4#: 4 seconds . 
    5#: 5 seconds 
    6#: 6 seconds 
    7#: 7 seconds  
    						
    							S-DBS programming Instructions 
    v1.0 Section 400 
    Issue 1 July 1990 
    :_ 
    MULTI-PURPOSE RELAY 2 OPERATION TIMER 
    0% 0.125 second 
    l#: 1 second 
    2#: 2 seconds 
    3#: 3 seconds 
    4#: 4 seconds 
    5#: 5 seconds 
    6#: 6 seconds 
    7#: 7 seconds 
    . 
    36  
    						