Have a look at the manual Panasonic Small Digital Business System 308/616 Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
S-BBS Installation Instructions Section 300 v1.0 Issue 1 August 1990 DOOR BOX The door box associated with a customer-provided electrical door opener is usually mounted outside the building beside the front door. By pressing a button on the door box a visitor alerts the erson inside the building who controls the door opener by dialing an access code rom a programmed telephone. P 1. Connecting the Door Box CI -.-JZa.chdoor..box.connects two wires to a 25-pair extension cable. (See TABLE 2, page 15) Choose the appropriate wire gauge from the table below: - - TABLE 4. Wire Gauges 4;1 Wire Gauge 26 AWG, 24 AWG 22 AWG MaximumRange 230 Feet 370 Feet 590 Feet Resistance 20 a’ (Ohms) 20 a (Ohins) 20 s2 (Ohms) Figure 14 24 EXTENSION CONNECTOR
s S-DBS Installation Instructions v1.0 Section 300 Issue 1 August 1990 POWER FAILURE UNIT The Power Failure Unit (PFU) supports up to four CO PBXlines in case of power failure. The lines are switched directly to dedicated SLTs (type 500/2500 telephone) for incoming and outgoing calls. When power is restored the system will automatically.retum to normal service. e 1. Wall-Mounting Procedure (See Figure 15 on page 27) a) b) d 4 e) Remove the two screws from the PFU module and lift off the upper case. - Use the provided wood screw to mount the PFU onto the wall. The wood scr&v should stick out from the wall about 5/16th of an inch. Hook the PFU onto the wood screw and tighten the screw. Screw the wood screws into the holes at the bottom of the lower case. Cut the knockout parts from the bottom of the lower case with pliers and remove the clamp plate. 25
S-DBS Installation Instructions v1.0 Section 300 Issue 1 August 1990 .f-=. ! POWER FAILURE UNIT (continued) 2. Connecting the Power Failure Unit (PFU) (See Figure 15 on page 27) 1) Use the modular plugs to connect each trunk line from the CO/PBX to the ‘FROM COL (COLA to D)” jacks on the PFU. Up to four trunk lines can be Connected to the PFU. B 2) Connect the trunk lines from the TO COL (KSU)” jacks on the PFU to the “COL” port on the main unit by uslng - __-_- --.--- __- -----. th e modular plugs. - 3) Connect the EXT lines from the main unit to the ‘FROM SLT-LC (KSU)” jacks. 8 4) Connect each SLT line to the 7YO SLT” jacks on the PFU. 5) Connect two wires from the.power supply terminals on the PFU parallel to any EXT port. 6) Gather the wires back into the PFU and bring out through the underside of the PFU and attach the wires by clamp plate. (See (e) on Figure 15) Gf -- c .! . 26
section 300 Issue 1 August 1990 POWER FAILURE UNIT (continued) I/ co1 4 1 Connect to SLT lines %a S-DBS Installation Instructions v1.0 Connect to COL port jack Figure 15 27
?? - w e - S-DBS Installation Instructions Section 300 v1.0 Issue 1 August 1990 ~, ., i MUSIC-ON-HOLD (MOH) 1. Connecting Music Source to the MOH Connector The MOH RCA connector is the input terminal for music-on-hold (MOH). Connect the music source to the MOH connector on the main unit with an RCA jack. NOTE: If a tape recorder is connected to the MOH e connector, place the recorder five meters or more away tiom the main unit to prevent interference. a TABLE 5. MOH Xnput Impedance Y MOH terminal input impedance: 1.5k ohms maximuxn input level: 150mV maximum RCA Tape Recorder for music-on-hold 28 Figure 16 i :
Section 300 -.-. Issue.*xtigti3t-..lggo. EXTERNAL PAGING .-- _ %a S-DBS InstaUation Instructions v1.0 1. Connecting the Paging Speaker to the Amplifier The External Paging Amplifier (EPA) connector is the output terminal for external paging. a) Connect the EPA terminal to the amplifier input terminal. Q b) Connect the paging speaker to the amplifier output terminal. 1 EPA terminal output impedance: 600 ohms output level: -20dB EPA CONNECTOI; RCA / PIN PLUG I AMPLIFIER PACING SPEAKER F Figure 17
S-DBS Installation instructions Section 300 Vl .o Issue I August 1990 ._. .., ME.MO 30
clclclclcl Section 400 Issue 1 . ’ July 1990 S-DBS 3081616 (VI -0) Programming Small Digital Business System -mhlnstructi.ons _.__.__ Y6Y Panasonic DBS Small - For Models: UB-42010 0 42020 See other Section 400 for other Models Panasonk -.
/ ’ The information in this document is subject to change *thout notice and should not be construed as a commitment by the Panasonic Communications & Systems Company (PCSC). Furthermore, PCSC reserves the right, without notice, to make changes to equipment design as advance in engineering and manufacturing methods warrant. . . :. . ;: ) _ : .:’ :. . - . . , . .
Section 400 Issue 1 July 1990 S-DBS Programming instructions Vl .o FCC RULES AND REGULATIONS (Part 68) In compliance with the requirements of Part 68 of the FCC Rules and Regulations for connection of terminal equipment to the telephone network, and for your convenience, the following information is presented. Notifying the Telephone Company When connecting or disconnecting the terminal equipment to the telephone network, inform the telephone company of the particular line. (s) for connection. the FCC registration number and ringer equivalence number of the registered terminal equipment. ____-_. __ .---__ --_.-. .- _- _... d FCC Registration Numbers . Model Numbers Key System Hybrid System -- ! VB-42010 (DBS308) ACKUSA-61853~KF-E ACKUSA-61855~MF-E ‘....’ VB-42020 (DBS616) ACEUSA-6185~8X-E ACKUSA-6185~MF-E When enabling Pooled Trunk Access, inform the telephone company or a Panasonic service center of the MIT-E. FCC Registration number. According to FCC rules, Pooled Trunk Access is regarded as one of the distinguishing features of a PBX as opposed to a key telephone system. RINGER EQUWILENCE NUMBER (REN) 0.5 B The REN determin es the number of devices you may connect to your telephone line ancl SIU nave a~ tnose ~~~~he~-~~~-te~~p~e~b~~i~~c~ed. In most, but not all areas, the sum of the REWs of all devices connected to one line should not exceed five (5.0). You should contact your local telephone company to determine the maximum REN for your calling area. Service order code 9.OF Network address signaling code E Facility interface code 02LS2 (2 wire/Loop start) Required network interface code RJ25C Connection to a Party Line or Coin Operated Telephone Line . i ‘- Direct Connection to a Party Line or Coin Operated Telephone Line Is Prohibited. If you are on a party line, check with your local telephone company for further information. i *.. 111