    Have a look at the manual Panasonic Small Digital Business System 308/616 Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							fi?! 
    q* 
    S-DBS Installation Instructions Section 300 
    TT1 * __ ..__ -.----.--.. ---- 
    . ---Issue--l--August 1990 ,. 
    TABLE 2. Extension Connector for S-DBS 308/616 
    Station Cord 
    Green 
    Red 
    Black 
    Yellow 
    Zen 
    Black 
    Yellow 
    Green 
    Red 
    Black 
    Yellow 
    Green 
    Red 
    Black 
    Yellow 
    Green 
    Red 
    Black 
    Yellow 
    Green 
    Red 
    Black 
    Yellow 
    Green 
    Red 
    Black 
    Yellow 
    Green 
    Red 
    Black 
    Yellow  Color Cable Code Pin# EXT l-8 
    CUP 
    ; 
    ‘3 
    4 
    2 
    8’ 
    9 
    10 
    ‘12 
    :: 
    15 
    16 
    4 
    Ei 
    21 
    22 
    z 
    ;z 
    27 
    28 
    29 
    30 
    31 
    32  WH-BL 26 K-TEL 1 (24V) 
    BL-WH 
    1 K-TEL 1 GND 
    WH-OR 27 
    OR-WH 2 
    W-H-GN 28 
    GN-WH 3 
    WH-BR 29 
    BR-WH 4 
    30 
    5 
    RD-BL 
    31 
    BL-RD 
    6 
    RD-OR 
    32 
    OR-RD 
    7 K-TEL 4 (24V) 
    K-TEL 4 GND 
    RD-GN 33 
    GN-RD 8 
    RD-BR 
    34 
    BR-RD 
    9 K-TEL 5 (24V) 
    K-TEL 5 GND 
    35 
    10 
    BK-BL 
    36 
    BL-BK 
    11 
    BK-OR 
    37 
    OR-BK 
    12 
    38 
    13 SLT 6 (24V) 
    SLT 6 GND 
    gT& ; g$ 
    BK-BR 
    39 
    BR-BK 
    14 
    BK-SL 
    40 
    SL-BK 
    15 K-TEL 8 (24v) 
    K-TEL 8 GND 
    41 SLT 8 (24V) 
    16 SLT 8 GND 
    i WH-SL 
    SL-WH 
    _-- 
    ( ., 
    I 
    RD-SL 
    SL-RD 
    _  _____ .._ -_ 
    BK-GN 
    GN-BK 
    Y’L-BL 
    BL-YL 
    14  
    						
    							Section 300 
    Issue 
    1 August 1990 Qf 
    S-DBS Installation Instructions 
    VI.0 
    TABLE 2, Extension Connector for S-DBS 308/616 (continued) 
    Color Cable Code 
    YL-OR 
    OR-YL 
    Pin# EXT l-8 
    42 
    N/C 
    17 
    N/C CUP Station Cord 
    33 Green 
    34 Red 
    Y-L-GN 43 
    GN-YL 
    18 WC 
    WC 35. Black 
    36 Yellow 
    YL-BR 
    BR-YL 44 N/C 
    37 Green 
    19 N/C 38 
    Red 
    YL-SL 
    SL-YL 45 DHP 1 (24V) 
    39 - Black 
    20 DHP 1 GND 
    40 Yellow 
    VI-BL 
    46 
    RT ,-VT 21 DHF@2 (24V) 41 
    DHE2-GND~ 42 
    --. Green 
    Red . 
    -----.- -. 
    VI-OR 
    OR-VI WC 43 Black 
    2; ’ N/C 44 
    Yellow 
    VI-GN 
    GN-VI +24V to PFU 45 
    +24V to PFU ’ 46 Green 
    Red 
    VI-BR 
    BR-VI 
    VI-SL 
    SL-VI WC 47 Black 
    WC 48 Yellow 
    GND to PFU 49 - - 
    GND to PFU 50 - 
    NOTE: N/C = No connection  
    						
    							S-DBS Installation Instructions 
    v1.0 && . 
    Section 300 
    Issue 1 August 1990 / ,. . 
    *. 
    TABLE 2A. Extension Connector for S-DBS 616 
    Color Cable Code Pin# EXT 9-16 
    CUP Station Cord 
    Green 
    Red  WEBL 26 
    BL-WH 1 
    Black 
    Yellow  WH-OR 27 
    OR-WH 2 
    W-H-GN 28 
    GN-WH 3 Green 
    Red 
    -Black 
    Yellow  WH-BR 29 
    BR-WH 4 
    :+ 30 
    5 9 Green 
    10 Red  WH-SL 
    SL-VA3 
    Black 
    Yellow 
    Green 
    Red  RD-BL 
    BL-RD 
    ___-. -.- __-. _~. .~ -... -- - 31 
    6 
    RD-OR 32 
    OR-BD 7 
    Black 
    Yellow 
    RD-GN 33 
    GN-RD 8 
    RD-BR 34 
    BR-RD 9 Green 
    Red 
    RD-SL 
    SL-RD 35 
    10 Black 
    Yellow 
    BK-BL 36 
    BL-BK 11 21 Green 
    22 
    Red 
    BK-OR 37 
    OR-BK 12 23 Black 
    24 Yellow 
    BK-GN 38 25 Green 
    GN-BK 13 
    BK-BR 39 
    BR-BK 14 KiTELL5. (24v.e-.-26.---Red__- _... - 
    sLT l5 (24v Black 
    SLT 15 (GND) ;; Yellow 
    BK-SL 40 
    p& g g4&l 
    29 Green 
    SL-BK 15 - 30 Red 
    YL-BL 
    BL-YL 
    16 41 
    16 31 Black 
    32 Yellow  
    						
    							Pqg 
    Section 300 S-DBS Installation Instructions 
    Issue 1 August 1990. v1.0 
    ~“t”‘““^~o-It60nnector-.fo~--S-DBS-6-1~-(continued) 
    Color Cable Code Pin# EXT 9-16 
    CUP Station Cord 
    Green 
    Red 
    44 
    WC 37 
    19 
    WC 38 Black 
    YelIow 
    Green 
    Red Q 
    39 
    40 
    1 Black 
    Yellow 
    41 Green 
    42 Red 
    43 
    44 Black 
    Yellow 
    45 Green 
    46 Red 
    Black 
    Yellow 
    49 
    50  YL-OR 
    OR-YL 42 
    N/C 
    17 WC 
    Y-L-GN 
    GN-YL 43 WC 
    18 WC 
    YL-BR 
    BR-YL 
    YL-SL 
    SL-YL 
    WC 
    WC 
    N/C* 
    WC  VI-BL 46 
    BL-VI 21 
    VI-OR 47 
    N/C 
    OR-VI 22 WC 
    VI-GN 
    48 WC 
    GN-VI 23 N/C 
    VI-BR 
    BR-VI WC 
    WC 
    VI-SL 
    SL-vl WC 
    WC 
    NOTE: N/C = No connection  
    						
    							S-DBS Installation Instructions 
    v1.0 
    66 SPLIT BLOCK 
    308i616 
    K-TEL 1 
    N/C 
    K-TEL 2 
    N/C 
    K-TEL 3 
    SLT 3 
    K-TEL 4 
    SLT 4 
    K-%EL 5 
    SLT 5 
    K-TEL 6 
    SLT6 ’ 
    tlfi 
    K-TEL 2 
    SLT 9 
    K-TEL 10 
    SLT 10 
    K-TEL 11 ‘., 
    SLT 11 
    ‘K-TECL 12 
    SLT 12 
    K-TEL l? 
    SLT 13 
    K-TEL 14 
    SLT 14 
    K-TEL 7 
    SLT 7 
    K-TEL 8 
    SLT 8 
    N/C 
    N/C 
    N/C 
    DPH 1 
    DHP 2 
    N/C 
    +24 to PFU 
    N/C 
    GND to 
    PFU 
    Section 300 
    Issue 1 August 1990 
    ,- -. 
    : > 
    e 
    ._, 
    K-TEL 15 
    SLT 15 
    EC-TEL 16 
    SLT 16 
    N/C 
    N/C 
    N/C 
    N/C 
    N/C 
    N/C 
    N/C 
    N/C 
    N/C 
    c ‘I 
    Figure 10 
    18  
    						
    							Section 300 
    Issue 1 August 1990 %s S-DBS Installation Instructions 
    VI.0 
    SMDR INTERFACE CARD 
    Features Package “B” 
    The main unit is provided with an SMDR Interface Card connector which requires 
    Feature Package B, VB-42411. 
    Place the VB-42411 cartridge in the area on the KSU 
    marked “Feature Package”. (See Figure 11 below) 
    The Card provides an RS-232C port interface which is compatible with eustomer- 
    provided serial printers or ca.Il-accounting devices capable of generating detailed 
    reports for calI information, on time, duration and phone number. 
    p 
    c 
    L 
    . --- 25Pa;irA;mphenol 
    Connector 
    Extensions 1 - 8 a 
    Figure 11 
    19  
    						
    							S-DBS Installation Instructions 
    v1.0 
    a6 . 
    Section 300 
    Issue 1 August 1990 
    r-x 
    SMDR INTERFACE CARD (continued) 
    1. Installing the SMDR Card (See Figur~-ur~-og-pge 21) 
    --.-. __ .__ _.- 
    a) Place the SMDR card in the area on the main unit 
    marked “SMDR I/F’. Push the card forward to lock 
    it in place. 
    b) Use the ribbon cable attached to the SMDR card to 
    connect the card to the SMDR pin connector. 
    * 
    NOTE: When connecting a pri.r$er to this system, 
    see Table 3 below for co?‘rect pin configuration. 
    TABLE 3. Printer Connection 
    Q 
    PRINTER CONNECTION  
    						
    							Section 300 
    Issue 1 August 1990 
    SMDR INTERFACE CARD (continued) 
    Q 
    Figure 12  
    						
    							S-DBS Installation Instructions Section 300 
    v1.0 Issue 1 August 1990 
    DOORPHONE ADAPTOR INTERFACE CARD 
    The doorphone interface card supports two door boxes, provides alarm sensor 
    input terminals and accommodates two multi-purpose external relays. 
    Relay 1 has only one function: a multi-purpose relay that can be programmmed to 
    operate on either a continual or timed basis. 
    Relay 2 has m functions: multi-purpke and incoming ring signal. TheQmulti- 
    purpose function can be programmed to operate on either a continual or timed basis L 
    Relay 1 and 2 remain in the idle state until activated by a two-digit telephone code. 
    d 
    1. Installing the Doorphone Card (Se Figure 13 on page 23) 
    a) 
    b) 
    cl Slide the doorphone card to the right inside the 
    grooves on the main unit. ‘. 
    Use a ribbon cable to connect the doorphone card 
    to the DPH outlet on the main unit. 
    Connect wires for the sensor devices and relays to 
    the doorphone card. 
    ____.._.._.__ ..-. .~-. -.-~ ----.--.---- .------.- 
    22  
    						
    							Section 300 S-DBS Installation Instructions 
    Issue 1 August 1990 v1.0 
    DOORPHONE ADAPTOR INTERFACE CARD (continued) 
    DOORPHONE 
    +a 
    To 
    Relay 2 
    To 
    Relay 1 
    To 
    sensor 
    ( 
    -- 
    =3 r-u . 
    0 
    L 
    b 
    Y 
    Figure13 
    I 
    23 ‘, 
    i   