•Default: 8181 The following port numbers are unavailable since they are already in use. 20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 554, 995, 10669, 10670, 59000-61000 [Alarm deactivation time] Configure the duration that detections won't be made after an alarm is detected. For example, by using this function you can prevent E- mail from being sent too often when E -mail notifications are configured to be sent to cellular phones when an alarm is detected. 5s/ 10s/ 30s/ 1min/...
Page 102
Select an action to be taken when a terminal alarm 2 is detected from the following. This setting is available when “Terminal 2” is selected for “Alarm input” of the [Alarm] tab. • Off: Does not take any action even when a terminal alarm 2 is detected. • 1-256: If a previously registered preset position is selected, when a terminal alarm 2 is detected, the camera will move to that position. • Auto track: When a terminal alarm 2 is detected, the camera will start the auto tracking. • Patrol 2: When a...
Page 103
Click “Preset per sender >>” to open a separate window for setting preset positions for alarms. ( ® page 103) • Default: Off [Image compression rate upon alarm detection] Click “Image compression rate upon alarm detection >>” to display the setup menu that can configure the settings relating to image quality when an alarm occurs. The setup menu will be displayed in a newly opened window. ( ®page 104) [Alarm E-mail notification] Click “E-mail server >>” to display the setup menu that can configure the...
Page 104
[Close] button Click this button to close the “Preset per sender” setup menu. 10.2.2 Configure settings relating to image quality on alarm action Click “Image compression rate upon alarm detection” of “Camera action on alarm” on the [Alarm] tab of the “Alarm” page. ( ®page 101) [Image compression rate upon alarm detection] Select “On” or “Off” to determine whether or not to change the image quality of “Quality1” ( ®page 47) upon alarm detection. • On: Images will be transmitted with the image quality...
Page 105
10.2.3 Configure settings relating to alarm E-mail notificationsClick “E-mail server >>” of “Camera action on alarm” on the [Alarm] tab of the “Alarm” page. ( ®page 101) Refer to page 131 for information on configuration for these settings. Operating Instructions105 10 Configure the alarm settings [Alarm]
Page 106
10.2.4 Configure settings relating to FTP transmissions of alarm images Click “FTP >>” of “Camera action on alarm” on the [Alarm] tab of the “Alarm” page. ( ®page 101) Refer to page 134 for information on configuration for these settings. 106Operating Instructions 10 Configure the alarm settings [Alarm]
Page 107
10.2.5 Configure settings relating to Panasonic alarm protocol notification when an alarm occurs Click “Panasonic alarm protocol notification >>” of “Camera action on alarm” on the [Alarm] tab of the “Alarm” page. ( ®page 101) Refer to page 117 for information on configuration for these settings. Operating Instructions107 10 Configure the alarm settings [Alarm]
Page 108
10.2.6 Configure settings relating to HTTP alarm notification when an alarm occurs Click “HTTP alarm notification >>” of “Camera action on alarm” on the [Alarm] tab of the “Alarm” page. ( ® page 101) Refer to page 119 for information on configuration for these settings. 10.3 Configure the settings relating to the alarm output terminal [Alarm] Click the [Alarm] tab on the “Alarm” page. ( ®page 32, page 34) The settings relating to the alarm output terminal can be configured in this section. Alarm output...
Page 109
[Alarm output type] Select “Latch” or “Pulse” for the alarm output terminal at an alarm occurrence. • Latch: When an alarm is detected, the alarm output terminal will be in the state selected for “Trigger output” until the alarm occurrence indication button is clicked. • Pulse: When an alarm is detected, the alarm output terminal will be in the state to the “Trigger output” setting for the period set for “Pulse width”. When the alarm occurrence indication button is clicked, the alarm output terminal...
Page 110
[Close (Up to 5 characters)] Enter the name for “Close” of “AUX” on the “Live” page. • Unavailable characters: " & • Default: Close Note •AUX is a camera terminal that allows users to operate (Open/Close) arbitrarily from the “Live” page. For example, an operator can remotely control lights in a place where the camera is installed by connecting the terminal to the light controller. 10.5 Configure the VMD settings [VMD area] Click the [VMD area] tab on the “Alarm” page. ( ®page 32, page 34) The...