•The motion detection function is not the dedicated function to prevent thefts, fires, etc. We are not
responsible for any accidents or damages that may occur.
VMD area setting
[Select a preset position]
Select a preset position number to which the VMD area is to be set, and click the [Start] button.
When setting an area which is not at the preset position for the VMD area, select VMD activation in area  “except
the preset positions”.
VMD information addition [Information addition]
Select “On” or “Off”...

Page 112

IMPORTANT•When the settings are being configured on the setup menu, sometimes the VMD function may not work
correctly.
[Area]
When selecting a VMD area in the screen, it will be numbered as area 1.  (Subsequent areas will be numbered
in the order of selection.)
[All areas] button
When the [All areas] button is clicked, the whole area will become the VMD area, and “1(White)” will be
automatically applied to “Area”.
[Status]
Select “On” or “Off” to determine whether or not to perform video motion...

Page 113

[Detection sensitivity]
Adjust the sensitivity of motion detection in the VMD area using the slider. The settings can be configured for
each area individually. The larger the value is set, the higher the sensitivity level becomes.
The current value (1 (low) - 15 (high)) will be displayed below the slider.
• Default:  8
[Delete] button
Click the [Delete] button corresponding to the area to be deleted. The outline of the selected area will be
deleted.
[Light detection control]
Select “On” or “Off” to...

Page 114

10.6  Configure the settings relating to the audio
detection [Audio detection] Click the [Audio detection] tab on the “Alarm” page. ( ®page 32, page 34)
The settings relating to audio detection can be configured in this section. When the configured audio detection
level is exceeded, the alarm action will be performed.
The audio detection level can be adjusted in 10 levels.
In order to use the perform audio detection, audio settings must be configured. ( ®page 93)
IMPORTANT
•The alarm occurrence...

Page 115

Note•The volume level for when audio detection is performed can be changed in “Mic input volume
(Camera to PC)” on the [Audio] tab of the “Image/Audio” page. ( ®page 93)
[Audio detection level]
Select the level at which the camera determines that there is sound in the area around the camera when
detecting sound.
If you only want to detect loud sounds, raise the audio detection level; if you also want to detect quiet
sounds, lower the audio detection level.
Configure the audio detection level
Alarm...

Page 116

3.Adjust the  “Mic input volume  (Camera to PC) ” on the [ Audio] tab of the  “Image/Audio”  page as necessary.
( ® page 93)
→ The settings and the actual audio detection status are displayed on the bottom of the screen. If the
volume level goes above the audio detection level, a red bar, which indicates that sound has been
detected, is displayed.
If further adjustments are required, repeat from step 2.
Note
•“Audio detection”  can only be used when  “Mic input” or “Interactive(Full-duplex)”  is selected...

Page 117

10.7.1  Configure the settings relating to Panasonic alarm protocol
Panasonic alarm protocol notification[Panasonic alarm protocol]
Select “On” or “Off” to determine whether or not to provide notification by Panasonic alarm protocol.
• Default:  Off
Note
•Panasonic alarm protocol notifications are sent in order from “Address 1”. (Notifications are only sent
to addresses that have their “Alarm” checkboxs selected.)
[Additional alarm data]
Determine whether or not to send notifications for alarm area...

Page 118

[Destination port]
Select a destination port for the Panasonic alarm protocol from the following.
• Available range:  1 - 65535
• Default:  1818
The following port numbers are unavailable since they are already in use.
20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 995, 10669, 10670
[Retry times]
Select a retry time for the Panasonic alarm protocol.
• Available range:  0-30
• Default:  2
Destination of notification [Address 1] - [Address 8]
Enter the destination IP address or host name...

Page 119

10.7.2  Configure the settings relating to HTTP alarm notification
HTTP alarm notification[Address 1] - [Address 5]
Enter the destination IP address or host name of the HTTP alarm notification. Up to 5 destination server
addresses can be registered.
• Available characters:  Alphanumeric characters, the colon (:), the period (.), the underscore (_), and the
hyphen (-).
• Default:  http://
Example of entry:  “http://IP address of the HTTP server + : (colon) + port number” or “http://Host name:
(colon) +...

Page 120

[Notification data]
Enter the notification data to add after the destination HTTP server addresses set in [Address 1] - [Address
5].
• Available characters:  Alphanumeric characters
• Default:  /cgi-bin/comalarm.cgi?CMD=01
Note
•For “Address 1” to “Address 5”, a total of 256 characters can be entered for the address (including
“http://”) and “Notification data”.
• Make sure to enter a slash (/) as the first character for “Notification data”.
• If the HTTP alarm notification fails, information about the...