Panasonic Network Camera Wv Sud638 Operating Instructions
Have a look at the manual Panasonic Network Camera Wv Sud638 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
•Default: 8181 The following port numbers are unavailable since they are already in use. 20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 554, 995, 10669, 10670, 59000-61000 [Alarm deactivation time] Configure the duration that detections won't be made after an alarm is detected. For example, by using this function you can prevent E- mail from being sent too often when E -mail notifications are configured to be sent to cellular phones when an alarm is detected. 5s/ 10s/ 30s/ 1min/ 3min/ 5min/ 10min Default: 5s Note •The duration that alarm detections are not made can be managed for each type of alarm. For example, during the time when detections for command alarms are not made, detections for VMD alarm can be made. 10.2 Configure the settings relating to the camera action on alarm occurrence [Alarm] Click the [Alarm] tab on the “Alarm” page. ( ®page 32, page 34) The settings related to the camera action on alarm can be configured in this section. Camera action on alarm [Terminal alarm 1] Select an action to be taken when a terminal alarm 1 is detected from the following. This setting is available when “Terminal 1” is selected for “Alarm input” of the [Alarm] tab. • Off: Does not take any action even when a terminal alarm 1 is detected. • 1-256: If a previously registered preset position is selected, when a terminal alarm 1 is detected, the camera will move to that position. • Auto track: When a terminal alarm 1 is detected, the camera will start the auto tracking. • Patrol 1: When a terminal alarm 1 is detected, the camera will start the patrol. * If Patrol 1 is not registered it is not displayed on the screen. • Default: Off [Terminal alarm 2] Operating Instructions101 10 Configure the alarm settings [Alarm]
Select an action to be taken when a terminal alarm 2 is detected from the following. This setting is available when “Terminal 2” is selected for “Alarm input” of the [Alarm] tab. • Off: Does not take any action even when a terminal alarm 2 is detected. • 1-256: If a previously registered preset position is selected, when a terminal alarm 2 is detected, the camera will move to that position. • Auto track: When a terminal alarm 2 is detected, the camera will start the auto tracking. • Patrol 2: When a terminal alarm 2 is detected, the camera will start the patrol. * If Patrol 2 is not registered it is not displayed on the screen. • Default: Off [Terminal alarm 3] Select an action to be taken when a terminal alarm 3 is detected from the following. This setting is available when “Terminal 3” is selected for “Alarm input” of the [Alarm] tab. • Off: Does not take any action even when a terminal alarm 3 is detected. • 1-256: If a previously registered preset position is selected, when a terminal alarm 3 is detected, the camera will move to that position. • Auto track: When a terminal alarm 3 is detected, the camera will start the auto tracking. • Patrol 3: When a terminal alarm 3 is detected, the camera will start the patrol. * If Patrol 3 is not registered it is not displayed on the screen. • Default: Off [VMD alarm] Select an action to be taken when a VMD alarm is detected from the following. • Off: Does not take any action even when a VMD alarm is detected. • 1-256: If a previously registered preset position is selected, when a VMD alarm is detected, the camera will move to that position. • Auto track: When a VMD alarm is detected, the camera will start the auto tracking. • Patrol 1: When a VMD alarm is detected, the camera will start the patrol. * If Patrol 1 is not registered it is not displayed on the screen. • Default: Off [Audio detection alarm] Select an action to be taken when a sound alarm is detected from the following. • Off: Does not take any action even when a sound alarm is detected. • 1-256: If a previously registered preset position is selected, when a sound alarm is detected, the camera will move to that position. • Auto track: When a sound alarm is detected, the camera will start the auto tracking. • Patrol 1: When a sound alarm is detected, the camera will start the patrol. * If Patrol 1 is not registered it is not displayed on the screen. • Default: Off [Command alarm] Select an action to be taken when a command alarm is detected from the following. This setting is available when “On” is selected for “Command alarm”. • Off: Does not take any action even when a command alarm is detected. • 1-256: If a previously registered preset position is selected, when a command alarm is detected, the camera will move to that position. • Auto track: When a command alarm is detected, the camera will start the auto tracking. • Patrol 1: When a command alarm is detected, the camera will start the patrol. * If Patrol 1 is not registered it is not displayed on the screen. • Preset per sender: By registering the sender’s address for the command alarm and the preset position for that address, the camera will move to the preset position when an alarm is detected from the command alarm.102Operating Instructions 10 Configure the alarm settings [Alarm]
Click “Preset per sender >>” to open a separate window for setting preset positions for alarms. ( ® page 103) • Default: Off [Image compression rate upon alarm detection] Click “Image compression rate upon alarm detection >>” to display the setup menu that can configure the settings relating to image quality when an alarm occurs. The setup menu will be displayed in a newly opened window. ( ®page 104) [Alarm E-mail notification] Click “E-mail server >>” to display the setup menu that can configure the settings relating to E -mail notification when an alarm occurs. The setup menu will be displayed in a newly opened window. ( ®page 105) [Alarm image FTP transmission] Click “FTP >>” to display the setup menu that can configure the settings relating to FTP transmission when an alarm occurs. The setup menu will be displayed in a newly opened window. ( ®page 106) [Panasonic alarm protocol] Click “Panasonic alarm protocol notification >>” to display the setup menu that can configure the settings relating to transmitting Panasonic alarm protocol notifications when an alarm occurs. The setup menu will be displayed in a newly opened window. ( ®page 107) [HTTP alarm notification] Click “HTTP alarm notification >>” to display the setup menu that can configure the settings relating to transmitting HTTP alarm notifications when an alarm occurs. The setup menu will be displayed in a newly opened window. ( ®page 108) 10.2.1 Configure the settings relating to Preset per sender (“Preset per sender” setup menu) On the [Alarm] tab of the “Alarm” page ( ®page 101), click “Preset per sender” for “Command alarm”. The sender’s address for the command alarm, and the preset position for that address can be registered in this section. [Sender's address 1] - [Sender's address 8] Set the sender ’s IP address for the command alarm, and the preset position for that address. Up to 8 notification addresses can be set. [Auto track cooperation] checkbox: When the checkbox is selected, auto tracking starts after the direction of the camera moves to the preset position. Operating Instructions103 10 Configure the alarm settings [Alarm]
[Close] button Click this button to close the “Preset per sender” setup menu. 10.2.2 Configure settings relating to image quality on alarm action Click “Image compression rate upon alarm detection” of “Camera action on alarm” on the [Alarm] tab of the “Alarm” page. ( ®page 101) [Image compression rate upon alarm detection] Select “On” or “Off” to determine whether or not to change the image quality of “Quality1” ( ®page 47) upon alarm detection. • On: Images will be transmitted with the image quality selected for “Image quality upon alarm detection”. • Off: Does not change the image quality upon alarm detection. • Default: Off [Image quality upon alarm detection] Image quality can be changed upon an alarm occurrence. Select the image quality from the following. 0 Super fine/ 1 Fine/ 2/ 3/ 4/ 5 Normal/ 6/ 7/ 8/ 9 Low • Default: 5 Normal 104Operating Instructions 10 Configure the alarm settings [Alarm]
10.2.3 Configure settings relating to alarm E-mail notificationsClick “E-mail server >>” of “Camera action on alarm” on the [Alarm] tab of the “Alarm” page. ( ®page 101) Refer to page 131 for information on configuration for these settings. Operating Instructions105 10 Configure the alarm settings [Alarm]
10.2.4 Configure settings relating to FTP transmissions of alarm images Click “FTP >>” of “Camera action on alarm” on the [Alarm] tab of the “Alarm” page. ( ®page 101) Refer to page 134 for information on configuration for these settings. 106Operating Instructions 10 Configure the alarm settings [Alarm]
10.2.5 Configure settings relating to Panasonic alarm protocol notification when an alarm occurs Click “Panasonic alarm protocol notification >>” of “Camera action on alarm” on the [Alarm] tab of the “Alarm” page. ( ®page 101) Refer to page 117 for information on configuration for these settings. Operating Instructions107 10 Configure the alarm settings [Alarm]
10.2.6 Configure settings relating to HTTP alarm notification when an alarm occurs Click “HTTP alarm notification >>” of “Camera action on alarm” on the [Alarm] tab of the “Alarm” page. ( ® page 101) Refer to page 119 for information on configuration for these settings. 10.3 Configure the settings relating to the alarm output terminal [Alarm] Click the [Alarm] tab on the “Alarm” page. ( ®page 32, page 34) The settings relating to the alarm output terminal can be configured in this section. Alarm output terminal setup [Alarm output trigger] Select “On” or “Off” to determine whether or not to output the alarm signals to the alarm output terminal when an alarm is detected. • Default: Off 108Operating Instructions 10 Configure the alarm settings [Alarm]
[Alarm output type] Select “Latch” or “Pulse” for the alarm output terminal at an alarm occurrence. • Latch: When an alarm is detected, the alarm output terminal will be in the state selected for “Trigger output” until the alarm occurrence indication button is clicked. • Pulse: When an alarm is detected, the alarm output terminal will be in the state to the “Trigger output” setting for the period set for “Pulse width”. When the alarm occurrence indication button is clicked, the alarm output terminal will return to the normal state. • Default: Latch [Trigger output] Select “Open” or “Close” to determine whether to open or close the alarm output terminal when outputting the alarm signals. • Open: The alarm output terminal will open when outputting the alarm signals. (Normally close) • Close: The alarm output terminal will close when outputting the alarm signals. (Normally open) • Default: Close Note •When “Open” is selected, the alarm signal will be output for about 20 seconds when the power of the unit is turned on. [Pulse width] When “Pulse” is selected for “Alarm output type”, select an alarm output terminal duration from the following. • Available range: 1-120s • Default: 1s 10.4 Change the AUX name [Alarm] Click the [Alarm] tab on the “Alarm” page. ( ®page 32, page 34) The names of “AUX”, “Open” and “Close” on the “Live” page can be changed. AUX title [AUX (Up to 10 characters)] Enter the name for “AUX” on the “Live” page. • Unavailable characters: " & • Default: AUX [Open (Up to 5 characters)] Enter the name for “Open” of “AUX” on the “Live” page. • Unavailable characters: " & • Default: Open Operating Instructions109 10 Configure the alarm settings [Alarm]
[Close (Up to 5 characters)] Enter the name for “Close” of “AUX” on the “Live” page. • Unavailable characters: " & • Default: Close Note •AUX is a camera terminal that allows users to operate (Open/Close) arbitrarily from the “Live” page. For example, an operator can remotely control lights in a place where the camera is installed by connecting the terminal to the light controller. 10.5 Configure the VMD settings [VMD area] Click the [VMD area] tab on the “Alarm” page. ( ®page 32, page 34) The video motion detection areas can be set on this page. The VMD areas can be set up to 4 areas for each preset position (maximum 256 preset positions). When motion is detected in the set area, the alarm operations will be performed. The camera can be configured to take an alarm action even when the camera is not at the preset position. IMPORTANT •The alarm occurrence indication button ( ®page 10) will be displayed when motion is detected by the VMD function. • The alarm occurrence indication button will be displayed when receiving a command alarm. • Depending on the network environment, notification may be delayed even when “Real time ” is selected for “Alarm status update mode” on the [Basic] tab of the “Basic” page ( ®page 38). • After configuring the VMD area, the VMD area may move out of alignment when the JPEG/H.264 “ Image capture mode ” setting is changed. Make sure to check the VMD area after changing the “Image capture mode” setting. • If “Start” is selected after selecting a setting other than “Stop” for [Wiper] on the “Live” page during wiper operations, alarm operations will not be performed. The alarm occurrence indication button on the VMD area setting screen will also not be displayed. Stop wiper operations when configuring alarm settings. 110Operating Instructions 10 Configure the alarm settings [Alarm]