Panasonic Kx-T123210 Installation Manual
Have a look at the manual Panasonic Kx-T123210 Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
1. To protect the printed circuit board from static electricity, first discharge any body static by touching the metal board. 2. Loosen the screws to remove the metal board. 3. The location of the optional cards for the KX-Tl23210 is shown in the following. 0 Insert the optional card with holding a levers of the card into the KX-Tl23210 surely. DO not touch parts on the card. metal board Expansion Card I KX-Tl23270 KX-T123271 -- Expansion Card KX-T123270 KX-Tl23271 DSS Console Card (KX-Tl23241) DSS Console ii / Card KX-T1:3241 Screw Optional Cards Expansion Card KX-Tl23280 KX-Tl23281 Model No Description Reference Page Expansion Cards KX-Tl23270 This card adds 8 Extension’s 2-10 I KX-Tl23271 I This card adds 4 Extension’s, I KX-Tl23280 This card adds 4 CO’s. KX-Tl23281 This card adds 2 CO’s, DSS Console Card KX-Tl23241 The DSS Console requires the DSS Console Card for the operation. 2-14 2-9
To add eight extensions (jack number 17 through 24), use the optional expansion card KX-T123270. To add four extensions (jack number 17 through 20), use the optional expansion card KX-T123271. 1. Insert the expansion card KX-T123270 or KX-Tl23271 into the KX-Tl23210. 2. Insert connector to the KX-T123270 or KX-T123271 as shown at right. Cable Pin Numbers to be connected See page 2-l 1. 0 Mis-connection may cause the KX-T123210 to operate improperly. See “During Installation” page 6-l and “During Connection” page 6-2 before connecting. To Extensions (jack number 17 through 20, @ or 17 through 24 ) Connector type 50 pin (Amphenol 57JE series or the equivalent) Expansion/card KX-T123270 . jack number 17 through 24 KX-T123271 . jack number 17 through 20 ( ‘. To add-eight extensions (jack number 25 through 32), use the optional expansion card KX-Tl23270. To add four extensions (jack number 25 through 28), use the optional expansion card KX-Tl23271. 1. Insert the expansion card KX-T123270 or KX-Tl23271 into the KX-Tl23210. 2. Insert connector to the ‘KX-T123270 or KX-T123271 as shown at right. Cable Pin Numbers to be connected See page 2-l 1. l Mis-connection may cause the KX-T123210 to operate improperly. See “During Installation” page 6-l and “During Connection” page 6-2 before connecting. To Extensions (jack number 25 through 28, or 25 through 32 ) Connector type 50 pin (Amphenol 57JE series or the equivalent) Expansion card 2-10 KX-T123270 . . jack number 25 through 32 KX-T123271 . jack number 25 through 28
Cable Pin Numbers to be connected l Connection of the Proprietary Telephone l Connection of a Standard Telephone T:Tip Dl :Datal R:Ring D2:Data2 Connect the only pin number of “T” and “R”. 1 CONN. 1 CABLE CLIP NO. 1 2 3 4 5 6 7 a 9 10 11 12 13 14 15 16 17 ia 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 LC-1 LC-2 LC-3 LC-4 PIN COCOR 26 WHT-BLU T T R I- Dl JACK D2 No.1 7 R Dl JACK D2 No.25 T R Dl D2 T R Dl JACK D2 No.18 I T 1 R Dl JACK D2 No.26 T R Dl 02 I T 1 R Dl JACK D2 No.27 T R Dl D2 T R ’ Dl JACK D2 No.28 t T R Dl JACK D2 No.29 T R Dl D2 T R Di D2 T T T R R R Dl JACK Dl JACK Dl D2 No.22 D2 No.30 D2 T T R R Dl JACK Dl JACK D2 No.23 D2 No.31 T R Dl D2 T T R R Dl JACK Dl JACK D2 No.16 D2 No.24 -T-l-- R Dl JACK D2 No.32 T R Dl D2 T R Dl JACK D2 No.9 BLU-WHT WHT-ORN ORN-WHT WHT-GRN GRN-WHT WHT-BRN BRN-WHT WHT-SLT SLT-WHT RED-BLU JACK No.1 JACK No.2 JACK No.3 JACK No.4 JACK No.5 JACK No.6 JACK No.7 JACK No.8 27 2 28 3 29 4 30 5 31 T 1 R Dl JACK D2 No.10 T R Dl JACK D2 No.1 1 7 ORN-RED 33 RED-GRN a G RN-RED 34 RED-BRN 9 H BRN-RED 35 RED-SLT T 10 ’ SLT-RED 36 BLK-BLU 11 BLU-BLK 37 BLK-ORN 12 ORN-BLK 38 BLK-GRN 13 GRN-BLK 39 BLK-BRN 14 BRN-BLK 40 BLK-SLT 15 SLT-BLK 41 YEL-BLU 16 BLU-YEL 42 YEL-ORN 17 ORN-YEL 43 YEL-GRN ia GRN-YEL 44 YEL-BRN 19 BRN-YEL 45 YEL-SLT 20 SLT-YEL 46 VIO-BLU R Dl JACK D2 No.12 T R l- Dl JACK D2 No.13 T 1 R Di JACK D2 No.14 R Dl JACK D2 No.15 21 1 BLU-VI0 47 1 VIO-ORN Station wiring (2-pair twisted cabling): Modular Jack Connector Block Line code 27 2 28 Bridging Clips 2-11
To add four Central Office Lines (CO 9 through 12), use the optional expansion card KX-T123280. 1. 2. 0 Insert the expansion card KX-T123280 into the KX-Tl23210. Insert the modular plug of the telephone line cord (2-conductor wiring) into the modular jack on the KX-T123280. Mis-connection may cause the KX-Tl23210 to operate improperly. See “During Installation” page 6-l and “During Connection” page 6-2 before connecting. To Terminal Board or Modular Jacks from the Central Office (CO). RT 09 R : Ring 010 T : Tip 011 Vi ack (CO) Use 2-conductor wiring cord To add two Central Office lines (CO9 and COlO), use the optional expansion card KX-Tl23281. 1. 2. 0 Insert the expansion card KX-T123281 into the KX-Tl23210. Insert the modular plug of the telephone line cord (2-conductor wiring) into the modular jack on the KX-T123281. Mis-connection may cause the KX-T123210 to operate improperly. See “During Installation” page 6-l and “During Connection” page 6-2 before connecting. To Terminal Board or Modular Jacks e from the Central Office (CO). Use R : Ring T : Tip View of TEL Jack (CO) (KX-Tl23281) 2-conductor wiring cord 2-l 2
To add two Central Office lines (CO7 and 8), use the optional expansion card KX-T123280. Remove the card which is inserted into groove marked “C0.2”. Insert the expansion card KX-T123280 into the KX-T123210. Insert the modular plug of the telephone line cord (2-conductor wiring) into the modular jack on the KX-T123280. l Mis-connection may cause the KX-T123210 to operate improperly. See “During Installation” page 6-l and “During Connection” page 6-2 before connecting. To Terminal Board or Modular Jacks * from the Central Office (CO). RT R : Ring T :Tip View of TEL Jack (CO) co5 CO6 co7 CO8 Use 2-conductor wiring cord
Notes: To connect the optional DSS Console (KX-Tl23240 or KX-T61640), the optional DSS Console card (KX-T123241) is required. The DSS Console (KX-T123240 or KX-T61640) needs a paired Telephone (EMSS Proprietary Telephone) for proper operation, because the DSS console cannot work by itself. The EMSS Proprietary Telephone (such as KX-Tl23220, KX-Tl23230, KX-T123250, KX-T6I 620, KX-T61631, KX-T61630, KX-T61650, KX-T30820, KX-T30830, KX-T30850) is required as the paired telephone for dialing, storing, etc. Place the KX-T123240 or KX-T61640 and the paired telephone side by side on your desk. 1. Insert the DSS Console card (KX-T123241) into the KX-Tl23210. DSS Console Card KX-T123241 2. Insert the modular plug of the console line cord (4-conductor wiring) into the modular jack on the KX-Tl23241. b Console 1 Console 2 View of TEL Jack Up to 2 KX-T123240’s or KX-T6164O’s can be connected to the KX-T123210. Each console requires its own paired telephone. KX-Tl23240 or KX-T61640 can not be connected in pair with a standard telephone. The max. length of the console line cord (twisted cable) that connects the KX-Tl23210 and the DSS Console is shown below. 26 AWG: Under 460 feet 24 AWG: Under 750 feet 22 AWG: Under 1180 feet 4-conductor wiring is required for the DSS Console Pair Telephone DSS Console (EMSS Proprietary KX-Tl23240 Telephone) KX-T61640 I I Pair When using the KX-T123240 or KX-T61640, program must be done. Refer to “Paired Telephone Assignment for DSS Console” page 3-10. 2-14
For installing the doorphone, use the Optional Doorphone Adaptor (Use the KX-T30860D only). Installation of the doorphone Loosen the screw to separate the doorphone into 2 halves. install the lower case to the wall with 2 screws. l 2 Kinds of screws are included. Please choose according to your wall type. See the followings. Installation of the Doorphone Adaptor How to install the Doorphone Adaptor into the KX-Tl23210. 1. Connect a 4-conductor modular connector to the doorphone adaptor. doorphone adaptor (KX-T30860D) I 4-conductor wiring @m-----When the doorphone plate has been fixed to the wall. w-------When you wish to install the doorphone directly to the wall. : 3. Connect the wires from the terminal box to the screws located in the upper case. to the terminal box c (See page 2-16) 4. Secure both halves together and re-install the screw. 2. Install the doorphone adaptor into the adaptor compartment. , 3. After drawing a CPU Card, insert the adaptor connector into connector on the CPU Card (circuit board). Adaptor Connector Connector CPU Card 2-15
Doorphone Wiring (A) Connect the doorphohe adaptor to the terminal box using a 4-conductor modular connector. (B) Connect the wires of doorphone 1 to the red and green screws of the terminal box. (C) Connect the wires of doorphone 2 to the yellow and black screws of the terminal box. Doorphone Adaptor (KX-T30860D only)- Doorp hone ty_ % -4-conductor wiring is required. a Terminal 1 (KX-T30865) Doorphone 2 (KX-T30865) t e The max. length of the telephone line cord (twisted cable) that connects the KX-T123210 and the doorphone (KX-T30865) is shown below. 26 AWG: Under 230 feet 24 AWG: Under 370 feet 22 AWG: Under 590 feet 2-16
If the telephone you are using with the KX-Tl23210 is polarity sensitive. 1. Connect all extension wiring to the KX-Tl23210 2. Confirm that dialing can be done from all the extensions using a tone telephone. 3. If a dialing can not be done, the polarity between the extension and the KX-Tl23210 must be reversed. KX-Tl23210 Central Office Line 4. Set the Power Switch on the KX-Tl23210 to the OFF-position. 5. Connect all Central Office (CO) Lines. 6. Confirm that dialing can be done on the following extensions using a tone telephone. Extension of jack number l--CO1 Extension of jack number 2--CO2 Extension of jack number g--CO.5 Extension of jack number lo--CO6 Extension of jack number 17--CO9 Extension of jack number 18--CO10 7. If dialing can not be done, the polarity between the KX-Tl23210 and the Central Office Line must be reversed. KX-Tl23210 Central Office Line 8. If any extension is changed or replaced, repeat these procedures (from step 1 through step 7). Car type batteries which are customer supplied is available as a back up power supply to the KX-Tl23210 to operator all the features in the event of power failure. For connecting car type batteries, use the Optional Battery Adaptor KX-A26. 1. Connect the Battery Adaptor KX-A26 to car type batteries. 2. Connect the Battery Adaptor KX-A26 to the Battery Backup Connector of the KX-Tl23210. KX-Tl23210 Car type batteries ttery Backup Connector 0 Consisting of two 12 VDC (24 VDC) o 16 amp / hour maximum rating 2-17
Serial Prihter Make cables so that the printer will be connected to the KX-Tl23210 as shown in the chart. Cables must be shielded and the maximum length is 6.5 feet. Connection Chart : KX-T123210 RS-232C Printer RS-232C 0 Panasonic data terminal ; KX-D4910D, KX-D4911, KX-D4920, KX-D4985, etc. If you connect this unit to a Panasonic Data Terminal, the Communication Parameter Transmit XON / XOFF on the Data Terminal must be set to the “YES” position. For further details, see the Operating Instructions of the Data Terminal. Serial Interface ( RS-232C ) When using special accessories such as cable, the user should use those specified in this installation manual to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules. The pin configuration of EIA (RS-232C) connector is as follows. Pin Number Signal Name Circuit Type EIA CCITT 1 2 FG Frame Ground AA 101 TXD Transmitted BA 103 Data 3 4 RXD Received Data BB 104 RTS Request To CA 105 Send CTS Clear To Send CB 106 DSR DataSet Ready CC 107 SG Signal Ground AB 102 DCD Data Carrier CF 109 Detect 20 DTR DataTerminal CD 108.2 Ready I 2-18