Panasonic Kx-T123210 Installation Manual
Have a look at the manual Panasonic Kx-T123210 Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
INSTALLATION MANUAL ELECTRONIC MODULAR SWITCHING SYSTEM KX-T123210 EASA-PHONE Panasonic Please read this manual before connecting the KX-T123210
Thank you for purchasing the Panasonic Model KX-T123210, Electronic Modular Switching System (EMSS). SYSTEM COMPONENT Service unit Telephone Optional equipment Model No. Description KX-Tl23210 Electronic Modular Switching System KX-T123220 EMSS Proprietary Telephone (12CO’s) KX-Tl23230 EMSSProprietaryTelephonewithLCD(12CO’s) KX-Tl23250 EMSSProprietaryTelephone (12CO’s) KX-T61620 EMSSProprietaryTelephone (6CO’s) KX-T61630 EMSSProprietary Telephone with LCD (6CO’s) KX-T61631 EMSS Proprietary Telephone with LCD (6 CO’s) KX-T61650 EMSSProprietaryTelephone (6CO’s) KX-T30820 EMSS ProprietaryTelephone (3CO’s) KX-T30830 EMSSProprietaryTelephonewithLCD(3CO’s,8DSS’s) KX-T30850 EMSSProprietaryTelephone (3CO’s) KX-Tl23240 DSS Console (32 DSS’s, 16 Feature buttons) KX-T61640 DSS Console (16 DSS’s, 16 Feature buttons) KX-T123241 DSS Console Card KX-Tl23270 Expansion Card (up to eight extension lines) KX-T123271 Expansion Card (up to four extension lines) KX-T123280 Expansion Card (up to four CO lines) KX-T123281 Expansion Card (up to two CO lines) KX-T30860D(only) Doorphone Adaptor KX-T30865 Doorp hone KX-T30890 Headset KX-A26 Battery Adaptor 1-l
NOTIFY THE TELEPHONE COMPANY Installation must be performed by a qualified professional installer. Notify the Telephone Company Before connecting this equipment to any telephone, call the telephone company and inform them of the following : Telephone numbers to which the system will be connected ........................................................ Make ............................................................................................................................................ Panasonic Model ........................................................................................................................................ KX-T123210 -’ FCC Registration No. .......................................................................................... ACJ 96 N-19294-M F- E Ringer Equivalence -- ............................................................................................................................. 0.4B Facility Interface Code ..................................................................................................................... 02LS2 Service Order Code ............................................................................................................................. 9.OF Required Network Interface Jack ..................................................................................................... RJ 11 Present FCC Regulations prohibit connecting this unit to a party line, or to a coin operated telephone. Please read the section on “Telephone Company and FCC Requirements and Responsibilities” on page 6-8. The serial number of this-product may be found on the label affixed to the side of the unit. You L should note the serial number of this unit in the space provided and retain this book as a permanent 1 record of your purchase to aid in identification in the event of theft. I MODEL NO . : KX-Tl23210 SERIAL NO. : For your future reference DATE OF PURCHASE NAME OF DEALER DEALER’S ADDRESS l-2
PROGRAMMING FEATURE OUTLINE E- Date and Time . . . . . . . . . , . . . . System Speed Dialing . . . . . . . . Extension Number . . . . . . . . . . Operator . . . . . . . . . . . . . . . . . . DSS Console . . . . . . . . . . . . . . . . k Day/Night Service ................. Call Hunting ..................... Toll Restriction ................... Hold ........................... Transfer Recall Time .............. Call Forwarding Starting Time ....... Pickup Dial Delay Time ............ CO-to-CO Duration Time Limit ...... Station Message Detail Recording ... Duration Time Count Start Mode .... External Paging Access Tone ....... CO Connection ................... Dial Mode (DTMF/Pulse) ........... Host PBX Access Codes ........... Trunk Group ..................... Outward Dialing .................. Ringing ......................... Delayed Ringing .................. CO Direct In Line ................. Pause Time ...................... Hookswitch Flash Timing ............ Calling Party Control Signal ......... Disconnect Time .................. Extension Group .................. Service Class of Toll Restriction ..... System ---E E I t ---E Extension t ) Doorphone ” ” ” ’ Extension Name . . . . . . . . Account Code . . . . . . . . Call Transfer/Call Forwarding Executive Override . . . . . Do not Disturb Override . . . . . . . . . . . . . . . . . . . . . . . . . . . ........ ........ ....... ........ ........ ........ Call on Hold for Standard Telephone . System Data Clear . . . . . . . . . . . . Page 3-4 3-5 3-8 3-9 3-10, 3-11 3-l 2 3-l 5 3-l 7 3-25, 3-26 3-27 3-28 3-29 3-30 3-31 3-40 3-41 3-42 3-43 3-45 3-46 3-47 3-49 3-52 3-54 3-59 3-60 3-61 3-62 3-63 3-64 3-68 3-70 3-71, 3-72 3-73 3-74 3-75 3-77 3-78 . , 1-3
TABLE OF CONTENTS Quick Reference Name and Location’::::::::::::::::::::::::::::::::::: Installation Connection ‘::::::::::::::::::::::::::::::::::::::::::: Central Office Line Connection (CO1 through 6) ............. Extension Connection .................................. Optional Cards Installation ............................... Extension Connection Option ............................ Central Office Line Connection Option ..................... Optional DSS Console Connection (KX-T123240/KX-T61640) . Optional Doorphone Connection .......................... Polarity Sensitive Telephone Connection ................... Battery Connection ................ Printer Connection ................ .................... Paging Equipment ................ .................... External Music Source ............. .................... Programming Programming Instructions .......... Example of Programming .......... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Feature Date and Time Setting ............. . . . . . . . . . . . . . . . . . . . System Speed Dialing Entry ........ has not been stored Extension Number Assignment ...... (see page) Operator Assignment .............. has not been stored Paired Telephone Assignment for DSS Console ............ Console 1 : Jack no. 01 Console 2 : Jack no. 02 Automatic CO Hold Using DSS Button ... Automatic Hold Day/Night Service Mode Switching of Service Mode ....... manual mode Starting Time .................. day service 9 : AM night service 5 : PM Call Hunting Setting ....................... Disable Hunting Type. .................. Terminate . Toll Restriction .................... Area Type Selection ............ CO Operator Call-Boundary Class. .. Toll Restriction of Speed Dialing . Exchange Code Selection ....... Area Code Entry For Class 3 .... 1-4 . . . . . . . . . . . . . . . . . . . . . . . Type A Class 1 Restriction has not been stored has not been stored . . . . . . . . . . . . . . ’ ’ ’ . . . . l-9 2-l 2-l 2-5 2-7 2-8 2-9 2-l 0 2-l 2 2-l 4 2-l 5 2-l 7 2-l 7 2-l 8 2-20 2-20 3-l 3-3 3-4 3-5 3-8 3-9 3-l 0 3-l 1 3-l 2 3-13 3-l 5 3-l 6 3-l 7 3-l 8 3-19 3-20 3-21 3-22
Exchange Code Entry For Class 5 Exchange Code Entry For Class 7 . Hold Time Reminder . . . . . . . . . Hold Recall Time Set .............. Transfer Recall Time .............. Call Forwarding Starting Time ...... Pickup Dial Delay Time ............ CO-to-CO Duration Time Limit ...... has not been stored has not been stored after 3 minutes after 30 seconds after 30 seconds 3 rings delay dial after 3 seconds 10 minutes Station Message Detail Recording (SMDR) . . . . . . . . . RS-232C Communication Parameters . . . . . . . . SMDR Parameters . . . . Incoming/Outgoing Call Selection for printing . . Secret Speed Dial/One Touch Dial Printing . . . . . . System Data Dump . . . Duration Time Count Start Mode . . . . . . . . . . . External Paging Access Tone . . . . . . has been added Outside Line Feature CO Connection Assignment . . . . . . Dial Mode (DTMF/PuIse) DTMF/Pulse Selection Pulse Speed Selection DTMF mode Low speed Host PBX Access Codes Assignment.. has not been stored Trunk Group Assignment (see page) Flexible Outward Dialing Assignment Day Mode . . . . . . . . . . . . . . . . . . . . . Night Mode . . . . . . . . . Flexible Ringing Assignment Day Mode . . . . . . . . . . . . . . . . . . . . . Night Mode . . . . . . . (see page) (see page) Incoming : ON Outgoing : ON No Printing All parameters 5 seconds after dial Connect all CO’s have been assigned on all extensions all CO’s have been assigned on all extensions all CO’s have been assigned on all extensions all CO’s have been assigned on all extensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23 3-24 3-25 3-26 3-27 3-28 3-29 3-30 3-31 3-32 3-35 3-36 3-36 3-37 3-40 3-41 3-42 3-43 3-44 3-45 3-46 3-47 3-48 3-49 3-51 : . . ! i :’ : 1-5
Delayed Ringing Assignment Day ‘Mode . . . . . . . . . . . . . . . Night Mode . . . . . CO Direct In Line Assignment Day Mode . . . . . . . . . . . . . . . . . . . . . Night Mode . . . . . . . . . . Pause Time Assignment . . Hookswitch Flash Timing . . . . . Calling Party Control (CPC) Signal . Disconnect Time . . Extension Feature Extension Group Assignment . . . Day Mode . . . . . . . . . . . . . . . . . . . . . Night Mode . . . . Extension Name . . . . . . . . . Account Code input Mode . . . . . Call Transfer to Outside Line . . Call Forwarding to Outside Line . Executive Override . . . Do not Disturb Override . . . . . . Class 1 Class 1 has not been stored Option Disable Disable Disable Disable ...... 3-64 ...... 3-66 ...... 3-68 ...... 3-70 ...... 3-71 ...... 3-72 ...... 3-73 ...... 3-74 Doorphone Feature Ringing Assignment from Doorphone Day Mode . . . . . . . . . . . . . . . . . . . . . Night Mode . . . . Call on Hold for Standard Telephone . . . . . all extensions can be received call all extensions can be received call Hold-l mode System Data Clear . . . . . . . . All parameters ...... 3-75 ...... 3-76 ...... 3-77 ..... 3-78 Example of Flexible CO Button . . . . . . . . . . . . . . . . . . . . . . . . . 3-81 lmmdtly lmmdtly Normal mode Normal mode 3.5 seconds 600 m seconds 400 m seconds 1.5 second Service Class Assignment of Toll Restriction all CO’s have been assigned on group 1 ...... 3-52 ...... 3-53 ...... 3-54 ...... 3-57 ...... 3-59 ...... 3-60 ...... 3-61 ...... 3-62 . . . . 3-63 1-6
Operation for EMSS Proprietary Telephone (KX-T123230, KX-T123220, KX-Tl23250, KX-T61631, KX-T61630, KX-T61620, KX-T61650, KX-T30830, KX-T30820, KX-T30850) Making Calls Inter Office Calling (Intercom) . . . . . . . . . . . . . . . . . . . 4-1 Outward Dialing . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2 Speed Dialing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 One Touch Dialing . . . . . . . . . . . . . . . . . . . . . . . 4-4 Calling Doorphone . . . . . . . . . . . . . . . . . . . . . . 4-6 Operator Call . . . . . . . . . . . . . . . . . . . . . . . 4-6 Distinctive Dial Tone . . . . . . . . . . . . . . . . . . . . . . . 4-6 When a Line is Busy Automatic Call Back Busy (Camp-On) Last Number Redial . . . . . . . . . . Busy Station Signaling . . . . . . . . Executive Override (Barge-In) . . Receiving Calls Answer . . . Automatic Answer-Intercom Dial Call Pickup . . . Directed Call Pickup . . . . . Call Park . . . Doorphone . . . . . . . . . . Distinctive Ring Tone . . . . . . . . . . . . . . . . .................... ...... 4-7 .................... ...... 4-8 .................... ...... 4-8 .................... ...... 4-9 . . . . . . . . . . . . . . . . . . . . . . . . . 4-10 . 4-10 . 4-11 . . 4-l 1 . . 4-12 . . . 4-13 . . 4-13 While Having a Conversation Call on Hold ................................................. 4-14 Call on Exclusive Hold ......................................... 4-15 Conference .................................................. 4-16 Privacy Release .............................................. 4-17 Call Transfer-To Extension ...................................... 4-l 8 Call Transfer-To Outside Line ................................... 4-19 Call Waiting .................................................. 4-20 Call Splitting-Between CO and Intercom .......................... 4-21 Call Splitting-Intercom .......................................... 4-22 Mute Operation ............................................... 4-22 Switching between Using Handset and Hands-free .................. 4-23 Paging All Extensions . . . . . Group . . . . . . . . . . . . . . . . External . . . . . . . . . Paging And Transfer . Answer . . . . . ...... ...... ...... ...... Use of Other Features Call Forwarding-All Calls/Busy or Call Forwarding-To Outside Line Dial Call Pickup Deny . . . Do Not Disturb . . . . . . Do Not Disturb Override . . . Saved Number Redial . . . No Answer . ............ ............ ............ ............ ............ .............. .............. .............. .............. .............. . . . . . . . . . . . . . ...... 4-23 ...... 4-24 ...... 4-24 ...... 4-25 ...... 4-25 . . . 4-26 . . . 4-28 . . . . 4-29 . . . 4-30 . 4-31 . . . . 4-31 1-7
Executive Override Deny ..................................... Switching to Tone Alerting .................................... Background Music .......................................... Absent Message Capability ................................... Message Waiting ........................................... Flexible Night Service ....................................... External Feature Access ..................................... Account Code .............................................. Data line Security ........................................... Call Waiting Tone-From CO/Extension Deny ...................... DSS Console (KX-T123240 or KX-T61640) ...................... Pulse/Tone Conversion ...................................... Station Feature Clear ....................................... Busy Lamp Field ........................................... Power Failure Transfer ....................................... Duration Time of Call Display ................................. Lockout ................................................... Mixed Station Dialing ........................................ . 4-32 . 4-33 4-33 4-34 . 4-36 . 4-37 . 4-38 4-39 . 4-41 . 4-42 . 4-43 . 4-45 . 4-45 . 4-46 . 4-47 . 4-47 . 4-47 4-47 Station Programming One Touch Access for System Features Auto CO Hunting .................. Automatic Answering Selection ....... Flexible CO Button ................. Intercom Voice Alerting Mode ........ Flexible DSS Button ................ CO Line Ringing Selection .......... Date and Time Setting .............. Station Number Check .............. F3-One Touch Button Mode Selection . Call Waiting Tone Selection ......... Station Program Clear .............. . . . . 4-48 . 4-49 . 4-51 . . . . 4-53 . . . . 4-56 . . . 4-57 . . 4-58 . . 4-59 . . . . 4-60 . . . 4-60 . . . 4-61 . . . 4-61 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation for a Standard Telephone Making Calls ........................ When a Line is Busy ................. Receiving Calls ...................... While Having a Conversation .......... Paging ............................. Use of Other Features ................ . . 5-l . . 5-2 . . . . . 5-3 . . . . 5-4 . . . . 5-7 . . . 5-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Troubleshooting ...................... Table of System Features .............. List of Tones ......................... List of Ring Tones .................... Specification ......................... Telephone Company and FCC Requirements and Responsibilities Others .............................. Warranty ............................ Servicenter List ....................... Phone Number Directory ............... Programming Table ................... Index ............................... . . . . . . . . . 6-1 . 6-5 6-6 6-6 6-7 , . . . . . . . . . . . . . . . . . . . 6-8 . 6-9 . 6-10 . . 6-11 . 7-l . 7-3 . . 7-26 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
INSTALLATION (Quick Reference) (See page 2-2) For earth ground, see page 2-2. (See page 2-3) 1. Place the templet (included) on the wall to mark the 3 screw positions. 2. Install the 3 screws into the wall. 3. Hook the unit on the screw heads. b . _ . . . + - . . . . . . . . . --__A templet El b___ ____* (See page 2-4) 1. Unscrew the front cover of the unit. There are four screws. 2. Open the front cover in the direction of the arrow @. (See page 2-7) modul Use 2. wiring CC6 l To Terminal Board or Modular Jacks from the Central Office (CO). (See page 2-8) To Extensions (jack number 9 through 16) To Extensions (jack number 1 through 8) (See page 2-4) Proprietary Telephone 26 AWG: Under 460 feet 24 AWG: Under 750 feet Twisted cable 22 AWG: Under 1180 feet 1 Standard Telephone 26 AWG: Under 2290 feet 24 AWG: Under 3700 feet Twisted cable 22 AWG: Under 5900 feet 1 I