Page 461

Chapter 1. System Programming (FFl)Section 400-Programming
Red Alarm Counter
Software Version:WC-6 Version 4.0 or higherAddress: Master Cabinet: 
FFl 8# 4# 4# 3# 3# (019000)#
Slave Cabinet:FFl 8# 4# 5# 3# 3# (O-9000)#
DescriptionDetermines how many red alarms occur before a Red Alarm FF key is lit.
The FF key lights when the counter exceeds the specified number within a
24-hour period.
For instructions on programming 
Tl alarm keys, see the TI Reference
Manual (Section 500).
Programming
FFl 8# 4# (4 or...

Page 462

Section 400-ProgrammingChapter 1. System Programming (FFl)
Loss of Signal Counter
Software Version:CPC-B Version 4.0 or higherAddress: Master Cabinet: 
FFl 8# 4# 4# 3## 4# (O-9000)#
Slave Cabinet:FFl 8# 4# 5# 3# 4#I (0-9000)#
DescriptionDetermines how many instances of loss of signal must occur before a Signal
Loss Alarm FF key is lit.Signal loss occurs when the incoming 
Tl signal is
not received for more than 150 ms. The FF key lights when the counter
exceeds the specified number within a 
24-hour...

Page 463

Chapter 1. System Programming (FFl)Section 400-ProgrammingSync Loss Counter
Software Version:CPC-8 Version 4.0 or higherAddress: Master Cabinet: 
FFl 8# 4# 4# 3# 5# (O-9000)#
Slave Cabinet:FFl 8# 4# 5# 3# 5# (019000)#
DescriptionDetermines how many instances of sync loss must occur before a Sync Loss
Alarm FF key is lit. The FF key lights when the counter exceeds the specified
number within a 24-hour period.
For instructions on programming 
Tl alarm keys, see the Tl Reference
Manual (Section 500)....

Page 464

Section 400-ProgrammingChapter 1. System Programming (FFl)Yellow Alarm Counter
Software Version:CPC-B Version 4.0 or higherAddress: Master Cabinet: 
FFl 8# 4# 4# 3# 6# (O-9000)#
Slave Cabinet:FFl 8# 4# 5# 3# 6# (0-9000)#
DescriptionDetermines how many yellow alarms must occur before a Yellow Alarm FF
key is lit. The FF key lights when the counter exceeds the specified number
within a 24-hour period.
For instructions on programming 
Tl alarm keys, see the TI Reference
Manual (Section 500).
Programming
FFl...

Page 465

Chapter 1. System Programming (FFl )Section 400-ProgrammingYellow Alarm Relay
Software Version: CPC-B Version 4.0 or higherAddress: Master Cabinet: 
FFl 8# 4## 4## 4# l# (0 or l)#
Slave Cabinet:FFl 8# 4# 5# 4# l# (0 or l)#DescriptionDetermines whether the system closes the alarm relay on the 
Tl MDF card in
the event of yellow alarms.
The alarm relay can be connected to an external alarm device such as a
buzzer. (This device must be purchased separately; it is not provided with the
DBS 
Tl.)
The Yellow...

Page 466

Section 400-ProgrammingChapter 1. System Programming (FFl)
Red Alarm Relay
Software Version:C&-B Version 4.0 or higher.Address: Master Cabinet: 
FFl 8## 4# 4# 4#/ 2# (0 or l)#
Slave Cabinet:FFl 8# 4#I 5## 4## 2# (0 or l)#
DescriptionDetermines whether the system closes the alarm relay on the Tl MDF card in
the event of red 
alan-ns. A red alarm indicates that a loss of frame (OOF) or
loss of signal has continued for more than 2.5 seconds.
The alarm relay can be connected to an external alarm device such...

Page 467

Chapter 1. System PrOgrammIng (Wl)Sectlon 400~ProgrammingSync 
Loss Relay
Software Version:CPC-B Version 4.0 or higherAddress: Master Cabinet: 
FFl 8# 4## 4## 4#I 3# (0 or l)#
Slave Cabinet:FFl 8W 4# 5# 4#I 3# (0 or l)#
DescriptionDetermines whether the system closes the alarm relay on the Tl MDF card in
the event of sync loss alarms, which result from clocking errors.
The alarm relay can be connected to an external alarm device such as a
buzzer.(This device must be purchased separately; it is not...

Page 468

Section 400-ProgrammingChapter 1. System Programming (FFI )
Frame Loss Relay
Software Version:CPC-6 Version 4.0 or higherAddress:. Master Cabinet: 
FFl 8# 4## 4# 4#! 4# (0 or l)#
Slave Cabinet:FFl 8# 4## 5# 4# 4## (0 or l)#
DescriptionDetermines whether the system closes the alarm relay on the Tl MDF card in
the event of frame loss alarms.
The alarm relay can be connected to an external alarm device such as a
buzzer. (This device must be purchased separately: it is not provided with the
DBS 
Tl.)...

Page 469

Chapter 1. System Programming (FFl)Section 400-Programming
AIS Relay
Software Version:CPC-B Version 4.0 or higherAddress: Master Cabinet: 
FFl 8# 4# 4# 4# 5# (0 or l)#
Slave Cabinet:FFl 8# 4# 5# 4# 5# (0 or I)#
DescriptionDetermines whether the system closes the alarm relay on the Tl MDF card in
the event of Alarm Indication Signals 
(AIS), which are comprised of all l’s
and are unframed.
The alarm relay can be connected to an external alarm device such as a
buzzer. (This device must be purchased...

Page 470

Section 400-Programming
Chapter 1. System Programming (FFI)
Relay Reset
Sofhwak Version:CPC-B Version 4.0 or higherAddress: Master Cabinet: 
FFl 8# 4# 4## 4# 6# (0 or I)#
Slave Cabinet:FFl 8# 4## 5## 4#/ 6# (0 or l)#
DescriptionDetermines whether the Tl alarm relay is cleared (opened) automatically or
manually.l
If cleared automatically, the relay is opened approximately one second
after the alarm condition ceases.
lIf cleared manually, the relay can be opened by entering the Alarm Relay
Clear code:...