Page 431
Disconnect Timer Software Version:CPC-B Version 4.0 or higherAddress: FFl 8# 4# 2# 2# (0112)# DescriptionDetermines how long the DBS waits before sending a disconnect signal from the Tl to the CO (200 ms by default). NOTE: The CO Disconnect Timer (FF2 Trunks 18# O-l%) determines how long the system waits to receive a disconnect signal from the CO. Programming FFl 8# 4# 2# 2# (0112)# ;I Disconnect Timer setting Default: 1 (200 ms) (see table below) Table l-37. TI Disconnect Timer values Setting 0 Value...
Page 432
Section 400-ProgrammingChapter 1. System Programming (FFi) Guard Timer Software Version:CPC-B Version 4.0 or higherAddress: FFl 8# 4# 2# 3# (0-15)# DescriptionDetermines how long the system guards a Tl circuit (1200 ms by default). When the DBS “guards” a circuit, it holds the circuit after it has been released to make sure the previous call is properly disconnected. This means the channel cannot be used for another call until the Guard Timer has expired. Programming I FFI 8# 4# 2# 3# (O-15)# Guard...
Page 433
Chapter 1. System Programming (FFl)Section 400-Programming Release Acknowledge Timer Software Version:CPC-6 Version 4.0 or higherAddress: FFl 8# 4## 2# 4# (0-15)# DescriptionDetermines how long the DBS waits for the CO to acknowledge a disconnect signal (240 seconds by default). Once this timer expires, the DBS will abandon the call even if the CO has not acknowledged the disconnect. This allows the DBS to disconnect idle Tl trunks if the CO is not signaling properly. Programming FFl 8# 4# 2# 4#...
Page 434
Section 4uo-rrogrammtngc;napter 1. system rrogrammlng (FFI) Outpulse Delay Timer Software Version:CPC-B Version 4.0 or higherAddress: FFl 8## 4# 2# 5# (0-S)## DescriptionDetermines how long the system waits before outpuising dialed digits to the network (500 ms by default). Programming FFl 8## 4# 2# 5# (018)# f Outpulse Delay Timer setting Default: 2 (500 ms) (see table below) Table l-40. Outpulse Delay Timer values DBS-70-400DBS Manual - Issued 8/l/95Page 1-149
Page 435
Chapter 1. System Programming (FFl)Section 400-Programming Wink Timeout Timer Software Version:CPC-B Version 4.0 or higherAddress: FFl 8# 4# 2# 6# (O-15)# DescriptionWhen wink-start signaling is used, the DBS waits for a wink signal from the CO when an extension user goes off-hook. Once a wink signal is received, the DBS sends CO dial tone to the extension. This timer determines how long the DBS waits for a wink signal once an extension user goes off-hook (5500 ms by default). If the DBS does not...
Page 436
Section 400-ProgrammingChapter 1. System Programming (FFl) Incoming Detection Timer Software Version:CPC-B Version 4.0 or higherAddress: FFl 8# 4## 2# 7# (0-15)# DescriptionOnce an incoming call seizes a DBS Tl trunk, this timer determines how long the DBS waits before recognizing the seizure as an incoming call (90 ms by default). The purpose of this timer is to prevent false incoming ringing. This parameter only applies when E&M signaling is used. Programming 1 1 FFl 8# 4# 2# 7# (0-15)# f Incoming...
Page 437
Chapter 1. System Programming (FFl)Section 400-Programming Answer Supervision Timer Sofhvare Version:CPC-B Version 4.0 or higherAddress: FFl 8# 4## 2# 8# (0-8)# DescriptionWhen the DBS generates a call over the Tl. answer supervision is provided to determine if the call is actually answered. This timer determines how long the offhook signal from the called party must last before the DBS treats the offhook signal as an answer. Programming I FFl 8# 4# 2# 8# (018)# f Answer Supervision Timer setting...
Page 438
Section 400-ProgrammingChapter 1. System Programming (FFl) Immediate Glare Timer Software Version: CPC-B Version 4.0 or higherAddress: FFl 8# 4## 2# 9# (0115)# Description Programming“Glare” occurs when both ends of the same trunk are seized simultaneously, resulting in connection between an incoming call and a DBS phone user attempting to access an outside line. Use this address to prevent glare when immediate-start signaling is used. This timer determines how long the DBS will search for an incoming...
Page 439
Chapter I. System Programming (FF’l)Section 400-Programming Wink Glare Timer Software Version:CPC-B Version 4.0 or higherAddress: FFl 8# 4# 2# 10# (0-15)# Description“Glare” occurs when both ends of the same trunk are seized simultaneously, resulting in connection between an incoming call and a DBS phone user attempting to access an outside line. Use this address to prevent glare from occurring when wink-start signaling is used. This timer determines how long the DBS will search for an incoming call on...
Page 440
Section 400~ProgrammingChapter 1. System Programming (FFl) Digital Pad Settings Software Version: CPC-Bversion 4.0 or higherAddress: FFl 8# 4## 3# (l-12)# (l-12)# (0-30)# DescriptionAdjusts the volurne of connections made via the Tl. Default volume levels are included for connections between different types of terminals or circuits. For example, a KTel-to-T1 connection may use one volume setting, while an SLT-to-T1 connection may use another. The volume settings are controlled by changing a pad number,...