Home > Panasonic > Communications System > Panasonic Cpc+AII/B Digital Business System Release Notes Manual

Panasonic Cpc+AII/B Digital Business System Release Notes Manual

Here you can view all the pages of manual Panasonic Cpc+AII/B Digital Business System Release Notes Manual. The Panasonic manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 431

Disconnect Timer
Software Version:CPC-B Version 4.0 or higherAddress: 
FFl 8# 4# 2# 2# (0112)#
DescriptionDetermines how long the DBS waits before sending a disconnect signal from
the Tl to the CO (200 ms by default).
NOTE: The CO Disconnect Timer (FF2 Trunks 18# O-l%) determines how
long the system waits to 
receive a disconnect signal from the CO.
Programming
FFl 8# 4# 2# 2# (0112)#
;I
Disconnect Timer setting
Default: 1 (200 ms) (see table below)
Table l-37. TI Disconnect Timer values
Setting
0
Value...

Page 432

Section 400-ProgrammingChapter 1. System Programming (FFi)
Guard Timer
Software Version:CPC-B Version 4.0 or higherAddress: 
FFl 8# 4# 2# 3# (0-15)#
DescriptionDetermines how long the system guards a Tl circuit (1200 ms by default).
When the DBS “guards” a circuit, it holds the circuit after it has been released
to make sure the previous call is properly disconnected. This means the
channel cannot be used for another call until the Guard Timer has expired.
Programming
I
FFI 8# 4# 2# 3# (O-15)#
Guard...

Page 433

Chapter 1. System Programming (FFl)Section 400-Programming
Release Acknowledge Timer
Software Version:CPC-6 Version 4.0 or higherAddress: 
FFl 8# 4## 2# 4# (0-15)#
DescriptionDetermines how long the DBS waits for the CO to acknowledge a disconnect
signal (240 seconds by default).
Once this timer expires, the DBS will abandon the call even if the CO has not
acknowledged the disconnect. This allows the DBS to disconnect idle 
Tl
trunks if the CO is not signaling properly.
Programming
FFl 8# 4# 2# 4#...

Page 434

Section 4uo-rrogrammtngc;napter 1. system rrogrammlng (FFI)
Outpulse Delay Timer
Software Version:CPC-B Version 4.0 or higherAddress: 
FFl 8## 4# 2# 5# (0-S)##
DescriptionDetermines how long the system waits before outpuising dialed digits to the
network (500 ms by default).
Programming
FFl 8## 4# 2# 5# (018)#
f
Outpulse Delay Timer setting
Default: 2 (500 ms) (see table below)
Table l-40. Outpulse Delay Timer values
DBS-70-400DBS Manual - Issued 8/l/95Page 1-149 

Page 435

Chapter 1. System Programming (FFl)Section 400-Programming
Wink Timeout Timer
Software Version:CPC-B Version 4.0 or higherAddress: 
FFl 8# 4# 2# 6# (O-15)#
DescriptionWhen wink-start signaling is used, the DBS waits for a wink signal from the
CO when an extension user goes off-hook. Once a wink signal is received,
the DBS sends CO dial tone to the extension.
This timer determines how long the DBS waits for a wink signal once an
extension user goes off-hook (5500 ms by default). If the DBS does not...

Page 436

Section 400-ProgrammingChapter 1. System Programming (FFl)
Incoming Detection Timer
Software Version:CPC-B Version 4.0 or higherAddress: 
FFl 8# 4## 2# 7# (0-15)#
DescriptionOnce an incoming call seizes a DBS Tl trunk, this timer determines how long
the DBS waits before recognizing the seizure as an incoming call (90 ms by
default). The purpose of this timer is to prevent false incoming ringing.
This parameter only applies when E&M signaling is used.
Programming
1
1
FFl 8# 4# 2# 7# (0-15)#
f
Incoming...

Page 437

Chapter 1. System Programming (FFl)Section 400-Programming
Answer Supervision Timer
Sofhvare Version:CPC-B Version 4.0 or higherAddress: 
FFl 8# 4## 2# 8# (0-8)#
DescriptionWhen the DBS generates a call over the Tl. answer supervision is provided to
determine if the call is actually answered. This timer determines how long
the 
offhook signal from the called party must last before the DBS treats the
offhook signal as an answer.
Programming
I
FFl 8# 4# 2# 8# (018)#
f
Answer Supervision Timer setting...

Page 438

Section 400-ProgrammingChapter 1. System Programming (FFl)
Immediate Glare Timer
Software Version:
CPC-B Version 4.0 or higherAddress: 
FFl 8# 4## 2# 9# (0115)#
Description
Programming“Glare” occurs when both ends of the same trunk are seized simultaneously,
resulting in connection between an incoming call and a DBS phone user
attempting to access an outside line.
Use this address to prevent glare when immediate-start signaling is used.
This timer determines how long the DBS will search for an incoming...

Page 439

Chapter I. System Programming (FF’l)Section 400-Programming
Wink Glare Timer
Software Version:CPC-B Version 4.0 or higherAddress: 
FFl 8# 4# 2# 10# (0-15)#
Description“Glare” occurs when both ends of the same trunk are seized simultaneously,
resulting in connection between an incoming call and a DBS phone user
attempting to access an outside line.
Use this address to prevent glare from occurring when wink-start signaling is
used. This timer determines how long the DBS will search for an incoming
call on...

Page 440

Section 400~ProgrammingChapter 1. System Programming (FFl)
Digital Pad Settings
Software Version: CPC-Bversion 4.0 or higherAddress: 
FFl 8# 4## 3# (l-12)# (l-12)# (0-30)#
DescriptionAdjusts the volurne of connections made via the Tl. Default volume levels
are included for connections between different types of terminals or circuits.
For example, a 
KTel-to-T1 connection may use one volume setting, while an
SLT-to-T1 connection may use another.
The volume settings are controlled by changing a pad number,...