Home
>
Panasonic
>
Communications System
>
Panasonic Cpc+AII/B Digital Business System Release Notes Manual
Panasonic Cpc+AII/B Digital Business System Release Notes Manual
Here you can view all the pages of manual Panasonic Cpc+AII/B Digital Business System Release Notes Manual. The Panasonic manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 421
Chapter 1. System Programming (FFI)Section 400-Programming Table l-36. Minimum Tl programming (default settings appear in bold) STEP 1 -- NEW FUNCTION RESET Address: Description: Options: , FFl 8# l# (0 or l)# (to select the reset) FFl 8# 2# (0 or l)# (to complete the reset) Must be performed if you are installing Tl while upgrading to a new CPC-B release (e.g., from 6.2 to 7.0). Not needed if you are upgrading to a “point” release (e.g., from 6.0 to 6.2). O=Do not reset l=Reset STEP 2 -- SYSTEM...
Page 422
Section 400-ProgrammingChapter 1. System Programming (FFl) iddress: continued) Iescrip tion: continued) lp tions: Zxamples: FFl 8# 4# l# 2# (l-3)# for Sync Source 1 FFl 8# 4# I# 3# (0-3)# for Sync Source 2 FFl 8# 4# l# 4# (0-3)# for Sync Source 3 The “Free run” setting is the only setting that can be entered for more than one sync source. One of the three sync sources should be set to “Free run”, so that the Tl can provide its own clocking if the network clock fails. For changes to this parameter to...
Page 423
Chapter 1. System Programming (FFl ) Section 400-Programming STEP 5 -- NUMBER OF Tl CHANNELS Address: Description: Options: FFl 8# # 4# l# 2# (0-24)# for Master Cabinet FFl 8# 4# 5# l# 2# (0-24)# for Slave Cabinet Specify the number of Tl channels used when “Fractional Tl” is needed (using only a portion of the 24 available channels on the Tl card). 0 = None (no Tl channels are used) 1 thru 24 = Number of Tl channels used STEP 6 -- FRAME FORMAT iddress: Jescription: Options: FFl 8# # 4# l# 3# (0 or l>#...
Page 424
STEP 8 -- TRUNK CIRCUIT TYPE Iddress: >escription: 1p tions: Section 400-ProgrammingChapter 1. System Programming (FFCFF2 (l-64)# 21# (0-4)## Specify which trunk channels are used for Tl. When assigning trunks as circuit type “3” (Tl), start from the highest-numbered trunk port in the DBS cabinet struc- ture, and move down sequentially from there. If Fractional Tl is used, make sure that the number of trunks assigned to circuit type “3” (Tl) matches the “Num ber of Tl Channels” setting (see STEP 5...
Page 425
Chapter 1. System Programming (FFi)Section 400-Programming STEP 10 -- OUTGOUNG SIGNALING TYPE Address: Description: Options: FFl 8# # 6# (l-64)# 3# (0-2)# Specify the outgoing signaling type used by the Tl. Be sure to match the signaling ordered from the CO. For changes to this parameter to take effect, the system must be powered down, then powered back up. 0 = Immediate Start l=WinkStart 2 = Dial Tone Start STEP 11 -- INCOMING SIGNALING TYPE 4ddress: Description: 3ptions: FFl 8# 4#/ 6# (l-64)# 4# (0 or...
Page 426
Section 400-ProgrammingChapter 1. System Programming (FFl) SyncSource1 Software Version:CPC-6 Version 4.0 or higherAddress: FFl 8## 4# 1# 2# (l-3)## DescriptionThe Sync Card (installed on the CPC-B) provides a method of synchronizing the DBS with the public network. This address determines the first clocking source for network synchronization (internal clocking by default). If the first clocking source fails, the system wili switch to the second source. The system will attempt to go back to the fist...
Page 427
Chapter 1. System Programming (FFl)Section 400-Programming Restriction on Duplicate Sync Settings. “Free run” is the only setting that can be entered for more than one sync source.Power-Cycling Requirement. For changes to this parameter to take effect, the system must be turned off, then back on.Page l-142DBS Manual - Issued 8/l/95DBS-70-400
Page 428
Section 400-ProgrammingChapter 1. System Programming (FFl) Sync Source 2Software Version: WC-6 Version 4.0 or higher Address: FFl 8# 4# l# 3# (O-3)# DescriptionDetermines the source of clocking for the second sync source, which is used if the first sync source fails. If the second sync source is used, the DBS system will attempt to switch back to the first source based on the value set for the Network Re-Sync Timer (see FFl 8# 4# 2# l# 0-25#). If the second source fails and the first source is not...
Page 429
waprer I. sysrem rrogrammlng (t-r I 13ecIion 4uu-rrogrammwig Sync Source 3 Software Version:CPC-B Version 4.0 or higherAddress: FFI 8# 4# 1# 4# (0-3)# DescriptionDeterrnines the source of clocking for the third sync source, which is used if both the first and second sources fail. If the third sync source is used, the DBS system will attempt to switch back to the first source based on the value set for the Network Re-Sync Timer (see FFl 8# # 2# l# O-2%). In most cases, a system with one Tl has the third...
Page 430
Section 400-ProgrammingChapter 1. System Programming (FFI) Network Re-Sync Timer Sofhwate Version: CPC-B Version 4.0 or higherAddress: FFl 8# M 2# 1# (O-25)# DescriptionIf one clock source fails, the system will switch to another clock source. The Network Re-Sync Timer determines how many times (once an hour) the system attempts to return to the original clock source. For example, if the first clocking (sync) source fails, the system will switch to the second source, and then will attempt to return to...