SLT Onhook Flash Timer
Software Version: All VersionsAddress: 
Ffl 3# 14## (0-6)#
DescriptionThis timer determines how long an SLT user must hold down the switchhook
before the DBS recognizes a hookflash (200 ms by default). This address
also includes a setting that prevents hookflashes from being performed on
SLTs.
If you change ,this setting, you must turn the system off, then back on to
activate the change.
Programming
I
FFl 3# 14# (0-6)#
t
SLT Onhook Flash Timer setting
Default: 4 
(valid flash=200...

Page 392

Section 400-Programming
Chapter 1. System Programming (FFl j
CO Ring Cycle Detection TimerSoftware Version: All Versions
Address: 
FFl 3# 15# (0-3)#
DescriptionThis timer determines how long the DBS attempts to detect an incoming CO
ring cycle (6 seconds by default).
To ensure that the DBS can recognize incoming trunk calls, set this timer to
equal the duration of the ring cycle --
including 
the first “on” period and the
first “off’ period. For example, if the ring cycle for an incoming trunk is 2...

Page 393

Chapter 1. system rrogrammlng (t-k1 )section 400~Programming
Inbound Ring Cycle Expansion Timer
Software Version: All VersionsAddress: 
FFl 3## 16# (0-15)#
DescriptionIf the incoming ring pattern for an extension (FF3 ExtPort# 39#) is set to
emulate CO ringing, an extension may sometimes receive a very short ring
burst when a trunk call begins ringing. This short ring burst occurs because
the DBS received only part of the first “on” burst (see Figure l-2, previous
page) from the trunk.
To eliminate these...

Page 394

Section 400-ProgrammingChapter 1. System Programming (FFl)
Dial Pause Timer
Software Version: All VersionsAddress: 
FFl 3# 17# (O-15)#
DescriptionUse this address to insert a pause (1.5 seconds by default) before outpulsing
dialed digits, once a CO trunk is accessed.
The pause is used in speed-dialing (SSD and PSD) and in Least Cost Routing
uw.
Programming
I
FFl 3#I 17# (045)#
Dial Pause Timer setting
Default: 1 (1.5 seconds) (see table below)
Tdle I-22. Dial Pause Timer values
SettingValue
1 1.2...

Page 395

Chapter 1. System Programming (FFl)Section 400-Programming
PBX Flash TimerSoftware Version: All Versions
Address: 
FFl 3#I 18# (0-lO)#
DescriptionWhen a DBS trunk is defined as a PBX trunk, the FLASH key can be used to
place a call on hold.
This timer determines how long the flash signal will last if the FLASH key is
pressed then immediately released 
(.8 seconds by default).
If the FLASH key is pressed and held down, the flash signal will last as long
as the key is pressed.
Programming
I
FFl 3# 18#...

Page 396

Section 400-ProgrammingChapter 1. System Programming (FFl)Call Forward-No Answer Timer
Software Version: All VersionsAddress: 
FFl 3# 19# (O-15)#
DescriptionThe Call Forward-No Answer Timer determines how long an unanswered call
will ring at an extension before it is sent to a secondary destination (12
seconds by default).
NOTE: Although this address is present in all CPC versions, it controls
different ringing features in different versions (see table below):
Table I-24.King control for Call Forward-No...

Page 397

Chapter 1. System Programming (FFl)Section 400-Programming
Outbound Ground Start Detection TimerSoftware Version: 
@PC-B Version 1.0 or higher
Address: 
FFl 3## 20# (1-8)#
DescriptionThis timer determines how long the DBS waits for the CO to ground the Tip
side of a trunk (4 seconds by default). before establishing a connection
between the extension and the CO.
When an extension attempts to place an outgoing call on a ground-start trunk,
the DBS grounds the Ring side of the trunk. 
in response, the CO...

Page 398

Section 400-ProgrammingChapter 1. System Programming (FFl)
Inbound Ground Start Detection Timer
Software Version:CPC-B Version 1 .O or higherAddress: 
FFl 3## 21# (l-8)#
DescriptionThis timer determines how long a CO Tip ground signal must be present
before the DBS recognizes it as a valid incoming call (4 seconds by default).
When the CO sends a call to a ground-start DBS trunk, it signals the incoming
call by grounding the Tip side of the trunk.
In most cases, this timer should be set to 3 seconds or...

Page 399

Chapter 1. System Programming (FFl)Section 400-Programming
Attendant Hold Recall Timer for Intercom Calls
Software Version:CPC-Ail (all versions) and CPC-B Version 2.0 or higherAddress: 
FFl 3## 22# (0-12)#
DescriptionThis timer determines how long an intercom call will remain on hold at an
Attendant phone before it recalls (20 seconds by default).
Programming
II
FFl 3# 22# (0;12)#
Attendant Hold Recall Timer setting for Intercom Calls
Default: 1 (20 seconds) (see table below)I
Table l-28. Attendant Hold...

Page 400

Section 400-ProgrammingChapter 1 System Programming (FFl)Extension Hold Recall Timer for Intercom Calls
Software Version:CPC-All (ail versions) and CPC-B Version 2.0 or higherAddress: 
FFl 3# 23# (0-12)#
DescriptionThis timer determines how long an intercom call will remain on hold at an
extension phone before it recalls (140 seconds by default).
Programming
FFl 3# 23# (0-12)#
f
Extension Hold Recall Timer setting for intercom calls
Default: 7 (140 seconds) (see table below)
Table l-29. Extension Hold...