Page 501

Seotion 400~ProgrammingChapter 2. Trunk Programming (FF2)
Trunk Disconnect Detection Timer
Software Version: All VersionsAddress: FF2 (Trunk)# 
18# (O-15)#
DescriptionWhen the trunk side of a CO call disconnects, the CO sends the DBS a
disconnect signal by opening the loop (cutting voltage) for a specified length
of time.
This timer determines how long the DBS expects the disconnect signal to last.
By default, an open loop of 350 ms or more will be interpreted as a disconnect
signal.
The standard range...

Page 502

Chapter 2. Trunk Programming (FF2)’Section 400-Programming
DISA Start Time
Software Version: All Versions
Address: FF2 (Trunk)# 19# (HHMM)#
DescriptionUse this address to program a DISA trunk to begin DISA operation at a
specified time each day. Trunks are 
enabled for DISA using the DISA Auto
Answer address (FF2 
Trunk# 1 l#). Use this DISA Start ‘lime address, and
the DISA End Time address following, to limit DISA operation on a trunk to
a certain time period each day.
Programming
To set the DISA Start...

Page 503

Section 400-ProgrammingChapter 2. Trunk Programming (FF2)
DISA End Time
Software Version: All VersionsAddress: FF2 (Trunk)# 
20# (HHMM)#
DescriptionUse this address to program a DISA trunk to stop DISA operation at a
specified time each day. Trunks are enabled for 
DISA using the DISA Auto
Answer address (FF2 
Trunks 1 l#). Use this DISA End Tiie address, and the
DISA Start Time address (previous page), to limit DISA operation on a trunk
to a certain time period each day.
.
NOTE: The DBS will disable...

Page 504

Trunk Circuit Type
Software Version:CPC-Ail and CPC-B (all versions)Address: FF2 (Trunk)# 
21# (Type)#
DescriptionThis program determines the type of circuit for each trunk (Loop Start by
default).
NOTE:The circuit types available in each system depend on the CPC card
version. See 
“Notes” below for more information.
ProgrammingFF2 
(1164)# 21# (0-4)#
++
Trunk NumberO=Loop Start
l=Ground Start
2=Analog DID
3=Tl
4=Caller ID (loop start)
Related ProgrammingCall Duration Timer (for Caller ID): 
FFl 2# l#...

Page 505

Section 400~ProgrammingChapter 2. Trunk Programming (FF2)
Ground Start Circuit Type Considerations:
1. Not available with CPC-AIL
2. Ground Start lines perform similarly to Loop Start: however, in terms
of positive disconnect signals, Ground Start lines provide the most
reliable connection between the CO and the DBS, with the least
possibility of call collision or “glare”.
3. The Ground Start Trunk Card (VB-4353 1) is required for ground-start
operation.
4. The Ground Start Trunk Card requires a -48 volt...

Page 506

5. If Fractional Tl (using only a portion of the 24 available Tl channels)
is implemented, make sure that the number of trunks set to Circuit
Type 
“Tl” matches the programmed Number of Tl Channels (FFl
8# # 4/5# l# 2# O-24+0.
6. In CPC-B Versions 5.0 to 6.02, if trunk usage on an analog trunk card
is divided between 
Tl and analog, make sure that the Tl trunks are
closed from analog usage in the 
Tl Trunk Closure address (FFl8# 7#
l-2# l-# l-8# 0-l#).
Caller ID Circuit Type Considerations:
1. Available...

Page 507

--
.- -
DID Immediate or Wink Start
Software Version:CPC-B Version 2.0 or higherAddress: FF2 (Trunk)# 
22# (0 or l)#
DescriptionThis address determines the type of signaling used with DID trunks (Wink
Start by default).
If “Wink Start” is selected, the 
CO seizes the DID trunk. Then the DBS sends
a wink signal to the CO. At the end of the wink signal, the 
CO transmits the
DID digits.
If “Immediate” is selected, the CO seizes the DID trunk. Then the DBS waits
65 milliseconds before accepting the digits...

Page 508

-..-r.-. C. I,“,,... “J..d’,,,,, “‘J,. - ‘fW”V..V.. .“” , I” I-.....,.,,
Wink Start Timer
Software Version:CPC-6 Version 2.0 or higherAddress: FF2 (Trunk)# 
23# (0-15)#Description
This timer determines the duration of the “wink” that is sent to the CO
following the CO’s seizure of a DID trunk 
(200 ms by default).
At the conclusion of the wink, the CO transmits the DID digits to the DBS.
Programming
FF2 (1164)# 23# (O-1 5)#
tA
Trunk Number
Wink Start Timer settingDefault: 3 
(200 ms)
(see table below)...

Page 509

Section 400~ProgrammingChapter 2. Trunk Programming (FF2)
Time Out for Dialed DID Digits
Software Version:CPC-B Version 2.0 or higherAddress: FF2 (Trunk)# 
24## (O-15)#
DescriptionThis timer determines how long the DBS waits for DID digits, once CO
signaling has indicated that digits are to be transmitted (18 seconds by
default).
ProgrammingFF2 
(1164)# 24#! (0115)#
f+
Trunk NumberTimeout setting for Dialed DID Digits
Default: 4 (18 seconds)
(see table below)
Table 2-4.DID Dialed Digit Timer values...

Page 510

Chapter 2. Trunk Programming (FF2)Section 400-ProgrammingDID Interdigit Timeout
Sofbvare Version:CPC-B Version 2.0 or higherAddress: FF2 (Trunk)# 
25# (O-15)#
DescriptionOnce the CO begins to outpulse DID digits, this timer determines how much
time is allowed between each digit (80 ms by default). If the timer is
exceeded, the DBS returns the DID trunk to the idle state.
Programming
FF2 (1164)# 25# (O-l 5)#
f+
Trunk Number
DID Interdigit Timer setting
Default: 5 (80 ms)
(see table below)
Table 2-5.DID...