Maintenance191 6Press the softkey for Reinserted or New. Select Reinserted if you refit the printhead that you just removed. Select New if you replaced the original printhead. The screen displays this message for every printhead you replaced. Note:To achieve optimal print quality, the system must know if the inserted printhead is warm or cold. A reinserted printhead will be warm while a new printhead will be cold. Always store your printheads at room temperature. 7The screen displays the message Make sure that all head covers are properly positioned. Press the key for Done. The screen displays the message Close top cover. 8Close the top cover. The screen displays the message Carriage moving to home position... 9Press the softkey for Next to start the calibration and the alignment of the printheads. The screen displays Calibrating.... The calibration process takes several minutes. You can stop the calibration process at any time. Press the key for Cancel to stop the calibration process. When the calibration is completed, the screen displays the calibration status. Downloaded From ManualsPrinter.com Manuals
192 Océ TCS400 User manual Replace the maintenance cassette Introduction The maintenance cassette wipes the printheads and caps the printhead nozzles. When to do Replace the maintenance cassette in the following situations: ■The printer operator panel displays the message Maintenance cassette nearly full. The print quality can deteriorate. Replace the cassette as soon as possible. ■The printer operator panel displays the message Maintenance cassette full. Press Continue to start the Replace cassette wizard. The Océ System Control Panel also indicates that you must replace the cassette. The message Maintenance cassette full. Press Continue to start the Replace cassette wizard appears. When the maintenance cassette is full, the system produces a double audio signal. The red LEDs of the printer operator panel remain illuminated. Immediate action is required. The printer operator panel displays this message after about 5000 m 2 of output. The exact value depends on the print modes you use. The message gives access to a wizard that contains the procedure to replace the maintenance cassette. When the maintenance cassette is not in position when the system starts up, the system produces an error signal The red LEDs of the printer operator panel remain illuminated. The printer operator panel displays the message Maintenance cassette not present. The message gives access to a wizard that contains the procedure to replace the maintenance cassette. You can always access the wizard in the off-line mode. Downloaded From ManualsPrinter.com Manuals
Maintenance193 How to remove the maintenance cassette Attention: Do not remove the maintenance cassette if you are not in the wizard. You can seriously damage the printheads. If you open the maintenance door outside the wizard, an error message prompts you to close the door. 1Press the on-line / off-line key on the printer operator panel to take the printer off-line. If you replace the cassette as the result of the message Maintenance cassette full. Press Continue to enter the Replace cassette wizard., press the softkey for Continue to enter the Replace cassette. wizard. Then continue with step 4. 2Use the upper softkeys to scroll to the Replace cassette card. 3Press the softkey below the Replace cassette card to enter the wizard. An introduction screen displays the message Use this wizard to replace the maintenance cassette. Downloaded From ManualsPrinter.com Manuals
194 Océ TCS400 User manual 4Use the upper right softkey to enter the wizard at the introduction screen. The screen displays the message Carriage moving to center position... while the carriage moves to the center. Then, the screen displays the message Open maintenance door. 5Open the door to the maintenance cassette. The screen displays the message Remove cassette. 6Press the green grip to the left to release the cover that gives access to the maintenance cassette. Downloaded From ManualsPrinter.com Manuals
Maintenance195 7Pull out the maintenance cassette. Note:Always store the old maintenance cassette in a horizontal position to prevent the spilling of ink. Be careful with the ink on the maintenance cassette. How to place the maintenance cassette 1 Slide the new maintenance cassette into the cassette holder. 2Close the cover of the maintenance cassette . The cover locks automatically. The screen displays the message Is the cassette you placed used or new? Downloaded From ManualsPrinter.com Manuals
196 Océ TCS400 User manual 3Press the key for Used or New. Select Used if you inserted a cassette that was used before. The end-of-life counter is not reset to zero. Select New if you inserted a cassette that was not used before. The end-of-life counter is reset to zero. Note:Make sure you select the correct option. Never select New for a used cassette. This can cause serious damage your printer. 4Close the door to the maintenance cassette. The screen displays the message Carriage moving to home position... Downloaded From ManualsPrinter.com Manuals
Maintenance197 Maintenance activities for the scanner Clean the scan area Introduction This section describes how to clean the glass plate and the white platen of your Océ TCS400 scanner. You can find the required tools in the maintenance kit supplied with the scanner. Required tools Two lint-free cloths. Streak-free, glass cleaner. Downloaded From ManualsPrinter.com Manuals
198 Océ TCS400 User manual How to clean the scan area Attention: Do not use abrasives, acetone, benzene or fluids that contain these chemicals: Do not spray liquids directly on the scanner. 1Turn off the scanner and disconnect the power plug. 2Open the scanner cover to expose the pressure platen. 3Remove the pressure platen. Use one hand to press down on the platen. Put two fingers in the openings on the front of the slider. Move the slider toward the center until the pressure platen disengages. [60 ] Use one ha nd to p res s down on the pl aten. Put t wo fin gers i n the o peni ngs on the fro nt of the sl ide r. M ove the s li der toward th e ce nter unti l the press ure pl aten d is engage s [60] Use one hand to press down on the platen. Put two fingers in the openings on the front of the slider. Move the slider toward the center until the pressure platen disengages Downloaded From ManualsPrinter.com Manuals
Maintenance199 Repeat the procedure for the other slider. Use the two handles on top of the pressure platen to remove the pressure platen. [61 ] On e of the two han dles on t op of th e press ure pl aten [61] One of the two handles on top of the pressure platen Downloaded From ManualsPrinter.com Manuals
200 Océ TCS400 User manual 4Clean the glass plate. Clean the glass plate with a lint-free cloth and a mild, streak-free, glass cleaner. Use a separate clean, dry lint-free cloth to dry the glass plate completely. 5Clean the white platen. The white background platen is on the back of the pressure platen you removed in step 3. Clean the white surface and the transport rollers with a lint-free cloth and a mild, streak-free, glass cleaner. First clean the platens white area and then the transport rollers. Use a separate clean, dry lint-free cloth to thoroughly dry the platen and the rollers. 6Replace the pressure platen. Use the two handles on top of the pressure platen to replace the pressure platen upright on the glass plate. Make sure the springs are fit over the pins. [62 ] Mak e s ure the s pring s are fi t ov er the pi ns [62] Make sure the springs are fit over the pins Downloaded From ManualsPrinter.com Manuals