    							NDA-24288 CHAPTER 4
    Page 69
    Revision 1.0
    AHSY
    179
    b0
    Not usedb1
    b2
    b3
    b4Designation of Guest Access Code
    b7b6b5b4ACC - CODEb7b6b5b4ACC - CODE
    0000 Out of Service 0111 7
    0001 1 1000 8
    0010 2 1001 9
    0011 3 1010 0
    0100 4 1011 *
    0101 5 1100 #
    0110 6
    b5
    b6
    b7
    180 00Not used
    181 00
    Not used
    1820
    b0Not used
    b1
    Called # printout (Alert Service)                                    
    0/1 = No/Yes
    b2
    When a guest station has been called out by Alert Service, if that guest station 
    is Busy, Locked Out, or under Make-Busy status, that information is printed 
    out.
    0/1 = Not Required/Required
    9
    b3
    STA # Answers = Printout                                             
    0/1 = No/Yes
    b4
    When a guest station has been called out by Alert Service, if that guest station 
    does not answer, the information is printed out.
    0/1 = Not Required/Required
    0
    b5
    Not used 0b6
    0b7
    INDEX
    (0 – 1023)DATA
    (DATA)
    00 – FF
    (Hex)BIT
    CORRESPONDING
    DATA
    CONTENTS
    DATA
    0/1BIT 
    						
    							CHAPTER 4 NDA-24288
    Page 70
    Revision 1.0
    AHSY
    183
    b0Setting of Attendant Console that sets Alert Service
    0 Hex: Service can be set from any of the Attendant Consoles
    1 - F Hex: Service can be set only from the Attendant Console of the 
    designated Console Number 
    b1
    b2
    b3
    b4
    Classifying the call termination indicating keys based on the Language 
    category of the guest at the time an incoming call from the guest station 
    terminated to the Attendant Console.
    0/1 = Not Required/Required
    b5Not used
    b6
    In the case of “All Event No Printout,”  the Hotel printer prints out only the 
    information pertaining to outgoing calls.
    0/1 = Out/In Service (The outgoing call data is assigned by INDEXes 360 
    through 367.)
    0
    b7Not used
    1840
    b0
    Not used 0
    b1
    0b2
    0b3
    0b4
    0b5
    b6Processing for “No Answer” at the Attendant Console in the case where 
    Automatic Wake-Up Attendant - Assistance service is provided.
    b7b6
    0 0 : Changeover to Automatic Wake-Up
    0 1 : No processing  for “No Answer”
    1 0 : Call termination to Attendant Console is canceled.
    1 1 : All Wake-Up calls are terminated to the Attendant Console 
    (including Automatic Wake-Up Call).
    b7
    INDEX
    (0 – 1023)DATA
    (DATA)
    00 – FF
    (Hex)BIT
    CORRESPONDING
    DATA
    CONTENTS
    DATA
    0/1BIT 
    						
    							NDA-24288 CHAPTER 4
    Page 71
    Revision 1.0
    AHSY
    1850
    b0Not used
    b1
    Guest Room Calling - Attendant Console Service
    0/1 = Out/In Service
    0
    b2
    Not used 0
    b3
    0b4
    0b5
    0b6
    0b7
    186
    b0
    Not used
    b1
    b2
    b3
    b4
    b5
    b6
    b7
    Double Suite Room Service
    0/1 = Out/In Service
    1870
    b0Not used
    0b1
    b2
    Processing for the case where there is any busy station among the Suite Room 
    stations generally called by Suite Room Calling - Attendant Console service
    0/1 = Sending Busy Tone/Idle Station Calling
    0
    b3
    Not used 0
    b4
    0b5
    0b6
    0b7
    INDEX
    (0 – 1023)DATA
    (DATA)
    00 – FF
    (Hex)BIT
    CORRESPONDING
    DATA
    CONTENTS
    DATA
    0/1BIT 
    						
    							CHAPTER 4 NDA-24288
    Page 72
    Revision 1.0
    AHSY
    188
    b0Processing for Suite Room Station/Connecting Room Station Busy
    b1b0
    00: Busy Tone
    0 1 : An idle station within the room is called
    1 0 : From a station, the call is transferred to the Attendant Console if the 
    caller is not the console operator.
    b1
    0b2Fixed Data
    0b3
    0b4Not used
    b5
    When a call terminates to the Double Suite Room:
    0/1 = All stations ring simultaneously/Alternately between Primary Suite and 
    Secondary Suite
    1
    b6Fixed Data
    b7
    Suite Room Service
    0/1 = Out/In Service
    189
    b0
    Not used
    b1
    b2
    b3
    b4
    b5
    Calling an Individual Suite Room Station Calling
    0: An individual Suite Room station can be called from a Guest Station, 
    Administration Station, and Attendant Console.
    1: An individual Suite Room station can be called from a Special 
    Administration and Attendant Console.
    b6
    Ringing at the time of general calling in the Connecting Room or Suite Room 
    stations.
    0: Ringing all stations.
    1: Ringing the station in the main room for the Connecting Room; ringing the 
    Primary station for a Suite Room
    b7
    Number to be dialed for general calling of the station in the Suite Room
    0: Primary Station Number or Pilot (Phantom) Number
    1: Only Pilot (Phantom) Number
    190 00
    Not used
    INDEX
    (0 – 1023)DATA
    (DATA)
    00 – FF
    (Hex)BIT
    CORRESPONDING
    DATA
    CONTENTS
    DATA
    0/1BIT 
    						
    							NDA-24288 CHAPTER 4
    Page 73
    Revision 1.0
    AHSY
    191 00
    Not used
    192 00
    Not used
    193 00
    Not used
    194 00
    Not used
    195 00
    Not used
    196 00
    Not used
    197 00
    Not used
    198 00
    Not used
    199 00
    Not used
    200 00
    Not used
    201 00
    Not used
    202 00
    Not used
    203 00
    Not used
    204 00
    Not used
    205 00
    Not used
    206 00
    Not used
    207 00
    Not used
    208 00
    Not used
    209 00
    Not used
    210 00
    Not used
    211 00
    Not used
    212 00
    Not used
    213 00
    Not used
    214 00
    Not used
    215 00
    Not used
    216 00
    Not used
    217 00
    Not used
    218 00
    Not used
    219 00
    Not used
    220 00
    Not used
    221 00
    Not used
    222 00
    Not used
    223 00
    Not used
    224 00
    Not used
    225 00
    Not used
    INDEX
    (0 – 1023)DATA
    (DATA)
    00 – FF
    (Hex)BIT
    CORRESPONDING
    DATA
    CONTENTS
    DATA
    0/1BIT 
    						
    							CHAPTER 4 NDA-24288
    Page 74
    Revision 1.0
    AHSY
    226 00
    Not used
    227 00
    Not used
    228 00
    Not used
    229 00
    Not used
    230 00
    Not used
    231 00
    Not used
    232 00
    Not used
    233 00
    Not used
    234 00
    Not used
    235 00
    Not used
    236 00
    Not used
    237 00
    Not used
    238 00
    Not used
    239 00
    Not used
    240 00
    Not used
    241 00
    Not used
    242 00
    Not used
    243 00
    Not used
    244 00
    Not used
    245 00
    Not used
    246 00
    Not used
    247 00
    Not used
    248 00
    Not used
    249 00
    Not used
    250 00
    Not used
    251 00
    Not used
    252
    b0
    Room Key Information
    0/1 = Key Rack Type/Card Rack Type
    0
    b1~b7Not used
    253 00 Not used
    254 00 Not used
    255 00 Not used
    256 00 Not used
    257 00 Not used
    INDEX
    (0 – 1023)DATA
    (DATA)
    00 – FF
    (Hex)BIT
    CORRESPONDING
    DATA
    CONTENTS
    DATA
    0/1BIT 
    						
    							NDA-24288 CHAPTER 4
    Page 75
    Revision 1.0
    AHSY
    2580
    b0Not used
    b1
    Maid Status - Cleaning Start via Guest Station
    (Feature Code = 11, Function Code = 1)
    Sending Service Feature 
    Text (Information) to PMS
    0/1 = In Service/Out 
    Service
    When the text is not to be 
    sent to PMS, “1” is assigned 
    to the corresponding bit.
    b2
    Maid Status - Cleaning End via Guest Station
    (Feature Code = 11, Function Code = 2)
    b3
    Maid Status - Inspection End via Guest Station
    (Feature Code = 11, Function Code = 3)
    0
    b4
    Not used 0b5
    0b6
    0b7
    259Not used
    260
    b0Not used
    b1
    Maid Status - Cleaning Start via Special Admin. 
    Station
    (Feature Code = 12, Function Code = 1)
    Sending Service Feature 
    Text (Information) to PMS
    0/1 = In Service/Out 
    Service
    When the text is not to be 
    sent to PMS, “1” is assigned 
    to the corresponding bit.
    b2
    Maid Status - Cleaning End via Special Admin. 
    Station
    (Feature Code = 12, Function Code = 2)
    b3
    Maid Status - Inspection End via Special Admin. 
    Station
    (Feature Code = 12, Function Code = 3)
    b4
    Not usedb5
    b6
    b7
    261 00Not used
    INDEX
    (0 – 1023)DATA
    (DATA)
    00 – FF
    (Hex)BIT
    CORRESPONDING
    DATA
    CONTENTS
    DATA
    0/1BIT 
    						
    							CHAPTER 4 NDA-24288
    Page 76
    Revision 1.0
    AHSY
    2620
    b0
    Not used
    Sending Service Feature 
    Text (Information) to PMS
    0/1 = In Service/Out 
    Service
    When the text is not to be 
    sent to PMS, “1” is assigned 
    to the corresponding bit. 0b1
    0b2
    b3
    Message Waiting Lamp - On
    (Feature Code = 13, Function Code = 3)
    b4
    Message Waiting Lamp - Off
    (Feature Code = 13, Function Code = 4)
    0
    b5
    Not used 0b6
    0b7
    263 00Not used
    2640
    b0Not used
    Sending Service Feature 
    Text (Information) to PMS
    0/1 = In Service/Out of 
    Service
    When the text is not to be 
    sent to PMS, “1” assigned to 
    the corresponding bit. 0b1
    b2
    Call Detail Data
    (Feature Code = 14, Function Code = 2)
    b3
    Not used 0
    b4
    0b5
    0b6
    0b7
    265 00Not used
    INDEX
    (0 – 1023)DATA
    (DATA)
    00 – FF
    (Hex)BIT
    CORRESPONDING
    DATA
    CONTENTS
    DATA
    0/1BIT 
    						
    							NDA-24288 CHAPTER 4
    Page 77
    Revision 1.0
    AHSY
    2660
    b0Not used
    Sending a Service Feature 
    Text (Information) to PMS.
    0/1 = In Service/Out 
    Service
    When the text is not to be 
    sent to PMS, “1” assigned to 
    the corresponding bit. 0b1
    b2
    Room Cutoff and Do Not Disturb
    (Feature Code = 15, Function Code = 2)
    b3
    Not used 0
    b4
    0b5
    0b6
    0b7
    267 00Not used
    2680
    b0
    Not used 0b1
    0b2
    0b3
    b4
    Checkout - C.O. line Outgoing Call Report
    (Feature Code = 16, Function Code = 5)
    b5
    Checkout - Message Off Report
    (Feature Code = 16, Function Code = 6)
    0
    b6
    Checkout - Message On Report 
    (Feature Code = 16, Function Code = 6)
    0
    b7Not used
    2690
    b0
    Not used 0b1
    0b2
    0b3
    b4
    Checkout - C.O. line Outgoing Call Report
    (Feature Code = 16, Function Code = C)
    b5
    Checkout - Message Waiting Report
    (Feature Code = 16, Function Code = D)
    0
    b6Not used
    0b7
    INDEX
    (0 – 1023)DATA
    (DATA)
    00 – FF
    (Hex)BIT
    CORRESPONDING
    DATA
    CONTENTS
    DATA
    0/1BIT 
    						
    							CHAPTER 4 NDA-24288
    Page 78
    Revision 1.0
    AHSY
    2700
    b0Not used
    Sending a Service Feature 
    Text (Information) to PMS
    0/1 = In Service/Out of 
    Service
    When the text is not to be 
    sent to PMS, “1” is assigned 
    to the corresponding bit. 0b1
    b2
    Room Data Image - Room Data Report
    (Feature Code = 17, Function Code = 2)
    0
    b3Not used
    b4
    Room Data Image - Room Data Exchange
    (Feature Code = 17, Function Code = 4)
    0
    b5Not used
    b6
    Room Data Image - Room Data Report
    (Feature Code = 17, Function Code = 6)
    0
    b7Not used
    271
    b0
    Room Data Image - Room Data Exchange
    (Feature Code = 17, Function Code = 8)
    0
    b1Not used
    b2
    Room Data Image - Room Data Report
    (Feature Code = 17, Function Code = A)
    0
    b3Not used
    b4
    Room Data Image - Room Data Exchange
    (Feature Code = 17, Function Code = C)
    0
    b5Not used
    b6
    Station Delete Report
    (Feature Code = 17, Function Code = E)
    b7
    Station Delete Report
    (Feature Code = 17, Function Code = F)
    272 00
    Not used
    273 00
    Not used
    INDEX
    (0 – 1023)DATA
    (DATA)
    00 – FF
    (Hex)BIT
    CORRESPONDING
    DATA
    CONTENTS
    DATA
    0/1BIT 
    						