    							NDA-24288 CHAPTER 4
    Page 229
    Revision 1.0
    ASPS
    (k) Paging Answer Code (SRV = PAGA)
    DAY/NIGHT
    (D/N)
    D/NASSIGN NUMBER
    (No.)
    0 – 63DEVELOP
    NUMBER
    (F)
    0 – 15KIND OF SERVICE
    (SRV)ROUTE NUMBER
    (RT) 
    PA G A
    PA G A
    PA G A
    PA G A
    PA G A
    PA G A
    PA G A
    PA G A
    PA G A
    PA G A
    PA G A
    PA G A
    PA G A
    PA G A
    PA G A 
    						
    							CHAPTER 4 NDA-24288
    Page 230
    Revision 1.0
    ASPS
    (l) Paging Cancel Code (SRV = PAGC)
    DAY/NIGHT
    (D/N)
    D/NASSIGN NUMBER
    (No.) 
    0 – 63DEVELOP
    NUMBER
    (F) 
    0 – 15KIND OF SERVICE
    (SRV) ROUTE NUMBER
    (RT)
    PA G C
    PA G C
    PA G C
    PA G C
    PA G C
    PA G C
    PA G C
    PA G C
    PA G C
    PA G C
    PA G C
    PA G C
    PA G C
    PA G C
    PA G C 
    						
    							NDA-24288 CHAPTER 4
    Page 231
    Revision 1.0
    ASCR
    ASCR: Assignment of Station Connection Restriction
    1. General
    This command assigns and displays the station-to-station connection restriction data based on the Route
    Restriction Class (RSC) of respective tenants.
    2. Precautions
    1. This command is used for the Hotel Application only.
    2. Station-to-station connections will be allowed for each RSC until they are restricted by this command.
    3. Data Entry Instructions
    CALLING TN
           RSC
    Calling Tenant Number
               respective Route Restriction ClassDIAL/ATT
    Designate whether restriction applies
    to stations or attendant
    0/1 = Dial/Attendant
     CALLING
      TENANT
     NUMBER
    (CALLING
         TN)    CALLING
    RESTRICTION
          CLASS
       (RSC) 0-15    CALLED
    RESTRICTION
         CLASS
      (RSC) 0-15 DAY/NIGHT
        MODE
         (D/N)
           D/N   DIRECT
    DIAL FROM
      STA/ATT
     (DIAL/ATT)
           0/1RESTRICTION
     RESTRICTED
       /ALLOWED
            (RES)
              0/1
    CALLED TN
          RSC
    Called Tenant Number
                 respective Route Restriction ClassD/N
    RES
    D : Day Mode
    N : Night Mode0 : Restricted
    1 : Connection is allowed      
      CALLED
      TENANT
     NUMBER
    (CALLED
         TN)
      
    						
    							CHAPTER 4 NDA-24288
    Page 232
    Revision 1.0
    ASCR
    4. Data Sheet
    CALLING
    TENANT
    NUMBER
    (CALLING
    TN)CALLED
    TENANT
    NUMBER
    (CALLED
    TN)CALLING
    RESTRICTION
    CLASS
    (RSC)
    0 – 15CALLED
    RESTRICTION
    CLASS
    (RSC)
    0 – 15DAY /NI GHT
    MODE
    (D/N)
    D/NDIRECT DIAL
    FROM STA/ATT
    (DIAL/ATT)
    1/2RESTRICTION
    RESTRICTED/
    ALLOWED
    (RES)
    0/1 
    						
    							NDA-24288 CHAPTER 4
    Page 233
    Revision 1.0
    AT C R
    ATCR:    Assignment of Telephone Class Restriction
    1. General
    This command assigns and displays the restriction data for connections between Telephone Equipment Classes
    (TECs).
    2. Precautions
    1. This command is used for the Hotel Application only.
    2. Connection between TECs will be allowed for each RSC until they are restricted by this command.
    3. TEC 31 is used for ATT in this command.
    3. Data Entry Instructions
    CALLING TEC
    Calling Telephone Equipment Class
    1: DP (10 pps) 2: PB
    3: DP/PB 4: DP (20 pps)
    5: DP (10 pps) : Guest 6: PS : Guest
    7: DP/PB : Guest 8: DP (20 pps) : Guest
    9: House Phone 10: House Phone : Guest
    11: Not Used 12: D
    term       
    13: Data Terminal via Dterm14: Hot Line
    15: CAS Line 16: Data Terminal via Data Module
    17: Not Used 18: Virtual Line Appearance (for D
    term Multi-Line)
    19-22: Not Used 23: ISDN Terminal
    24-25: Not Used 26: Not Used
    27: Eight Conference Equipment
    28-30: Not Used 31:ATT    
    CALLED TEC
    Called Telephone Equipment Class
    1 : DP (10 pps) 2 : PB
    3 : DP/PB 4 : DP (20 pps)
    5 : DP (10 pps) : Guest
     6 : PS : Guest
    7 : DP/PB : Guest 8 : DP (20 pps) : Guest
    9 : House Phone 10 : House Phone : Guest
    11 : Not Used 12 : D
    term       
    13 : Data Terminal via Dterm14 : Hot Line
    15 : CAS Line1 6 : Data Terminal via Data Module
    17 : Not Used 18 : Virtual Line Appearance (for D
    term Multi-Line)
    19-22 : Not Used 23 : ISDN Terminal
    24-25 : Not Used 26 : Not Used
    27 : Eight Conference Equipment
    28-30 : Not Used 31 : ATT    
         CALLING
      TELEPHONE
     EQUIP. CLASS
    (CALLING TEC)
             1-31     CALLED
      TELEPHONE
     EQUIP. CLASS
    (CALLED TEC)
             1-31DAY/NIGHT
         MODE
          (D/N)   
           D/NRESTRICTION
           (RES)
             0/1
    RES
    0 : Restricted
    1 : Connection is allowed
    D/N
    D : Day Mode
    N : Night Mode 
    						
    							CHAPTER 4 NDA-24288
    Page 234
    Revision 1.0
    AT C R
    4. Data Sheet
     
    CALLING
     TELEPHONE
     EQUIP. CLASS
    (CALLING TEC)
    1 – 31CALLED
     TELEPHONE
     EQUIP. CLASS
    (CALLED TEC)
    1 – 31DAY/NIGHT MODE
    (D/N)
    D/NRESTRICTION
    (RES)
    0/1 
    						
    							NDA-24288 CHAPTER 4
    Page 235
    Revision 1.0
    ADNR
    ADNR: Assignment of Day/Night Restriction
    1. General
    This command assigns and displays the specific Start and End times pertaining to Day/Night Restriction or to
    display the Day/Night Restriction classification of a specific time.
    2. Precautions
    1. This command is used for the Hotel Application only.
    2. When Data “1” is assigned for bit6 of the ASYD command, SYS1, INDEX 170, Day/Night Connection
    Restriction will be executed regardless of ATT night mode changeover.
    3. The ARSC command may be affected if the day and night tables are used.
    4. For time designation, use military time (24 hour cycle) in units of 10 minutes.
    5. End time must be later than Start time. If the same time is specified for both Start and End, the restriction
    period will be 10 minutes.
    6. Night time assignment should be input twice; once for the period before midnight, and once for the period
    after midnight because midnight is assigned as hour 00:00. Refer to the example below for clarification:
    Example:If the time period from 9:00 p.m. to 7:00 a.m. is to be assigned as Night,
    00:00 - 07:00 = Night
    07:10 - 20:50 = Day
    21:00 - 23:50 = Night
    7. RSC 11 through 15 may be used in the Same Special Code Time Zone Connection Change service (The
    AASP/AGSP command, SRV = 2, SID 36, STATE 51- 55).
    3. Data Entry Instructions
    D/N RSC
    TENANT
    NUMBER 
        (TN)DAY/NIGHT
        MODE
         (D/N)
          D/N      ROUTE
    RESTRICTION
          CLASS
           (RSC)
            0-15RESTRICTION
      START TIME
     (START TIME)  
       00:00-23:50RESTRICTION
        END TIME
       (END TIME)
       00:00-23:50
    START TIMEEND TIME D : Day Mode
    N : Night ModeRSC 0      : ATT
    RSC 1-15 : Station
    Assign in military time (24 hour cycle)
    in units of 10 minutes.Assign in military time (24 hour cycle)
    in units of 10 minutes. 
    						
    							CHAPTER 4 NDA-24288
    Page 236
    Revision 1.0
    ADNR
    4. Data Sheet
    TENANT
    NUMBER
    (TN)DAY /NI GHT
    MODE
    (DAY/NIGHT)
    D/NROUTE
    RESTRICTION CLASS
    (RSC)
    0 – 15RESTRICTION
     START TIME
     (START TIME)
    00:00 – 23:50RESTRICTION
    END TIME
     (END TIME)
     00:00 – 23:50
    ::
    ::
    ::
    ::
    ::
    ::
    ::
    ::
    ::
    ::
    ::
    ::
    ::
    ::
    ::
    ::
    ::
    ::
    ::
    ::
    ::
    ::
    ::
    ::
    ::
    :: 
    						
    							NDA-24288 CHAPTER 4
    Page 237
    Revision 1.0
    AAST
    AAST: Assignment of Administration Station Data
    1. General
    This command assigns the administration station data. 
    2. Precautions
    1. This command is used for the Hotel Application only.
    2. When deleting station data, use the RAST command.
    3. The AASN command is used to change the station number, and the AACL command is used to change the
    Class data (TEC, RSC, SFC etc.).
    4. Assignment of Room Class 15 is not available.
    5. The number of digits for a station number are designated by the ASYD command, SYS1, INDEX 16. The
    maximum number of digits for a station is 6.
    6. The first digit of the station number is designated by the AANP command.
    7. The RSC and SFC data work in conjunction with ARSC/ASCR/ADNR and ASFC commands. 
    						
    							CHAPTER 4 NDA-24288
    Page 238
    Revision 1.0
    AAST
    3. Data Entry Instructions
      1 : DP (10 pps) 2 : PB      
      3 : DP/PB 4 : DP (20 pps)
      5-8 : Not Used 9 : House Phone               
     10-11 : Not Used 12 : D
    term
      13 : Data Terminal via Dterm                  
      14 : Hot Line1 5 : CAS Line
      16 : Data Terminal via Data Module               
     17 : Not Used
      18 : Virtual Line Appearance (for D
    term Multi-Line)
      19-22 : Not Used 23 : ISDN Terminal       
      24-25 : Not Used 26 : Not Used
      27 : Eight Conference Equipment                
     28-31 : Not UsedTEC
    LENS
    Enter the LENS
    XX X XX X
                                               Level No. (0-7)
                                               Group No. (00-31)
                                               Unit No. (0-3)
                                               Module Group No. (00-31)
    G
    0 : Ground
    1 : Underground
    TENANT
    NUMBER
       (TN)    STATION
      NUMBER
         (STN)
    Max.6 digitsTELEPHONE
    EQUIPMENT
        CLASS
         (TEC)
          1-31     ROUTE
    RESTRICTION
         CLASS
          (RSC)
           0-15SERVICE
    FEATURE
      CLASS
       (SFC)
        0-15ROOM
    CLASS
       0-15ANNEX
     (ANX)
       0-3    GROUND/
    UNDERGROUND 
               (G)
               0/1FLOOR
      (FLR)
      1-127 LINE EQUIPMENT
           NUMBER
             (LENS)
    MG      U       G       LV
    ANNEX
    0 : Main Building
    1 : Annex 1
    2 : Annex 2
    3 : Annex 3
    RSC
    Enter the RSC defined by the ARSC command. Since RSC = 0 is
    preserved for ATTCON, a station can use the RSC range from 1 to 15.
    SFC
    Enter the SFC defined by the ASFC command. Since SFC = 0 is
    preserved for ATTCON, a station can use the SFC range from 1 to 15.
    0 : General Administration  (Ordinary Telephone, D
    term)    
    1-5 : Not used
    6 : Guest Service Telephone (D
    term and External Equipment)
    7-15 : Not UsedRoom Class STN
    Enter the station number with regard to the following:
     The number of station number (STN) digits is designated
       by the ASYD command, SYS1, INDEX 16. 
    						