Home > NEC > Communications System > NEC Neax 2400 Imx Hotel Office Data Specification

NEC Neax 2400 Imx Hotel Office Data Specification

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2400 Imx Hotel Office Data Specification online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							NDA-24288 CHAPTER 2
    Page 29
    Revision 1.0
    ASSIGNMENT
    Figure 2-22   Network Control Data Assignment Flow Chart (2/2)
    TrunkATRKMBTKAMATASATATGLAAKP
    ATRKMBTK
    Service
    CCIS No. 7
    ISDN
    ASHPASHCASHUAUCDAUOGAUADACPGACPE
    AISAAISDASGDASIDACFSASLU1ASLU2
    ACSAACSIANCDATASAEKDAANDAANDE
    ASPDAATCACFO
    ARPCARDN
    ACDDACNPACNDAFCPACBCAVTCAVTL
    ACNPNACNDN
    AEVT
    Internal TrunkATT
    External TrunkORT / IRT / SND / CFT:ACOC
    APAD
    AAED
    ADPC
    ADPCACSC
    ACSC
    AAEDL
    ACIC1
    ACIC1
    ARTI
    ACIC2
    ARTDATRKMBTKPSTN         :
    TIE LINE   :       
    DAT           :
    CCIS No.7  :         
    ISDN          :
    Station:
    PSTN  :
    Others:
    Service:
    Service:
    ACRDACTKMBCTAFCHAFRTAFPCACANATDF
    ATDFACRDACTKMBCTAFPCACAN
    Fusion LinkFCCH:
    Ether:
    AAEDNAHMS
    ACID
    APADN
    ADPCLACSCL
    ARTIN
                                 :
    ASDTASTNAPHNAPHNLAPHNNANDD
    ASCL
    AKYDAFDDADSLADKSADRTN
    AIZPAICDADIM
    AHLSASPD
    ADA2AFCD
    ALGSL
    Station Number
    Service For Station:
    (Physical STA No.) For Telephone Number:
    For Dterm SeriesE:
    ALGSNATSTN
    For Service:
    For Hot Line:
    For Data:See(Available in the self node only)
    (Available in all nodes of the Fusion network.)
    ASHPNASHCNASHUNAUCDNAUOGNAUADNACPGNACPEN
    ASHPLASHCLACPGLACPEL
    ADPCL 
    						
    							CHAPTER 2 NDA-24288
    Page 30
    Revision 1.0
    ASSIGNMENT
    3. Hotel Command
    Figure 2-23   Hotel Command Data Assignment Flow Chart (1/2)
    Figure 2-23   Hotel Command Data Assignment Flow Chart (2/2)
    ASYD System BaseASYDLAHSYAUNTAIOCAPSWATIMASTDAOFC
    AUIDN
    AASTAASNAPHNANDDAKYD
    RAST
    AACL
    Sys1 Index512 - 1535
    Sys1 Index0 - 511 ,  Sys2 Index0  - 15 & Sys3 Index0 - 31
    Numbering Plan
    Network Numbering
    Restriction
    Station Number
    Trunk:        Same as the Business Command
    Service         :
    STA - STA     :
    Day / Night     :
    AGSTAGSNAHSU
    RGST
    AKYD
    AGCL
    AANPAASP
    AGNPAGSP
    ASPS
    ASFC
    ASCRATCR
    ADNR Administration:
    Guest               :
    Same as the Business Command
    Administration       :
    Guest                    :STA No.
    STA No.
    ATRK MBTK AMAT ASAT AAKP ADSS
    AAED AHMS
    ASPF
    ADLI AFXC Tr u n k
    Service
    same as the Business CommandExternal Trunk:
    ATT:
    DAT:
    Hotel: 
    						
    							NDA-24288 CHAPTER 3
    Page 31
    Revision 1.0
    CHAPTER 3 OFFICE DATA DESIGN SHEET
    Office data design sheets are used to design the configuration and specification of IMX.
    1. Trunking Diagram
    The Trunking diagram shows the system configuration and the number of lines.
    2. Bay Face Layout
    The Bay Face layout shows the circuit card mounting slots.
    3. Port Location Table
    A Port Location table denotes the Line/Trunk circuit cards located in each Universal Slot of PIM.
    4. Numbering Plan Table
    Area Codes for various service features are determined according to the Dial Access Numbering Plan. There are
    three types of Dial Access Numbers.
    Station Access Numbers
    Special Service Access Numbers
    Trunk Access Numbers
    5. Restriction Tables
    1. Service Feature Restriction Class
    2. Trunk Restriction Class Table
    3. Tenant Restriction Tables 
    						
    							CHAPTER 3 NDA-24288
    Page 32
    Revision 1.0
    OFFICE DATA DESIGN SHEET
    Figure 3-1   Trunking Diagram
    PFT
    LC MDF
    DLC/ELC
    DLC
    DTL
    COT
    COT
    COT
    DID
    EMT
    DID
    TLT
    DTI
    RST
    MFCT
    DTI
    CCHMODEM
    DTI (PRI)
    DCH
    ATI
    RGU
    HWU
    LTST
    1
    HUB
    TO MAT
    CCH
    PRINTER ATT/DESK CONSOLE
    IOCCPROSC/PLO
    MAINTENANCE
    ADMINISTRATION
    TERMINAL (MAT)
    SUBSCRIBER
    D
    termW/O DATA ADAPTER
    DtermWITH DATA ADAPTER
    FROM/TO
    CENTRAL OFFICE
    FROM/TO TIE LINE
    FROM/TO CCIS LINE
    FROM/TO ISDN LINE
    (PRI) 
     
    Note: Table 3-1 identifies the function name of each circuit card. BWT
    DOD
    DIT
    DIDMUX
    TSW 
    						
    							NDA-24288 CHAPTER 3
    Page 33
    Revision 1.0
    OFFICE DATA DESIGN SHEET
    Table 3-1 identifies the function name of each circuit card used for the system.
    Table 3-1 Circuit Card Function Name
    SYMBOL DESCRIPTION
    ATI Attendant Console Interface
    BWT Bothway Trunk
    CCH Common Channel Handler
    CFT Conference Trunk
    COT Central Office Trunk
    CPR Central Processing Rack
    DCH D Channel Handler
    DID Direct Inward Dialing
    DIT Direct-In Termination
    DLC Digital Line Circuit
    DOD Direct Outward Dialing
    D
    termDigital Multi-Function Telephone
    DTI Digital Interface
    DTL Data Terminal Line Circuit
    ELC Electronic Line Circuit
    EMT Equipment & Maintenance Trunk
    HWU Howler Tone Unit
    IOC Input/Output Controller
    LC Line Circuit
    LT S T L i n e  Te s t
    MDF Main Distribution Frame
    MFCT Multi-frequency Trunk
    MUX Multiplexer
    ODT Office Data Trunk
    OSC Oscillator for 1-IMG
    PFT Power Failure Transfer
    PLO Phase Lock Oscillator for 4-IMG/IMX-U
    RGU Ringing Generator Unit
    RST Register Sender Trunk
    TLT Tie Line Trunk
    TSW Time Switch 
    						
    							CHAPTER 3 NDA-24288
    Page 34
    Revision 1.0
    OFFICE DATA DESIGN SHEET
    Figure 3-2   Card Mounting Slot
    00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A (PWR0)PA-PW54-A (PWR1)PH-PC36 (MUX) PH-PC36 (MUX)
    PH-SW10 (TSW) PH-SW10 (TSW)
    PIM3
    00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A (PWR0)PA-PW54-A (PWR1)PH-PC36 (MUX) PH-PC36 (MUX)
    PIM2
    00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A (PWR0)PA-PW54-A (PWR1)PH-PC36 (MUX) PH-PC36 (MUX)
    PIM1
    00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A (PWR0)PA-PW54-A (PWR1)
    PIM0
    LPM
    PH-IO24 (IOC) PH-PC40 (EMA)
    00  01   02  03  04 
    Note:The second IOC (PH-IO24) can be mounted in slot number 02 of the LPM. 
    						
    							NDA-24288 CHAPTER 3
    Page 35
    Revision 1.0
    OFFICE DATA DESIGN SHEET
    Figure 3-3   Card Mounting Slot for 4-IMG System (1/4)
    00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A(PWR0)PA-PW54-A(PWR1)PH-PC36(MUX) PH-PC36(MUX)
    PH-PC36(MUX) PH-PC36(MUX)
    PIM3
    00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A(PWR0)PA-PW54-A(PWR1)PH-PC36(MUX) PH-PC36(MUX)
    PIM2
    00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A(PWR0)PA-PW54-A(PWR1)PH-PC36(MUX) PH-PC36(MUX)
    PIM1
    00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A(PWR0)PA-PW54-A(PWR1)
    PIM0
    BSCM
    LPM
    PH-IO24(IOC) PH-PC40(EMA)00  01   02  03  04 (IOC/MISC)
    (MISC)
    (MISC)
    PIM
    PIM
    PIM
    PIM
    IMG3 DummyPIM
    PIM
    PIM
    PIM
    IMG2 DummyPIM
    PIM
    PIM
    PIM
    IMG1 TSWMPIM
    PIM
    PIM
    PIM
    IMG0LPM
    B
    S
    C
    M IMG0 4-IMG SYSTEM 
    						
    							CHAPTER 3 NDA-24288
    Page 36
    Revision 1.0
    OFFICE DATA DESIGN SHEET
    Figure 3-3   Card Mounting Slot for 4-IMG System (2/4)
    00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A(PWR0)PA-PW54-A(PWR1)PH-PC36(MUX) PH-PC36(MUX)
    PH-PC36(MUX) PH-PC36(MUX)
    PIM3
    00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A(PWR0)PA-PW54-A(PWR1)PH-PC36(MUX) PH-PC36(MUX)
    PIM2
    00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A(PWR0)PA-PW54-A(PWR1)PH-PC36(MUX) PH-PC36(MUX)
    PIM1
    00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A(PWR0)PA-PW54-A(PWR1)
    PIM0
    00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PH-PW14(PWRSW) PH-PW14(PWRSW) PH-PC20(DLKC0) PH-PC20(DLKC1)
    PH-GT09(GT0)
    PH-GT09(GT1)
    PH-SW12(TSW00)
    PH-SW12(TSW01)
    PH-SW12(TSW02)
    PH-SW12(TSW03)
    PH-SW12(TSW10)
    PH-SW12(TSW11)
    PH-SW12(TSW12)
    PH-SW12(TSW13) PH-CK16/17(PLO0)
    PH-CK16/17(PLO1)
    (MISC) (MISC)
    (MISC)
    (MISC)
    (MISC)
    (MISC)
    TSWM
    PIM
    PIM
    PIM
    PIM
    IMG3 DummyPIM
    PIM
    PIM
    PIM
    IMG2 DummyPIM
    PIM
    PIM
    PIM
    IMG1 TSWMPIM
    PIM
    PIM
    PIM
    IMG0LPM
    B
    S
    C
    M IMG1 4-IMG SYSTEM
         
    						
    							NDA-24288 CHAPTER 3
    Page 37
    Revision 1.0
    OFFICE DATA DESIGN SHEET
    Figure 3-3   Card Mounting Slot for 4-IMG System (3/4)
    00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A(PWR0)PA-PW54-A(PWR1)PH-PC36(MUX) PH-PC36(MUX)
    PH-PC36(MUX) PH-PC36(MUX)
    PIM3
    00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A(PWR0)PA-PW54-A(PWR1)PH-PC36(MUX) PH-PC36(MUX)
    PIM2
    00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A(PWR0)PA-PW54-A(PWR1)PH-PC36(MUX) PH-PC36(MUX)
    PIM1
    00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A(PWR0)PA-PW54-A(PWR1)
    PIM0
    00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23
    Dummy
    PIM
    PIM
    PIM
    PIM
    IMG3 DummyPIM
    PIM
    PIM
    PIM
    IMG2 DummyPIM
    PIM
    PIM
    PIM
    IMG1 TSWMPIM
    PIM
    PIM
    PIM
    IMG0LPM
    B
    S
    C
    M IMG2 4-IMG SYSTEM
         
    						
    							CHAPTER 3 NDA-24288
    Page 38
    Revision 1.0
    OFFICE DATA DESIGN SHEET
    Figure 3-3   Card Mounting Slot for 4-IMG System (4/4)
    00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A(PWR0)PA-PW54-A(PWR1)PH-PC36(MUX) PH-PC36(MUX)
    PH-PC36(MUX) PH-PC36(MUX)
    PIM3
    00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A(PWR0)PA-PW54-A(PWR1)PH-PC36(MUX) PH-PC36(MUX)
    PIM2
    00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A(PWR0)PA-PW54-A(PWR1)PH-PC36(MUX) PH-PC36(MUX)
    PIM1
    00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A(PWR0)PA-PW54-A(PWR1)
    PIM0
    00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23
    Dummy
    PIM
    PIM
    PIM
    PIM
    IMG3 DummyPIM
    PIM
    PIM
    PIM
    IMG2 DummyPIM
    PIM
    PIM
    PIM
    IMG1 TSWMPIM
    PIM
    PIM
    PIM
    IMG0LPM
    B
    S
    C
    M IMG3 4-IMG SYSTEM 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2400 Imx Hotel Office Data Specification