NDA-24288 CHAPTER 4 Page 79 Revision 1.0 AHSY 2740 b0Not used Sending a Service Feature Text (Information) to PMS 0/1 = In Service/Out of Service When the text is not to be sent to PMS, “1” is assigned to the corresponding bit. b1 Automatic Wake-Up is set (Feature Code = 19, Function Code = 1) b2 Automatic Wake-Up is canceled (Feature Code = 19, Function Code = 2) b3 Automatic Wake-Up Result (Feature Code = 19, Function Code = 3) 0 b4Not used 0b5 b6 Automatic Wake-Up (Group Announcement) is set (Feature Code = 19, Function Code = 6) b7 Automatic Wake-up (Group Announcement) is set (Feature Code = 19, Function Code = 7) 275 b0 Automatic Wake-Up (Group Announcement) is set (Feature Code = 19, Function Code = 8) 0 b1 Not used 0 b2 0b3 0b4 0b5 0b6 0b7 276 00Not used 277 00 Not used 278 00 Not used 279 00 Not used 280 00 Not used 281 00 Not used 282 00 Not used 283 00 Not used INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT
CHAPTER 4 NDA-24288 Page 80 Revision 1.0 AHSY 284 00 Not used 285 00 Not used 286 00 Not used 287 00 Not used 288 00 Not used 289 00 Not used 290 00 Not used 291 00 Not used 2920 b0Not used Sending Service Feature Text (Information) to PMS 0/1 = In Service/Out Service When the text is not to be sent to PMS, “1” is assigned to the corresponding bit. b1 Check-In via a Dterm (Feature Code = 46, Function Code = 1) 0 b2Not used b3 Bill Inquiry via a Dterm (Feature Code = 46, Function Code = 3) 0 b4Not used 0 b5 Checkout via a Dterm (Feature Code = 46, Function Code = 5) 0 b6Not used 0b7 293 00Not used 294 00 Not used 295 00 Not used 296 00 Not used 297 00 Not used 298 00 Not used 299 00 Not used 300 00 Not used 301 00 Not used INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT
NDA-24288 CHAPTER 4 Page 81 Revision 1.0 AHSY 302 b0Not used b1 Maid Status - Guest Room 1 (Feature Code = 51, Function Code = 1) Sending Service Feature Text (Information) to PMS 0/1 = In Service/Out of Service When the text is not to be sent to PMS, “1” is assigned to the corresponding bit. Note:These Texts are used for Maid Status Answer Back System. b2 Maid Status - Guest Room 2 (Feature Code = 51, Function Code = 2) b3 Maid Status - Guest Room 3 (Feature Code = 51, Function Code = 3) b4 Maid Status - Guest Room 4 (Feature Code = 51, Function Code = 4) b5 Maid Status - Guest Room 5 (Feature Code = 51, Function Code = 5) b6 Maid Status - Guest Room 6 (Feature Code = 51, Function Code = 6) 0 b7Not used 303 00 Not used 3040 b0 b1 Maid Status - Admin. 1 (Feature Code = 52, Function Code = 1)Sending Service Feature Text (Information) to PMS 0/1 = In Service/Out of Service When the text is not to be sent to PMS, “1” is assigned to the corresponding bit. Note:These Texts are used for Maid Dial Answer Back System. b2 Maid Status - Admin. 2 (Feature Code = 52, Function Code = 2) b3 Maid Status - Admin. 3 (Feature Code = 52, Function Code = 3) b4 Maid Status - Admin. 4 (Feature Code = 52, Function Code = 4) 0 b5 Not used 0b6 0b7 305 00Not used INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT
CHAPTER 4 NDA-24288 Page 82 Revision 1.0 AHSY 306 b0Not used Sending Service Feature Text (Information) to PMS 0/1 = In Service/Out of Service When the text is not to be sent to PMS, “1” is assigned to the corresponding bit.b1 b2 Message Waiting Lamp On via a Dterm (Feature Code = 53, Function Code = 2) b3 Message Waiting Lamp On via a Dterm (Feature Code = 53, Function Code = 3) b4 Not usedb5 b6 b7 307 00 3080 b0Not used b1 Call Detail Data (Feature Code = 54, Function Code = 1)Sending Service Feature Text (Information) to PMS 0/1 = In Service/Out of Service When the text is not to be sent to PMS, “1” is assigned to the corresponding bit. 0 b2 Not used 0 b3 0b4 0b5 0b6 0b7 309 00Not used 310 00 Not used 311 00 Not used INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT
NDA-24288 CHAPTER 4 Page 83 Revision 1.0 AHSY 3120 b0 Not used Sending Service Feature Text (Information) to PMS 0/1 = In Service/Out of Service When the text is no to be sent to PMS, “1” is assigned to the corresponding bit. 0 b1 0b2 0b3 0b4 0b5 0b6 b7 Provisional Check-In (Feature Code = 56, Function Code = 7) 313 b0 Provisional Checkout (Feature Code = 56, Function Code = 8) b1 Checkout Message Waiting Report (Feature Code = 56, Function Code = 9) 0 b2 Not used 0 b3 0b4 0b5 0b6 0b7 314 00Not used 315 00 Not used 316 00 Not used 317 00 Not used 318 00 Not used 319 00 Not used 320 00 Not used 321 00 Not used 322 00 Not used 323 00 Not used INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT
CHAPTER 4 NDA-24288 Page 84 Revision 1.0 AHSY 3240 b0Not used Sending Service Feature Text (Information) to PMS 0/1 = In Service/Out of Service When the text is not to be sent to PMS, “1” is assigned to the corresponding bit. 0b1 b2 Guest Room Secretary Telephone Setting/ Cancellation (Feature Code = 62, Function Code = 2) 0 b3 Not used 0 b4 0b5 0b6 0b7 325 00Not used 326 00 Not used 327 00 Not used 328 00 Not used 329 00 Not used 330 00 Not used 331 00 Not used 332 00 Not used 333 00 Not used 334 00 Not used 335 00 Not used 336 00 Not used 337 00 Not used 338 00 Not used 339 00 Not used 340 00 Not used 341 00 Not used 342 00 Not used 343 00 Not used 344 00 Not used 345 00 Not used 346 00 Not used 347 00 Not used 348 00 Not used 349 00 Not used INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT
NDA-24288 CHAPTER 4 Page 85 Revision 1.0 AHSY 350 00 Not used 351 00 Not used 352 00 Not used 353 00 Not used 354 00 Not used 355 00 Not used 356 00 Not used 357 00 Not used 358 00 Not used 359 00 Not used 360 b0 Digits Code 0 Outgoing Call Access Code No. 1Note:When the dial access code contains “0,” enter “A” for “0.” Example: When the dial access code is “9- 202”. b 1 b2 b3 b4 Digits Code 1b5 b6 b7 361 b0 Digits Code 2b1 b2 b3 b4 Digits Code 3b5 b6 b7 INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT 29 2 A
CHAPTER 4 NDA-24288 Page 86 Revision 1.0 AHSY 362 b0 Digits Code 0 Outgoing Call Access Code No. 2Note:When the dial access code contains “0,” enter “A” for “0.” Example: When the dial access code is “9- 202”. b 1 b2 b3 b4 Digits Code 1b5 b6 b7 363 b0 Digits Code 2b1 b2 b3 b4 Digits Code 3b5 b6 b7 364 b0 Digits Code 0 Outgoing Call Access Code No. 3Note:When the dial access code contains “0,” enter “A” for “0.” Example: When the dial access code is “9- 202”. b 1 b2 b3 b4 Digits Code 1b5 b6 b7 365 b0 Digits Code 2b1 b2 b3 b4 Digits Code 3b5 b6 b7 INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT 29 2 A 29 2 A
NDA-24288 CHAPTER 4 Page 87 Revision 1.0 AHSY 366 b0 Digits Code 0 Outgoing Call Access Code No. 4Note:When the dial access code contains “0,” enter “A” for “0.” Example: When the dial access code is “9- 202”. b 1 b2 b3 b4 Digits Code 1b5 b6 b7 367 b0 Digits Code 2b1 b2 b3 b4 Digits Code 3b5 b6 b7 368 00Not used 369 00 Not used 370 00 Not used 371 00 Not used 372 00 b 0~b7Not used 375 00 b 0~b7Not used INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT 29 2 A ~
CHAPTER 4 NDA-24288 Page 88 Revision 1.0 AHSY 3760 b0Not used Text sent to PMS printout 0/1 = Not Required/ Required If “1” assigned to the corresponding bit, the text is output to the Hotel printer. Note:When a failure occurs in a data link between the NEAX2400 IMX and the PMS, the error information is printed. b1Maid Status - Guest (Feature Code = 11) b2Maid Status - Admin. (Feature Code = 12) b3 Message Waiting Lamp (Feature Code = 13) 0 b4Not used b5 Room Cut Off and Do Not Disturb (Feature Code = 15) b6 Check In/Checkout (Feature Code = 16) b7 Room Data Image (Feature Code = 17) 377 00 Not used 378 b0 Room Change and Room Swap (Feature Code = 20)Text sent to PMS printout 0/1 = Not Required/ Required If “1” is assigned to the corresponding bit, the text is output to the Hotel printer. Note:When a failure occurs in a data link between the NEAX2400 IMX and the PMS, the error information is printed. b1 Room Data Change (Feature Code = 21) 0 b2 Not used 0 b3 0b4 0b5 0b6 0b7 379 00Not used 380 00 Not used 381 00 Not used 382 00 Not used 383 00 Not used 384 00 Not used 385 00 Not used 386 00 Not used INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT