    4. Data Sheet
    TENANT 
    NUMBER 
    (TN)STATION NUMBER
    (STN)
    MAXIMUM
    6 DIGITSLINE EQUIPMENT NUMBER (LENS)TELEHONE 
    EQUIPMENT 
    CLASS 
    (TEC)
    1 – 31ROUTE 
    RESTRICTION 
    CLASS 
    (RSC)
    0 – 15SERVICE 
    FEATURE 
    CLASS
     (SFC)
    0 – 15ROOM CLASS 
    (ROOM 
    CLASS)
    0 – 15ANNEX
    (ANX)
    0 – 3GROUND/
    UNDERGROUND 
    (G)
    0/1FLOOR 
    (FLR)
    1 – 127
    MG U G LV 
    						
    							CHAPTER 4 NDA-24288
    Page 240
    Revision 1.0
    AGST
    AGST:    Assignment of Guest Station Data
    1. General
    This command assigns and deletes Guest Room Data. 
    2. Precautions
    1. This command is used for the Hotel Application only.
    2. The AGSN command changes the station number, and the AGCL command changes the Class data (TEC,
    RSC, SFC, etc.).
    3. Only Telephone Equipment Classes (TECs) 5-8, 10, and 12 may be assigned Guest station.
    4. The number of digits for a station number are designated by the ASYD command, SYS1, INDEX 16.
    5. The maximum number of digits for a station is 6.
    6. The first digit of a station number is designated by the AGNP command.
    7. The RSC and SFC data work in conjunction with ARSC/ASCR/ADNR and ASFC commands. 
    						
    							NDA-24288 CHAPTER 4
    Page 241
    Revision 1.0
    AGST
    3. Data Entry Instructions
    TEC
    LENS
    Enter the LENS
    XX X XX X
                                               Level No. (0-7)
                                               Group No. (00-31)
                                               Unit No. (0-3)
                                               Module Group No. (00-31)
    G
    0 : Ground
    1 : Underground
    TENANT
    NUMBER
       (TN)    STATION
      NUMBER
         (STN)
    Max. 6 digitsTELEPHONE
    EQUIPMENT
        CLASS
         (TEC)
          1-31     ROUTE
    RESTRICTION
         CLASS
          (RSC)
           0-15SERVICE
    FEATURE
      CLASS
       (SFC)
        0-15ROOM
    CLASS
       0-15ANNEX
     (ANX)
       0-3    GROUND/
    UNDERGROUND 
               (G)
               0/1FLOOR
      (FLR)
      1-127 LINE EQUIPMENT
           NUMBER
             (LENS)
    MG      U       G       LV
    ANNEX
    0 : Main Building
    1 : Annex 1
    2 : Annex 2
    3 : Annex 3
    RSC
    Enter the RSC defined by the ARSC command. Since RSC = 0 is
    preserved for ATTCON, a station can use the RSC range from 1 to 15.
    SFC
    Enter the SFC defined by the ASFC command. Since SFC = 0 is
    preserved for ATTCON, a station can use the SFC range from 1 to 15
    Imput Data 0-15
    Note:When the D
    term is used for Guest station, 
    ROOM CLASS is fixed to “15”. Room Class STN
    Enter the station number with regard to the following:
     The number of station number (STN) digits is designated
       by the ASYD command, SYS1, INDEX 16.
    Example:0 = Single Room
    1 = Suite Room 1-4 : Not used 5 : DP (10 pps)
    6 : PB 7 : DP/PB
    8 : DP (20 pps) 9 : Not used
    10 : House Phone 11 : Not used               
    12 : D
    term13-31 : Not Used                     
    						
    							CHAPTER 4 NDA-24288
    Page 242
    Revision 1.0
    AGST
    4. Data Sheet
    TENANT
     NUMBER
     (TN)STATION NUMBER
    (STN)
    MAXIMUM
    6 DIGITSLINE EQUIPMENT NUMBER
     (LENS)TELEPHONE
    EQUIPMENT
    CLASS
     (TEC)
    1 – 31ROUTE
    RESTRICTION 
    CLASS (RSC)
    0 – 15SERVICE
    FEATURE
    CLASS
    (SFC)
    0 – 15ROOM
    CLASS
    (ROOM 
    CLASS)
    0 – 15ANNEX
    (ANX)
    0 – 3GROUND/
    UNDER-
    GROUND
    (G)
    0/1FLOOR
    (FLR)
    1 – 127
    MG U G LV 
    						
    							NDA-24288 CHAPTER 4
    Page 243
    Revision 1.0
    AASN
    AASN: Assignment of Alternated Administration Station Number
    1. General
    This command changes a currently assigned Administration Station Number.
    2. Precautions
    1. This command is used for the Hotel Application only. 
    2. Input a number which is not currently assigned. If a station number currently being used is to be assigned
    as a new number, delete the station first via the RAST command.
    3. When the “PKG CHECK” message is displayed during assignment, confirm the LENS location of the
    circuit card (PA-16LC, etc.) accommodating the station, then press the ENTRY key.
    4. When you have changed the station number, update the data sheet for the AAST command.
    3. Data Entry Instructions
    OLD STN
    Enter the current
    station number to be changed.
    TN
    Enter the tenant number of the station.NEW STN
    Enter the new station number according to
    the numbering plan. Update the data sheet for
    the AAST command. TENANT NUMBER (TN)
    NEW STATION NUMBER (NEW STN) OLD STATION NUMBER (OLD STN)  
    						
    							CHAPTER 4 NDA-24288
    Page 244
    Revision 1.0
    AACL
    AACL: Assignment of Administration Station Class
    1. General
    This command changes the data assigned to an Administration Station: Telephone Equipment Class (TEC),
    Service Feature Class (SFC), Route Restriction Class (RSC), ROOM CLASS and Floor Service Data. 
    2. Precautions
    1. This command is used for the Hotel Application only.
    2. Only Telephone Equipment Classes (TECs) 1-4, 12-15, 18-20 and 13 may be assigned via this command.
    3. Floor Service Data is displayed only in the case of the ASYD command, SYS1 INDEX 165, b7 = 1 (Floor
    Service is provided).
    4. When you have changed the station class, update the data sheet for the AAST command. 
    						
    							NDA-24288 CHAPTER 4
    Page 245
    Revision 1.0
    AACL
    3. Data Entry Instructions
    TEC
    RSCANNEX
    G
    NOTE STN
    SFC
    TENANT
    NUMBER
        (TN)  STATION
      NUMBER
         (STN)
    Max. 6 digitsTELEPHONE EQUIPMENT    CLASS
          (TEC)
           1-31      ROUTE
    RESTRICTION
          CLASS
           (RSC)
            0-15SERVICE
    FEATURE
      CLASS
       (SFC)
        0-15ROOM
    CLASS
      0-15ANNEX
     (ANX)
       0-3  
         GROUND/
    UNDERGROUND
               (G)
               0/1FLOOR
     (FLR)
     1-127
    112                           1                           1
    1 : DP (10 pps) 2 : PB 3 : DP/PB 4 : DP (20 pps)
    5-8 : Not Used 9 : House Phone 10-11 : Not Used 12 : Dterm
    13 : Data Terminal via Dterm  14 : Hot Line 15 : CAS Line
    16 : Data Terminal via Data Module 17 : Not Used
    18 : Virtual Line Appearance  (for D
    term Multi-Line)
    19-22 : Not Used 23 : ISDN Terminal 24-25 : Not Used 26 : Not Used
    27 : Eight Conference Equipment 28-31 : Not Used
    Enter the RSC defined by the ARSC/ASCR/ADNR command. Since RSC = 0 is
    preserved for ATTCON, a station  can use the RSC range from 1 to 15.0 : Main Building
    1 : Annex 1
    2 : Annex 2
    3 : Annex 3
    0 : Ground
    1 : Underground
    Enter the station number with regard to the following:
     The number of station number (STN) digits is designated
       by the ASYD command, SYS1, INDEX 16.
    Enter the SFC defined by the ASFC command. Since SFC = 0 is
    preserved for ATTCON, a station can use the SFC range from 1 to 15.When you have changed the station class, update
    the data sheet for the AAST command.
    0 : General Administration (Ordinary Telephone, D
    term) 1-5 : Not Used
    6 : Guest Service Telephone (Dterm and External Equipment)
    7-14 : Not Used 15 : Guest Service Telephone (Dterm)
           
    ROOM CLASS 
    						
    							CHAPTER 4 NDA-24288
    Page 246
    Revision 1.0
    AGSN
    AGSN:    Assignment of Alternated Guest Station Number
    1. General
    This command changes a currently assigned Guest Station Number.
    2. Precautions
    1. This command is used for the Hotel Application only.
    2. Input a number which is not currently assigned. If a station number currently being used is to be assigned
    as a new number, delete the station first via the RGST command.
    3. When the “PKG CHECK” message is displayed during assignment, confirm the LENS location of the
    circuit card (PA-16LC, etc.) accommodating the station, then press the ENTER key.
    4. When you have changed the station number, update the data sheet for the AGST command.
    3. Data Entry Instructions
    OLD STN
    Enter the current
    station number to be changed.
    NEW STN
    Enter the new station number according to
    the numbering plan. Update the data sheet for
    the AGST command. TENANT NUMBER (TN)
    NEW STATION NUMBER (NEW STN) OLD STATION NUMBER (OLD STN) 
    TN
    Enter the tenant 
    number of the station. 
    						
    							NDA-24288 CHAPTER 4
    Page 247
    Revision 1.0
    AGCL
    AGCL: Assignment of Guest Station Class
    1. General
    This command changes the data assigned to a Guest Station: Telephone Equipment Class (TEC), Service
    Feature Class (SFC), Route Restriction Class (RSC), ROOM CLASS and Floor Service Data [Annex (ANX),
    Ground/Underground (G), Floor (FLR)]. 
    2. Precautions
    1. This command is used for the Hotel Application only.
    2. Only Telephone Equipment Classes (TECs) 5-8, 10 and 12 may be assigned via this command.
    3. Floor Service Data is displayed only in the case of the ASYD command, SYS1, INDEX 165, b7 = 1
    (Floor Service is provided).
    4. When you have changed the station class, update the data sheet for the AGST command. 
    						
    							CHAPTER 4 NDA-24288
    Page 248
    Revision 1.0
    AGCL
    3. Data Entry Instructions
    TEC
    RSCANNEX
    G
    NOTE STN
    SFC
    TENANT
    NUMBER
        (TN)  STATION
      NUMBER
         (STN)
    Max. 6 digitsTELEPHONE EQUIPMENT    CLASS
          (TEC)
           1-31      ROUTE
    RESTRICTION
          CLASS
           (RSC)
            0-15SERVICE
    FEATURE
      CLASS
       (SFC)
        0-15ROOM
    CLASS
      0-15ANNEX
     (ANX)
       0-3  
         GROUND/
    UNDERGROUND
               (G)
               0/1FLOOR
     (FLR)
     1-127
    112                           1                           1
    Enter the RSC defined by the ARSC/ASCR/ADNR command. Since RSC = 0 is
    preserved for ATTCON, a station can use the RSC range from 1 to 15.0 : Main Building
    1 : Annex 1
    2 : Annex 2
    3 : Annex 3
    0 : Ground
    1 : Underground
    Enter the station number with regard to the following:
     The number of station number (STN) digits is designated
       by the ASYD command, SYS1, INDEX 16.
    Enter the SFC defined by the ASFC command. Since SFC = 0 is
    preserved for ATTCON, a station can use the SFC range from 1 to 15.When you have changed the station class, update
    the data sheet for the AAST command.
           
    ROOM CLASS
      1-4 : Not Used 5 : DP (10 pps)
      6 : PB 7 : DP/PB
      8 : DP (20pps) 9 : Not Used
     10 : House Phone 11 : Not Used
                   
     
    12 : Dterm 13 : Data Terminal via Dterm 
     14-31: Not Used                   
    0-15
    Note:
    When the D
    term is used for Guest station, 
    ROOM CLASS is fixed to “15”. 
    						