NEC Neax 2400 Imx Hotel Office Data Specification
Have a look at the manual NEC Neax 2400 Imx Hotel Office Data Specification online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
NDA-24288 CHAPTER 4 Page 239 Revision 1.0 AAST 4. Data Sheet TENANT NUMBER (TN)STATION NUMBER (STN) MAXIMUM 6 DIGITSLINE EQUIPMENT NUMBER (LENS)TELEHONE EQUIPMENT CLASS (TEC) 1 – 31ROUTE RESTRICTION CLASS (RSC) 0 – 15SERVICE FEATURE CLASS (SFC) 0 – 15ROOM CLASS (ROOM CLASS) 0 – 15ANNEX (ANX) 0 – 3GROUND/ UNDERGROUND (G) 0/1FLOOR (FLR) 1 – 127 MG U G LV
CHAPTER 4 NDA-24288 Page 240 Revision 1.0 AGST AGST: Assignment of Guest Station Data 1. General This command assigns and deletes Guest Room Data. 2. Precautions 1. This command is used for the Hotel Application only. 2. The AGSN command changes the station number, and the AGCL command changes the Class data (TEC, RSC, SFC, etc.). 3. Only Telephone Equipment Classes (TECs) 5-8, 10, and 12 may be assigned Guest station. 4. The number of digits for a station number are designated by the ASYD command, SYS1, INDEX 16. 5. The maximum number of digits for a station is 6. 6. The first digit of a station number is designated by the AGNP command. 7. The RSC and SFC data work in conjunction with ARSC/ASCR/ADNR and ASFC commands.
NDA-24288 CHAPTER 4 Page 241 Revision 1.0 AGST 3. Data Entry Instructions TEC LENS Enter the LENS XX X XX X Level No. (0-7) Group No. (00-31) Unit No. (0-3) Module Group No. (00-31) G 0 : Ground 1 : Underground TENANT NUMBER (TN) STATION NUMBER (STN) Max. 6 digitsTELEPHONE EQUIPMENT CLASS (TEC) 1-31 ROUTE RESTRICTION CLASS (RSC) 0-15SERVICE FEATURE CLASS (SFC) 0-15ROOM CLASS 0-15ANNEX (ANX) 0-3 GROUND/ UNDERGROUND (G) 0/1FLOOR (FLR) 1-127 LINE EQUIPMENT NUMBER (LENS) MG U G LV ANNEX 0 : Main Building 1 : Annex 1 2 : Annex 2 3 : Annex 3 RSC Enter the RSC defined by the ARSC command. Since RSC = 0 is preserved for ATTCON, a station can use the RSC range from 1 to 15. SFC Enter the SFC defined by the ASFC command. Since SFC = 0 is preserved for ATTCON, a station can use the SFC range from 1 to 15 Imput Data 0-15 Note:When the D term is used for Guest station, ROOM CLASS is fixed to “15”. Room Class STN Enter the station number with regard to the following: The number of station number (STN) digits is designated by the ASYD command, SYS1, INDEX 16. Example:0 = Single Room 1 = Suite Room 1-4 : Not used 5 : DP (10 pps) 6 : PB 7 : DP/PB 8 : DP (20 pps) 9 : Not used 10 : House Phone 11 : Not used 12 : D term13-31 : Not Used
CHAPTER 4 NDA-24288 Page 242 Revision 1.0 AGST 4. Data Sheet TENANT NUMBER (TN)STATION NUMBER (STN) MAXIMUM 6 DIGITSLINE EQUIPMENT NUMBER (LENS)TELEPHONE EQUIPMENT CLASS (TEC) 1 – 31ROUTE RESTRICTION CLASS (RSC) 0 – 15SERVICE FEATURE CLASS (SFC) 0 – 15ROOM CLASS (ROOM CLASS) 0 – 15ANNEX (ANX) 0 – 3GROUND/ UNDER- GROUND (G) 0/1FLOOR (FLR) 1 – 127 MG U G LV
NDA-24288 CHAPTER 4 Page 243 Revision 1.0 AASN AASN: Assignment of Alternated Administration Station Number 1. General This command changes a currently assigned Administration Station Number. 2. Precautions 1. This command is used for the Hotel Application only. 2. Input a number which is not currently assigned. If a station number currently being used is to be assigned as a new number, delete the station first via the RAST command. 3. When the “PKG CHECK” message is displayed during assignment, confirm the LENS location of the circuit card (PA-16LC, etc.) accommodating the station, then press the ENTRY key. 4. When you have changed the station number, update the data sheet for the AAST command. 3. Data Entry Instructions OLD STN Enter the current station number to be changed. TN Enter the tenant number of the station.NEW STN Enter the new station number according to the numbering plan. Update the data sheet for the AAST command. TENANT NUMBER (TN) NEW STATION NUMBER (NEW STN) OLD STATION NUMBER (OLD STN)
CHAPTER 4 NDA-24288 Page 244 Revision 1.0 AACL AACL: Assignment of Administration Station Class 1. General This command changes the data assigned to an Administration Station: Telephone Equipment Class (TEC), Service Feature Class (SFC), Route Restriction Class (RSC), ROOM CLASS and Floor Service Data. 2. Precautions 1. This command is used for the Hotel Application only. 2. Only Telephone Equipment Classes (TECs) 1-4, 12-15, 18-20 and 13 may be assigned via this command. 3. Floor Service Data is displayed only in the case of the ASYD command, SYS1 INDEX 165, b7 = 1 (Floor Service is provided). 4. When you have changed the station class, update the data sheet for the AAST command.
NDA-24288 CHAPTER 4 Page 245 Revision 1.0 AACL 3. Data Entry Instructions TEC RSCANNEX G NOTE STN SFC TENANT NUMBER (TN) STATION NUMBER (STN) Max. 6 digitsTELEPHONE EQUIPMENT CLASS (TEC) 1-31 ROUTE RESTRICTION CLASS (RSC) 0-15SERVICE FEATURE CLASS (SFC) 0-15ROOM CLASS 0-15ANNEX (ANX) 0-3 GROUND/ UNDERGROUND (G) 0/1FLOOR (FLR) 1-127 112 1 1 1 : DP (10 pps) 2 : PB 3 : DP/PB 4 : DP (20 pps) 5-8 : Not Used 9 : House Phone 10-11 : Not Used 12 : Dterm 13 : Data Terminal via Dterm 14 : Hot Line 15 : CAS Line 16 : Data Terminal via Data Module 17 : Not Used 18 : Virtual Line Appearance (for D term Multi-Line) 19-22 : Not Used 23 : ISDN Terminal 24-25 : Not Used 26 : Not Used 27 : Eight Conference Equipment 28-31 : Not Used Enter the RSC defined by the ARSC/ASCR/ADNR command. Since RSC = 0 is preserved for ATTCON, a station can use the RSC range from 1 to 15.0 : Main Building 1 : Annex 1 2 : Annex 2 3 : Annex 3 0 : Ground 1 : Underground Enter the station number with regard to the following: The number of station number (STN) digits is designated by the ASYD command, SYS1, INDEX 16. Enter the SFC defined by the ASFC command. Since SFC = 0 is preserved for ATTCON, a station can use the SFC range from 1 to 15.When you have changed the station class, update the data sheet for the AAST command. 0 : General Administration (Ordinary Telephone, D term) 1-5 : Not Used 6 : Guest Service Telephone (Dterm and External Equipment) 7-14 : Not Used 15 : Guest Service Telephone (Dterm) ROOM CLASS
CHAPTER 4 NDA-24288 Page 246 Revision 1.0 AGSN AGSN: Assignment of Alternated Guest Station Number 1. General This command changes a currently assigned Guest Station Number. 2. Precautions 1. This command is used for the Hotel Application only. 2. Input a number which is not currently assigned. If a station number currently being used is to be assigned as a new number, delete the station first via the RGST command. 3. When the “PKG CHECK” message is displayed during assignment, confirm the LENS location of the circuit card (PA-16LC, etc.) accommodating the station, then press the ENTER key. 4. When you have changed the station number, update the data sheet for the AGST command. 3. Data Entry Instructions OLD STN Enter the current station number to be changed. NEW STN Enter the new station number according to the numbering plan. Update the data sheet for the AGST command. TENANT NUMBER (TN) NEW STATION NUMBER (NEW STN) OLD STATION NUMBER (OLD STN) TN Enter the tenant number of the station.
NDA-24288 CHAPTER 4 Page 247 Revision 1.0 AGCL AGCL: Assignment of Guest Station Class 1. General This command changes the data assigned to a Guest Station: Telephone Equipment Class (TEC), Service Feature Class (SFC), Route Restriction Class (RSC), ROOM CLASS and Floor Service Data [Annex (ANX), Ground/Underground (G), Floor (FLR)]. 2. Precautions 1. This command is used for the Hotel Application only. 2. Only Telephone Equipment Classes (TECs) 5-8, 10 and 12 may be assigned via this command. 3. Floor Service Data is displayed only in the case of the ASYD command, SYS1, INDEX 165, b7 = 1 (Floor Service is provided). 4. When you have changed the station class, update the data sheet for the AGST command.
CHAPTER 4 NDA-24288 Page 248 Revision 1.0 AGCL 3. Data Entry Instructions TEC RSCANNEX G NOTE STN SFC TENANT NUMBER (TN) STATION NUMBER (STN) Max. 6 digitsTELEPHONE EQUIPMENT CLASS (TEC) 1-31 ROUTE RESTRICTION CLASS (RSC) 0-15SERVICE FEATURE CLASS (SFC) 0-15ROOM CLASS 0-15ANNEX (ANX) 0-3 GROUND/ UNDERGROUND (G) 0/1FLOOR (FLR) 1-127 112 1 1 Enter the RSC defined by the ARSC/ASCR/ADNR command. Since RSC = 0 is preserved for ATTCON, a station can use the RSC range from 1 to 15.0 : Main Building 1 : Annex 1 2 : Annex 2 3 : Annex 3 0 : Ground 1 : Underground Enter the station number with regard to the following: The number of station number (STN) digits is designated by the ASYD command, SYS1, INDEX 16. Enter the SFC defined by the ASFC command. Since SFC = 0 is preserved for ATTCON, a station can use the SFC range from 1 to 15.When you have changed the station class, update the data sheet for the AAST command. ROOM CLASS 1-4 : Not Used 5 : DP (10 pps) 6 : PB 7 : DP/PB 8 : DP (20pps) 9 : Not Used 10 : House Phone 11 : Not Used 12 : Dterm 13 : Data Terminal via Dterm 14-31: Not Used 0-15 Note: When the D term is used for Guest station, ROOM CLASS is fixed to “15”.