NDA-24288 CHAPTER 4 Page 59 Revision 1.0 AHSY 101b 0LANG = 0 Incoming calls terminating to the Attendant Console from a guest station of the language category correspond to each bit. The key to which the call terminates: 0: GST1 Key 1: GST2 Key Language data is assigned to each guest station based on information from the PMS. b 1LANG = 1 b 2LANG = 2 b 3LANG = 3 b 4LANG = 4 b 5LANG = 5 b 6LANG = 6 b 7LANG = 7 102b 0LANG = 8 When an incoming call terminates to the Attendant Console from a guest station of the language category corresponding to each bit. The key to which the call terminates: 0: GST1 Key 1: GST2 Key Language data is assigned on each guest station basis as per the information from the PMS. b 1LANG = 9 b 2LANG = 10 b 3LANG = 11 b 4LANG = 12 b 5LANG = 13 b 6LANG = 14 b 7LANG = 15 103 Tenant Number of Paging Console (2~63/255 = 02~FF Hex) 104b 0 Miscellaneous Timer Counter (MTC) is to be assigned a value from 0 Hex to F Hex (0–15). Paging Console Auto- matic Recall Timer: Timer Value Setting is MTC × TC sec. Note:When this data is 00 Hex, ROM data is automatically set to 3 min. b1 b2 b3 b4Timer Class (TC) is to be assigned one of the fol- lowing values: b 6b5b4b6b5b4 000=–100=64 sec. 001=8 sec. 101= – 010=16 sec. 110=– 011=32 sec. 111=– b5 b6 b7 Paging Console Automatic Recall Timer value 0/1 = Ineffective/Effective INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT
CHAPTER 4 NDA-24288 Page 60 Revision 1.0 AHSY — AHSY INDEX 105 b7 — Display Pattern A: b 7 = 0 (For Interface Type Model 60/90/120) Display Pattern B: b 7 = 1 (For Interface Type Model 90/120) 1050 b 0Not used 0 b 1 b2 Maid Dial service from Attendant Console 0/1 = Not Required/Required 0 b 3 Office Name Display on Attendant Console assigned at AOFC command or ASYD command SYS 1, INDEX 96 through 115. 0/1 = In/Out of Service b 4 Pattern of Wake-Up Time Indication on the Attendant Console 0/1 = 24-Hour/12-Hour System 0 b 5Not used 0 b 6 b7 Guest Name Display on Attendant Console 0/1 = Interface Type Model 60, 90, 120/Model 90, 120 106 00 Not used INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT 567891011121314151617181920 1234 Guest Name Display Area (15 characters) SPACE SPACE SPACE Wake-Up Tim e (4 characters)Language (4 characters)Room Class (3 characters) Room Status (4 characters) Station Number (Max. 6 digits) 567891011121314151617181920 1234 Guest Name Display Area (16 characters) SPACE SPACE Station Number (Max. 6 digits)Wake-Up Time Option Data (8 characters)Room Status (3 characters)
NDA-24288 CHAPTER 4 Page 61 Revision 1.0 AHSY Display Pattern when “0” is assigned in b7 Note:b7 = 0: When PMS Model 60/90/120. b7 = 1: When PMS Model 90, 120. INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT 107 b0Display Pattern for termination b 1b0b1b0 00=Pattern 1 10 01=Pattern 2 11 Designation of Display Pattern of D term (Special Administration Station) for Guest Name Display D term service. b1 b2Display Pattern for call origination b 3b2b3b2 00 01=Pattern 5 11 10=Pattern 6b3 b4Display Pattern for answering a call, or the caller an- swers a call originated by Dterm. b 5b4 b5b4 00 01=Pattern 8 01 11=Pattern 9 b5 b6Tenant of Dterm that displays Guest Name 0/1 = All Tenants/Only Tenant No. 1 b7Guest Name Display on Dterm 1: Display pattern is determined as per the contents of b0 through b6 Option A and B 0: VIP and LANGNote = Pattern 3 = Pattern 4 = Pattern 7 ×× GUEST NAME (a) ×× GUEST NAME (b) ××× × × STATION NUMBER Guest Name is displayed first: (pattern (a)) and after a predetermined timing the pattern is automatically changed to pattern (b). ROOM STATUS
CHAPTER 4 NDA-24288 Page 62 Revision 1.0 AHSY INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT 108b 0Display Change Timer for the Display Pattern of the Answering station (assigned INDEX 107 b 4 and b5) 0 Hex: Standard Timer Value = 8 to 10 sec. 1 Hex ~ F Hex: Timer Value = (1–15) × 1 sec. b1 b2 b3 b4Display Change Timer for the Display Pattern of the Originating station (assigned INDEX 107 b 3 and b2) 0 Hex: Standard Timer Value = 2–4 sec. 1 Hex ~ F Hex: Timer Value = (1–15) × 1 sec. b5 b6 b7 1090 b 0Not used b 1 Charging Method of Attendant Console (If No. 7 CCIS service is provided, “1” must be assigned) 0 = 9 + Trunk Number 1 = Specific Attendant Number b 2 When Admin. or GST STA dials the unused number of the Dead level number 0/1 = –/ The call is transferred to the Hotel Console automatically b 3Not used b 4 Emergency Call Monitor 0/1 = Out/In Service b 5 Busy Status Display – Hotel Attendant Console 0/1 = Out/In Service b 6 Front Desk Terminal (FDT) function keys 0/1 = Fixed/Flexible 0 b 7Not used
NDA-24288 CHAPTER 4 Page 63 Revision 1.0 AHSY 110b 0 Room key Interface 0 : Interface is absent (STAY/OUT is displayed) 1 : Interface is present (Key status is displayed) b 1 Attendant Console Guest Information Service 0/1 = Not Required/Required 0 b 2Not used b 3 Called Number Display on the Attendant Console 0/1 = Out/In Service 0 b 4 Not used 0 b5 0 b6 b7 Guest Name Display – Dterm, Guest Information Display – Dterm/PMS Terminal Model 120 0/1 = Out/In Service 1110 b 0Fixed Data 0 b 1 b2 Restriction for hooking when an outgoing C.O. line call has originated from a suite room 0/1 = Restriction/No Restriction b 3 Setting of Message Registration Data to be sent out to the PMS b 4b3 0 0 : The pilot number is sent out for the Suite Room; the Main Room Station Number is sent out for the Connecting Room. 0 1 : The Station Number of each station within the room is sent out. b 4 0 b5Fixed Data 0 b 6 b7 Connecting Room 0/1 = Out/In Service INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT
CHAPTER 4 NDA-24288 Page 64 Revision 1.0 AHSY 112 00 b0 Not used b1 b2 b3 b4 b5 Wake-Up - Head Start Operation 0/1 = Out/In Service b6Not usedb7 113 00 Not used 1140 b0 Not used 0 b1 0b2 0b3 0b4 b5 Hotel Console key designation 0/1 = Depending on SYS-1, INDEX 160, Bits 3 and 4 (ASYD)/PI 115-126 (AHSY) 0 b6Not used b7 Consecutive Dialing from Attendant Console (for service such as VMM) 0/1 = Not Required/Required If “1” (Required) is assigned, switch settings for the ATI card are necessary. INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT
NDA-24288 CHAPTER 4 Page 65 Revision 1.0 AHSY 115 Attendant Console Key Data 116 117 118 119 120 121 122 123 124 125 126 127 00 Not used 128 00 Not used 129 00 Not used 130 00 Not used 131 00 Not used 132 00 Not used 133 00 Not used 134 00 Not used 135 00 Not used 136 00 Not used 137 00 Not used 138 00 Not used INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT 121 122 123 124 125 126789 111210 115 116 117 118 119 120123 564 INDEX INDEXOperation Key Operation Key ENT CE END 81H— —WU SET 91H— —CHECK IN 82H— —WU RESET 92H— —CHECKOUT 83H— —MW SET 93H— —— — 84H— —MW RESET 94H— —— — 85H— —DD SET 95H— —C.O. CHANGE 86H— —DD RESET 96H— —BOSS/SEC ENT 87H— —RC SET 97H— —BOSS/SEC RESET 88H— —RC RESET 98H— —— — 89H— —STATUS 99H— —— — 8AH— —AUDIT 9AH— —— — 8BH— —— —9BH— —— — 8CH— —— —9CH— —— — 8DH— —— —9DH— —— — 8EH— —— —9EH— —— — 8FH— —— —9FH— —GRP DND RESET 90H— —— —A0H— —GRP RESTRICTION SET A1H— —GRP RESTRICTION RESET
CHAPTER 4 NDA-24288 Page 66 Revision 1.0 AHSY 1390 b0Not used 0b1 b2 MW Lamp Indication of “Do Not Disturb” 0/1 = Lights Steadily/Flashes b3 MW Lamp Indication of “Do Not Disturb” 0/1 - Not Required/Required b4 MW Lamp Indication of “Message Waiting” 0/1 = Lights Steadily/Flashes b5 MW Lamp Indication of “Message Waiting” 0/1 = Not Required/Required b6 2-Line Guest Name Display on a Dterm 0/1 = Out/In Service 0 b7Not used 140 00 Not used 141 00 Not used 142 00 b0 b1 b2 b3 b4Wa k e - U p C a l l “Busy” Condition: Transfer to Attendant b5Wa k e - U p C a l l “Don’t Answer” Condition: Transfer to Attendant b6Wa k e - U p C a l l “Block” Condition: Transfer to Attendant b7Wa k e - U p C a l l “Busy/Block” Condition: Transfer to Attendant 143 00 Not used 144 00 Not used 145 00 Not used 146 00 Not used 147 00 Not used 148 00 149b0 Hotel service in CCIS No. 7 0/1 = Out/In Service b1~b7Not used INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT
NDA-24288 CHAPTER 4 Page 67 Revision 1.0 AHSY 150 b0b2b1b0b2b1b0 000=–100=Model 120 001= –101=– 010=Model 60 110=– 011=Model 90 111=– b1 b2 0b3~b7Not used 151 00 Not used 152 00 153 00 154 00 155 00 156 00 157 00 158 00 159 00 160 00 161 00 162 00 163 b0 2nd Wake-Up Call Service 0/1 = Out/In Service b1 2nd Wake-Up Call Timer Indication on Hotel Console 0/1 = Out/In Service b2 2nd Wake-Up Call Cancel while Hotel Console is connected to the target station 0/1 = Out/In Service b3Not used b4The number of calls for Automatic Wake-Up at the same time (per LP) b5b4b5b4 00=512 Calls 10=128 Calls 01= 64 Calls 11=256 Callsb5 b6The number or Retry when a Wake-Up Call encounters busy status. b7b6b7b6 00=3 times 10=Once 01=Twice 11=No Retryb7 164 00Not used INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT
CHAPTER 4 NDA-24288 Page 68 Revision 1.0 AHSY 165 b0EQP Type for Maid Status (0~15) 0: EQP16 1~F: EQP1~EQP15b1 b2 b3 b4 Tone Type when Maid Status “To be cleaned” has been set: 0/1 = Tone designated in ASYD (SYS-1 INDEX 163, b5, b6)/SST b5 Tone Type when Maid Status “Cleaned” has been set: 0/1 = Tone designated in ASYD (SYS-1 INDEX 163, b5, b6)/SST b6 Tone Type when Maid Status “Ready for Occupancy” has been set: 0/1 = Tone designated in ASYD (SYS-1 INDEX 163, b5, b6)/SST 0b7Not used 166 b0TN = 2 Whether “C.O. Incoming Call Answer Station Manual Change” service is provided or not is set on the basis of each TN (Tenant) corresponding to each bit. 0/1 = Out/In Service b1TN = 3 b2TN = 4 b3TN = 5 b4TN = 6 b5TN = 7 0 b6Not used 0b7 167 00Not used 168 00 Not used 169 00 Not used 170 00 Not used 171 00 Not used 172 00 Not used 173 00 Not used 174 00 Not used 175 00 Not used 176 00 Not used 177 00 Not used 178 00 Not used INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT