NEC Neax 2000 Ivs2 Wcs System Manual
Have a look at the manual NEC Neax 2000 Ivs2 Wcs System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 73 DESCRIPTION DATA Assign the access code of paging groups for Group Call-Automatic Conference (6/ 10-Par ty). NOTE:Even if an extension does not belong to the conference group, the extension can page the conference group, and can re- participate in the conference if thereisanidlecircuitonthe Conference Trunk. (1) (2)Y=0-3 (Tenant Group No.) X-XXXX: Access Code A200 : Simultaneous Paging Group 0 for 6/10 Party A207 : Simultaneous Paging Group 7 for 6/10 Party A210 : Re-par ticipation Group 0 for 6 /1 0 Par ty A217 : Re-par ticipation Group 7 for 6 /1 0 Par ty AssignaGroupCall-Automatic Conference (6/10-Par ty) key of each paging group to the D ter m, if required. NOTE:Even if an extension does not belong to the conference group, the extension can page the conference group, and can re- participate in the conference if thereisanidlecircuitonthe Conference Trunk. (1) (2)YY=00 X-XXXXXXXX: My Line No. + + Key No. F0B00: Simultaneous Paging Group 0 fo r 6/10 Par ty F0B07: Simultaneous Paging Group 7 fo r 6/10 Par ty F0B10: Re-participation Group 0 fo r 6/10 Par ty F0B17: Re-participation Group 7 fo r 6/10 Par ty Specify the duration of simultaneous paging. (1) (2)Y=0 95 01-99: 4-396 sec. in 4 sec. increments If no data is set, the default setting is 32-36 seconds. CM41 END CM90 A CM20 ~ ~ ~ ~ , ~ ~ ~ ~
NEAX2000 IVS2WCS System Manual (PCS)Page 74ND-70920 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming Group Call-2 Way Calling Refer to the WCS Features and Specifications. DESCRIPTION DATA Assign the stations which belongs to each paging group, and their number within the group. A maximum of nine stations can be paged simultaneously except the confer- ence leader. NOTE 1:Single line telephones, D terms and PSs can be assigned as the station within the group. A vir tual-line cannot be as- signed. NOTE 2:A station can belong to plural group. (1) (2)YY=00-07: Simultaneous Paging Group 0-7 00-15: Serial No. within the Group X-XXXXXXXX:Station No. Assign a Service Restriction Class to each station. (1) (2)YY=02 X-XXXXXXXX: Station No. XX YY XX: Service Restriction Class A (00-15 ) Allow the Service Restriction Class A to page the conference. (1) (2)YYY=119 00-15: Service Restriction Class A assigned by CM12 YY=02 0:Allowed Assign the access code of paging groups for Group Call-2 Way Calling. NOTE:Even if an extension does not belong to the conference group, the extension can page the conference group. (1) (2)Y=0-3 (Tenant Group No.) X-XXXX: Access Code A220 : Simultaneous Paging Group 0 for Group Call-2 Way Calling A227 : Simultaneous Paging Group 7 for Group Call-2 Way Calling Assign a Group Call-2 Way Calling key of each paging group to the D term, if required. NOTE:Even if an extension does not belong to the conference group, the extension can page the conference group. (1) (2)YY=00 X-XXXXXXXX: My Line No. + + Key No. F0B20: Simultaneous Paging Group 0 for Group Call-2 Way Calling F0B27: Simultaneous Paging Group 7 for Group Call-2 Way Calling START CM56 CM15 CM12 CM20 CM90 END ~ ~ , ~ ~
CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 75 Multi-Line Operation-PS Refer to the WCS Features and Specifications. DESCRIPTION DATA Assign a PS station number to the vi rtual PS number. (1) (2)000-255: Virtual PS LEN X-XXXXXXXX: Primary PS station No. X-XXXXXXXX: Sub-line PS station No. Assignthesub-linePSnumbertoeach primary PS station, both are assigned by CM1C. (1) (2)YY=01 X-XXXXXXXX: Primary PS station No. X-XXXXXXXX: Sub-line PS station No. Assign PS-ID of the sub-line PS as “NONE”. (1) (2)YY=21 X-XXXXXXXX: Sub-line PS station No. assinged by CM1C NONE Specify the terminal kind of the PS as “D termPS II”. This data must be set to both the primary PS station number and the sub-line PS station number assigned by CM1C. (1) (2)YY=15 X-XXXXXXXX: Primary PS station No. Sub-line PS station No. 00 : D termPS II Provide the multi-line function to the virtual PS No. for the sub-line PS. (1) (2)YY=05 X-XXXXXXXX: Virtual PS No. 0 : Provided (Sub-line station) Assign the virtual line/trunk data for the sub line PS as same as the primary PS. SeeVir tual Line/Trunk Data Programming (For Integrated/Adjunct CCIS) on Page 56andTrunk Data Programming (For Adjunct Analog) on Page 59 CM5A START CM1C A CM1D CM12 CM10 CM30 CM35
NEAX2000 IVS2WCS System Manual (PCS)Page 76ND-70920 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming To assign the PS station to the line key on the Dterm, assign the following data. DESCRIPTION DATA Assign a vir tual PS station number to the key number of the D term. A vir tual PS number of PS sub-line can be assigned to the key on the D term. (1) (2)YY=00 Primary Extension No. + + Key No. X-XXXXXXXX: Virtual PS Station No. END A CM90 ,
CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 77 Number Sharing Refer to the WCS Features and Specifications. DESCRIPTION DATA Specify the combination of the main station and the sub station, also the contrary combination, as follows. 1st data : Main station (D ter mMy Line) 2nd data: Sub station (PS) 1st data : Sub station (PS) 2nd data: Main station (D ter mMy Line) NOTE:As the main station number, D term My Line number must be assigned. As the sub station number, following number must be assigned. Integrated type/Adjunct type (CCIS): Virtual PS number assigned by CM10. Adjunct type (Analog): PS station number assigned by CM30 YY=04. (1) (2)YY=19 (Assignment of main station and sub station) X-XXXXXXXX: Main station (D termMy Line) No./Sub station (PS) No. X-XXXXXXXX: Sub station (PS) No./ Main station (D termMy Line) No. Assign the Class of Service to required sta- tions. NOTE:For the Trunk Restriction Class (CM12 YY=01) and the Tenant Number (CM12 YY=04), the same data must be assigned to the sub station and the main station. (1) (2)YY=02 X-XXXXXXXX (Station No.) XX YY XX: Service Restriction Class A (00-15) To the sub station (PS), specify the number which is informed to calling/called party, SMDRandMCIasthemainstation number. (1) (2)YYY=127 00-15: Service Restriction Class A of main station 1 : Own station number is informed (1) (2)00-15: Service Restriction Class A of sub station 0 : Main station number is informed CM15 START CM12 A
NEAX2000 IVS2WCS System Manual (PCS)Page 78ND-70920 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming DESCRIPTION DATA Provide the capability of setting/cancelling theNumberSharingfromthesubstation. (1) (2)YYY=128 00-15: Service Restriction Class A of main station 1:Notprovide (1) (2)00-15: Service Restriction Class A of sub station 0:Toprovide Specify whether the sub station is controlled as same as the main station, by a Message Waiting lamp control signal sent from the MCI. NOTE:This assignment is effective only when the system is an Integrated type. Do not assign CM15 YYY=129 for a sub station. (1) (2)YYY=129 00-15 : Service Restriction Class A of main station 0 : Main station and sub station are controlled. 1 : Only main station is controlled. Provide the Number Sharing set/cancel keys to the main station (D ter m). (1) (2)YY=00 My Line No. + + Key No. F0A94: Number Sharing Set/Cancel Assign the Access Code for setting or canceling Number Sharing from the sub station (PS). (1) (2)Y=0-3 (Tenant Group Number) X-XXXX: Access Code A192 : Set Number Sharing from the sub station A193 : Cancel Number Sharing from the sub station END CM15 A CM20 CM90,
CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 79 Voice Mail Indication Refer to the WCS Features and Specifications. DESCRIPTION DATA Provide PS stations with Message Waiting service. The first data should be the virtual PS number. (1) (2)YY=03 X-XXXXXXXX: Virtual PS No. 0:Provided (For the station with MW lamp)START CM13 END
NEAX2000 IVS2WCS System Manual (PCS)Page 80ND-70920 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Multi-Site Roaming Programming MULTI-SITE ROAMING PROGRAMMING According to the following procedure, assign the system data for Roaming service. PREPARATION CONFIRMING NETWORK NUMBERING PLAN (OPEN NUMBERING SYSTEM/ CLOSED NUMBERING SYSTEM) START NETWORK NUMBERING PLAN PROGRAMMING (OPEN NUMBERING SYSTEM/ CLOSED NUMBERING SYSTEM) Q931a DIGITAL TRUNK DATA PROGRAMMING (FOR HOME PBX AND VISITOR PBX) ROAMING PS DATA PROGRAMMING (FOR HOME PBX AND VISITOR PBX) HOME PS DATA PROGRAMMING (FOR HOME PBX) VISITOR PS DATA PROGRAMMING (FOR VISITOR PBX) END Page 81 Page 82 Page 85 Page 85 Page 91 Page 93
CHAPTER 3 SYSTEM DATA PROGRAMMING Multi-Site Roaming Programming NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 81 Confirming Network Numbering Plan Confirm whether the network adopts Open Numbering System or Closed Numbering System for the network numbering plan. NOTE:The System data stored in the memory of the DBM (PN-AP00-A) card can be saved, loaded, and verified from the MAT. To save; Memory Area No. : A, Memory Address: 00900-10870 To load or verify; File Extension : DMA
NEAX2000 IVS2WCS System Manual (PCS)Page 82ND-70920 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Multi-Site Roaming Programming Network Numbering Plan Programming DESCRIPTION DATA Assign an access code for LCR Group 0-3. For Closed Numbering System, assign the second data to A129 (LCR Group 3). (1) (2)Y=0-3 (Numbering Group 0-3) X-XXXX: Access Code A126: LCR Group 0 A127: LCR Group 1 A128: LCR Group 2 A129: LCR Group 3 Specify the number of digits and the first digit for station number. (1) (2)Y=0-3 (Numbering Group 0-3) X: First Digit of Station No. 801: 1 digit 802: 2 digits 803: 3 digits 804: 4 digits 805: 5 digits Assign an Area Code Development Pattern number. to each LCR Group. For Closed Numbering System, assign the firstdatato3. (1) (2)YYYY=A000 0-3: LCR Group 0-3 4000-4007: Area Code Development Pa tt er n N o. 0 -7 Assign a Route Pattern number. to each area code for the Area Code Development Pattern number. assigned by CM8A YYYY=A000. (1) (2)YYYY=4000-4007 (Area Code Devel- opment Pattern No. 0-7) XX...XX (Area Code, Max. 8 digits) 0000-0255: Route Pattern No. Assign an area code including LCR access code assigned by CM20>A129. (1) (2)YYYY=4000-4007 (Area Code Devel- opment Pattern No. 0-7) X-XXXXXXXX (Area Code, 8 digits) 8000 (Intra-Office Termination) 8001 (1-digit intra-office station) 8002 (2-digit intra-office station) 8003 (3-digit intra-office station) 8004 (4-digit intra-office station) 8005 (5-digit intra-office station) 8006 (6-digit intra-office station) 8007 (7-digit intra-office station) 8008 (8-digit intra-office station)START CM20 CM8A A