    DESCRIPTION DATA
    Assign the access code of paging groups
    for Group Call-Automatic Conference (6/
    10-Par ty).
    NOTE:Even if an extension does not
    belong to the conference group,
    the extension can page the
    conference group, and can re-
    participate in the conference if
    thereisanidlecircuitonthe
    Conference Trunk.
    (1)
    (2)Y=0-3 (Tenant Group No.)
    X-XXXX: Access Code
    A200 : Simultaneous Paging Group
    0 for 6/10 Party
    A207 : Simultaneous Paging Group
    7 for 6/10 Party
    A210 : Re-par ticipation Group 0
    for 6 /1 0 Par ty
    A217 : Re-par ticipation Group 7
    for 6 /1 0 Par ty
    AssignaGroupCall-Automatic
    Conference (6/10-Par ty) key of each
    paging group to the D
    ter m, if required.
    NOTE:Even if an extension does not
    belong to the conference group,
    the extension can page the
    conference group, and can re-
    participate in the conference if
    thereisanidlecircuitonthe
    Conference Trunk.
    (1)
    (2)YY=00
    X-XXXXXXXX: My Line No. + + Key
    No.
    F0B00: Simultaneous Paging Group 0
    fo r 6/10 Par ty
    F0B07: Simultaneous Paging Group 7
    fo r 6/10 Par ty
    F0B10: Re-participation Group 0
    fo r 6/10 Par ty
    F0B17: Re-participation Group 7
    fo r 6/10 Par ty
    Specify the duration of simultaneous
    paging.
    (1)
    (2)Y=0
    95
    01-99: 4-396 sec. in 4 sec. increments
    If no data is set, the default setting is 32-36
    seconds.
    CM41
    END
    CM90
    A
    CM20
    ~ ~
    ~ ~
    ,
    ~ ~
    ~ ~ 
    						
    							NEAX2000 IVS2WCS System Manual (PCS)Page 74ND-70920 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    WCS Feature Programming
    Group Call-2 Way Calling
    Refer to the WCS Features and Specifications.
    DESCRIPTION DATA
    Assign the stations which belongs to each
    paging group, and their number within the
    group. A maximum of nine stations can be
    paged simultaneously except the confer-
    ence leader.
    NOTE 1:Single line telephones, D
    terms
    and PSs can be assigned as the
    station within the group.
    A vir tual-line cannot be as-
    signed.
    NOTE 2:A station can belong to plural
    group.
    (1)
    (2)YY=00-07: Simultaneous Paging Group
    0-7
    00-15: Serial No. within the Group
    X-XXXXXXXX:Station No.
    Assign a Service Restriction Class to each
    station.
    (1)
    (2)YY=02
    X-XXXXXXXX: Station No.
    XX YY
    XX: Service Restriction Class A
    (00-15 )
    Allow the Service Restriction Class A to
    page the conference.
    (1)
    (2)YYY=119
    00-15: Service Restriction Class A
    assigned by CM12 YY=02
    0:Allowed
    Assign the access code of paging groups
    for Group Call-2 Way Calling.
    NOTE:Even if an extension does not
    belong to the conference group,
    the extension can page the
    conference group.
    (1)
    (2)Y=0-3 (Tenant Group No.)
    X-XXXX: Access Code
    A220 : Simultaneous Paging Group 0
    for Group Call-2 Way Calling
    A227 : Simultaneous Paging Group 7
    for Group Call-2 Way Calling
    Assign a Group Call-2 Way Calling key of
    each paging group to the D
    term, if required.
    NOTE:Even if an extension does not
    belong to the conference group,
    the extension can page the
    conference group.
    (1)
    (2)YY=00
    X-XXXXXXXX: My Line No. + + Key
    No.
    F0B20: Simultaneous Paging Group 0
    for Group Call-2 Way Calling
    F0B27: Simultaneous Paging Group 7
    for Group Call-2 Way Calling
    START
    CM56
    CM15
    CM12
    CM20
    CM90
    END
    ~ ~
    ,
    ~ ~ 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    WCS Feature Programming
    NEAX2000 IVS2WCSSystemManual(PCS)
    ND-70920 (E), Issue 1.0Page 75
    Multi-Line Operation-PS
    Refer to the WCS Features and Specifications.
    DESCRIPTION DATA
    Assign a PS station number to the vi rtual
    PS number.
    (1)
    (2)000-255: Virtual PS LEN
    X-XXXXXXXX: Primary PS station No.
    X-XXXXXXXX: Sub-line PS station No.
    Assignthesub-linePSnumbertoeach
    primary PS station, both are assigned by
    CM1C.
    (1)
    (2)YY=01
    X-XXXXXXXX: Primary PS station No.
    X-XXXXXXXX: Sub-line PS station No.
    Assign PS-ID of the sub-line PS as
    “NONE”.
    (1)
    (2)YY=21
    X-XXXXXXXX: Sub-line PS station No.
    assinged by CM1C
    NONE
    Specify the terminal kind of the PS as
    “D
    termPS II”.
    This data must be set to both the primary
    PS station number and the sub-line PS
    station number assigned by CM1C.
    (1)
    (2)YY=15
    X-XXXXXXXX: Primary PS station No.
    Sub-line PS station No.
    00 : D
    termPS II
    Provide the multi-line function to the virtual
    PS No. for the sub-line PS.
    (1)
    (2)YY=05
    X-XXXXXXXX: Virtual PS No.
    0 : Provided (Sub-line station)
    Assign the virtual line/trunk data for the
    sub line PS as same as the primary PS.
    SeeVir tual Line/Trunk Data
    Programming (For Integrated/Adjunct
    CCIS) on Page 56andTrunk Data
    Programming (For Adjunct Analog) on
    Page 59
    CM5A START
    CM1C
    A
    CM1D
    CM12
    CM10
    CM30
    CM35 
    						
    							NEAX2000 IVS2WCS System Manual (PCS)Page 76ND-70920 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    WCS Feature Programming
    To assign the PS station to the line key on the Dterm, assign the following data.
    DESCRIPTION DATA
    Assign a vir tual PS station number to the
    key number of the D
    term.
    A vir tual PS number of PS sub-line can be
    assigned to the key on the D
    term.
    (1)
    (2)YY=00
    Primary Extension No. + + Key No.
    X-XXXXXXXX: Virtual PS Station No.
    END
    A
    CM90
    , 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    WCS Feature Programming
    NEAX2000 IVS2WCSSystemManual(PCS)
    ND-70920 (E), Issue 1.0Page 77
    Number Sharing
    Refer to the WCS Features and Specifications.
    DESCRIPTION DATA
    Specify the combination of the main station
    and the sub station, also the contrary
    combination, as follows.
    1st data : Main station (D
    ter mMy Line)
    2nd data: Sub station (PS)
    1st data : Sub station (PS)
    2nd data: Main station (D
    ter mMy Line)
    NOTE:As the main station number, D
    term
    My Line number must be
    assigned.
    As the sub station number,
    following number must be
    assigned.
    Integrated type/Adjunct type
    (CCIS):
    Virtual PS number assigned by
    CM10.
    Adjunct type (Analog):
    PS station number assigned by
    CM30 YY=04.
    (1)
    (2)YY=19 (Assignment of main station
    and sub station)
    X-XXXXXXXX: Main station (D
    termMy
    Line) No./Sub station
    (PS) No.
    X-XXXXXXXX: Sub station (PS) No./
    Main station (D
    termMy
    Line) No.
    Assign the Class of Service to required sta-
    tions.
    NOTE:For the Trunk Restriction Class
    (CM12 YY=01) and the Tenant
    Number (CM12 YY=04), the same
    data must be assigned to the sub
    station and the main station.
    (1)
    (2)YY=02
    X-XXXXXXXX (Station No.)
    XX YY
    XX: Service Restriction Class A (00-15)
    To the sub station (PS), specify the number
    which is informed to calling/called party,
    SMDRandMCIasthemainstation
    number.
    (1)
    (2)YYY=127
    00-15: Service Restriction Class A of
    main station
    1 : Own station number is informed
    (1)
    (2)00-15: Service Restriction Class A of
    sub station
    0 : Main station number is informed
    CM15 START
    CM12
    A 
    						
    							NEAX2000 IVS2WCS System Manual (PCS)Page 78ND-70920 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    WCS Feature Programming
    DESCRIPTION DATA
    Provide the capability of setting/cancelling
    theNumberSharingfromthesubstation.
    (1)
    (2)YYY=128
    00-15: Service Restriction Class A of
    main station
    1:Notprovide
    (1)
    (2)00-15: Service Restriction Class A of
    sub station
    0:Toprovide
    Specify whether the sub station is
    controlled as same as the main station, by
    a Message Waiting lamp control signal
    sent from the MCI.
    NOTE:This assignment is effective only
    when the system is an Integrated
    type.
    Do not assign CM15 YYY=129
    for a sub station.
    (1)
    (2)YYY=129
    00-15 : Service Restriction Class A of
    main station
    0 : Main station and sub station are
    controlled.
    1 : Only main station is controlled.
    Provide the Number Sharing set/cancel
    keys to the main station (D
    ter m).
    (1)
    (2)YY=00
    My Line No. + + Key No.
    F0A94: Number Sharing Set/Cancel
    Assign the Access Code for setting or
    canceling Number Sharing from the sub
    station (PS).
    (1)
    (2)Y=0-3 (Tenant Group Number)
    X-XXXX: Access Code
    A192 : Set Number Sharing from the
    sub station
    A193 : Cancel Number Sharing from
    the sub station
    END
    CM15
    A
    CM20
    CM90, 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    WCS Feature Programming
    NEAX2000 IVS2WCSSystemManual(PCS)
    ND-70920 (E), Issue 1.0Page 79
    Voice Mail Indication
    Refer to the WCS Features and Specifications.
    DESCRIPTION DATA
    Provide PS stations with Message Waiting
    service.
    The first data should be the virtual PS
    number.
    (1)
    (2)YY=03
    X-XXXXXXXX: Virtual PS No.
    0:Provided
    (For the station with MW lamp)START
    CM13
    END 
    						
    							NEAX2000 IVS2WCS System Manual (PCS)Page 80ND-70920 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Multi-Site Roaming Programming
    MULTI-SITE ROAMING PROGRAMMING
    According to the following procedure, assign the system data for Roaming service.
    PREPARATION
    CONFIRMING NETWORK NUMBERING PLAN
    (OPEN NUMBERING SYSTEM/
    CLOSED NUMBERING SYSTEM)
    START
    NETWORK NUMBERING PLAN PROGRAMMING
    (OPEN NUMBERING SYSTEM/
    CLOSED NUMBERING SYSTEM)
    Q931a DIGITAL TRUNK DATA PROGRAMMING
    (FOR HOME PBX AND VISITOR PBX)
    ROAMING PS DATA PROGRAMMING
    (FOR HOME PBX AND VISITOR PBX)
    HOME PS DATA PROGRAMMING
    (FOR HOME PBX)
    VISITOR PS DATA PROGRAMMING
    (FOR VISITOR PBX)
    END
    Page 81
    Page 82
    Page 85
    Page 85
    Page 91
    Page 93 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Multi-Site Roaming Programming
    NEAX2000 IVS2WCSSystemManual(PCS)
    ND-70920 (E), Issue 1.0Page 81
    Confirming Network Numbering Plan
    Confirm whether the network adopts Open Numbering System or Closed Numbering System for
    the network numbering plan.
    NOTE:The System data stored in the memory of the DBM (PN-AP00-A) card can be saved,
    loaded, and verified from the MAT.
    To save; Memory Area No. : A, Memory Address: 00900-10870
    To load or verify; File Extension : DMA 
    						
    							NEAX2000 IVS2WCS System Manual (PCS)Page 82ND-70920 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Multi-Site Roaming Programming
    Network Numbering Plan Programming
    DESCRIPTION DATA
    Assign an access code for LCR Group 0-3.
    For Closed Numbering System, assign the
    second data to A129 (LCR Group 3).
    (1)
    (2)Y=0-3 (Numbering Group 0-3)
    X-XXXX: Access Code
    A126: LCR Group 0
    A127: LCR Group 1
    A128: LCR Group 2
    A129: LCR Group 3
    Specify the number of digits and the first
    digit for station number.
    (1)
    (2)Y=0-3 (Numbering Group 0-3)
    X: First Digit of Station No.
    801: 1 digit
    802: 2 digits
    803: 3 digits
    804: 4 digits
    805: 5 digits
    Assign an Area Code Development
    Pattern number. to each LCR Group.
    For Closed Numbering System, assign the
    firstdatato3.
    (1)
    (2)YYYY=A000
    0-3: LCR Group 0-3
    4000-4007: Area Code Development
    Pa tt er n N o. 0 -7
    Assign a Route Pattern number. to each
    area code for the Area Code Development
    Pattern number. assigned by CM8A
    YYYY=A000.
    (1)
    (2)YYYY=4000-4007 (Area Code Devel-
    opment Pattern No. 0-7)
    XX...XX (Area Code, Max. 8 digits)
    0000-0255: Route Pattern No.
    Assign an area code including LCR
    access code assigned by CM20>A129.
    (1)
    (2)YYYY=4000-4007 (Area Code Devel-
    opment Pattern No. 0-7)
    X-XXXXXXXX (Area Code, 8 digits)
    8000 (Intra-Office Termination)
    8001 (1-digit intra-office station)
    8002 (2-digit intra-office station)
    8003 (3-digit intra-office station)
    8004 (4-digit intra-office station)
    8005 (5-digit intra-office station)
    8006 (6-digit intra-office station)
    8007 (7-digit intra-office station)
    8008 (8-digit intra-office station)START
    CM20
    CM8A
    A 
    						