    							CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-AP00-A (DBM)
    NEAX2000 IVS2WCSSystemManual(PCS)
    ND-70920 (E), Issue 1.0Page 123
    The figure in the SWITCH NAME column and the position in in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and , the setting of the switch varies with the system concerned.
    NOTE 1:Set the groove on the switch to the desired position.
    NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/
    unplugging the circuit card.
    SWITCH NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SW1
    (Piano Key SW)1For normal operation
    OFF Not used
    2For normal operation
    OFF Not used
    3For normal operation
    OFF Not used
    4 Not used
    SW0 (DIP SW)
    1-8 Not used
    J16
    For normal operation
    (Memory backup ON)
    LEFTNot used
    (Memory backup OFF)
    4
    3
    2
    1 OFF
    ON
    ON
    ON
    ON
    OFF
    12345678ONOFF
    Fro nt (Jumper pin)
    RIGHT 
    						
    							NEAX2000 IVS2WCS System Manual (PCS)Page 124ND-70920 (E), Issue 1.0
    CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-24DTA-C (DTI)
    PN-24DTA-C (DTI)
    Locations of Lamps, Switches, and Connectors
    SENSE
    RU N
    MB
    CRC
    PCM
    FRM
    RMT
    AIS
    BL SW1
    SW0
    JRR1
    AISS MAS
    JPR0
    JPS 
    						
    							CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-24DTA-C (DTI)
    NEAX2000 IVS2WCSSystemManual(PCS)
    ND-70920 (E), Issue 1.0Page 125
    Lamp Indications
    LAMP
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally.
    CRC Red Remains lit when detecting Cyclic Redundancy Checking (CRC)
    errors.
    PCM Red Remains lit when detecting PCM signal loss.
    FRM Red Remains lit when detecting Frame Alignment signal loss.
    RMT Red Remains lit when receiving Frame Alignment signal loss alarm
    from a distant office.
    AIS Red Remains lit when a pattern of consecutive “1” is received. THe
    distant office transmits this signal for a loop-back test.
    BL Red B channel status
    ON : More than 10 channels are busy
    OFF : All channels are idle
    Flash (60 IPM) : Only one channel is busy
    Flash (120 IPM) : 2 through 10 channels are busy 
    						
    							NEAX2000 IVS2WCS System Manual (PCS)Page 126ND-70920 (E), Issue 1.0
    CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-24DTA-C (DTI)
    Switch Settings
    SWITCH NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SENSE
    (Rotary SW)
    NOTE 10-3 Not used
    4-F Set the switch to match the AP Number (04-31) to
    be set by CM05.
    MB (Toggle SW)
    NOTE 2
    UP For make-busy
    For normal operation
    (Continued)
    F
    4
    AP No.SW1-4: ON
    04 05 06 07 08 09 10 11 12 13 14 15
    SW1-4: OFF
    20 21 22 23 24 25 26 27 28 29 30 31
    SW No.
    456789ABCDEF
    ON
    DOWN 
    						
    							CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-24DTA-C (DTI)
    NEAX2000 IVS2WCSSystemManual(PCS)
    ND-70920 (E), Issue 1.0Page 127
    SW0
    (Piano Key SW)
    1
    NOTE 3
    NOTE 4ONSource clock signal from network is
    sent to the PLO 0 input on MP card.
    OFFSource clock signal from network is
    not sent to the PLO 0 input on MP
    card.
    2
    NOTE 3
    NOTE 4ONSource clock signal from network is
    sent to the PLO 1 input on MP card.
    OFFSource clock signal from network is
    not sent to the PLO 1 input on MP
    card.
    3ONRemote loop-back
    For normal operation
    4ONLocal loop-back (AIS send)
    For normal operation
    5Set equalizer according to the cable
    length between the PBX and the
    MDF. OFF
    6
    OFF
    7
    OFF
    8 Not used
    (Continued)
    SWITCH NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    OFF
    ON
    5 6 7 8
    1 2 3 4
    OFF
    OFF
    ON
    OFF
    80-120 m (262.5-394 ft.)
    SW0-5 SW0-6 SW0-7CABLE LENGTH
    ON ON0-40 m (0-131.2 ft.)
    40-80 m (131.2-262.5 ft.)
    120-160 m (394-525 ft.)
    160-200 m (525-656 ft.)
    Signal is not sent ON ON ON
    ON ON OFF
    OFF ON OFF
    ON OFF ON
    OFF OFF OFF
    ON
    ON
    OFF 
    						
    							NEAX2000 IVS2WCS System Manual (PCS)Page 128ND-70920 (E), Issue 1.0
    CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-24DTA-C (DTI)
    SWITCH NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SW1
    (Piano Key SW)
    NOTE 41 Not used
    2 Not used
    3 Not used
    4ON AP No. 04-15
    OFF AP No. 20-31
    JPR0 (Jumper Pin)
    UPNeutral grounding on the receiving
    line is provided.
    Neutral grounding on the receiving
    line is not provided.
    JPR1 (Jumper Pin)
    Line impedance: 100 ohms
    Left Line impedance: 110 ohms
    JPS (Jumper Pin)
    UPNeutral grounding on the
    transmitting line is provided.
    Neutral grounding on the
    transmitting line is not provided.
    MAS (Jumper Pin)
    UP Clock Source
    Clock Receiver
    AISS (Jumper Pin)
    AIS signal is sent out when make-
    busy or power on.
    DOWNAIS signal is not sent out when
    make-busy or power on.
    (Continued)
    4
    3
    2
    1 OFF
    ON
    OFF
    OFF
    OFF
    DOWN
    Right
    DOWN
    DOWN
    UP 
    						
    							CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-24DTA-C (DTI)
    NEAX2000 IVS2WCSSystemManual(PCS)
    ND-70920 (E), Issue 1.0Page 129
    The figure in the SWITCH NAME column and the position in in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and , the setting of the switch varies with the system concerned.
    NOTE 1:Set the groove on the switch to the desired position.
    NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/
    unplugging the circuit card.
    NOTE 3:Set SW0-1 and SW0-2 as follows:
    NOTE 4:When the PBX is a clock source office, set the SW0-1 and SW0-2 on all the DTI cards
    mountedinPIM0toOFF.
    NOTE 5:Mount the DTI card which receives a clock signal into PIM0.
    CONDITIONSDTI0 DTI1 DTI2 DTI3 DTI4
    REMARKS
    SW
    0-1SW
    0-2SW
    0-1SW
    0-2SW
    0-1SW
    0-2SW
    0-1SW
    0-2SW
    0-1SW
    0-2
    When one DTI is
    provided.ONOFF––––––––MP card will receive the
    clock signal from DTI0 at its
    PLO0 input.
    When more than
    one DTI is
    provided.ON OFF OFF ON OFF OFF OFF OFF OFF OFFMP card will receive the
    clock signal from DTI0 at its
    PLO0 input, under normal
    conditions.
    Should a clock failure occur
    with DTI0, MP card will
    automatically switch to the
    PLO1 input which gets clock
    from DTI1. 
    						
    							NEAX2000 IVS2WCS System Manual (PCS)Page 130ND-70920 (E), Issue 1.0
    CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-30DTC-A (DTI)
    PN-30DTC-A (DTI)
    Locations of Lamps, Switches, and Connectors
    SENS
    RU N
    MB
    SW
    PCM
    FRM
    MFRM
    RMT
    MRMT
    AIS
    BL
    JP JPSJPR 
    						
    							CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-30DTC-A (DTI)
    NEAX2000 IVS2WCSSystemManual(PCS)
    ND-70920 (E), Issue 1.0Page 131
    Lamp Indications
    LAMP
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM when this card is normally operating.
    PCM Red Remains lit when detecting PCM signal loss.
    FRM Red Remains lit when detecting Frame Alignment signal loss.
    MFRM Red Remains lit when detecting Multi-Frame Alignment signal loss on
    Time Slot 16.
    RMT Red Remains lit when receiving the alarm from a distant office
    because Frame Alignment signal loss has been detected at the
    distant office.
    MRMT Red Remains lit when receiving the alarm from a distant office
    because Multi-Frame Alignment signal loss has been detected at
    the distant office.
    AIS Red Remains lit when indicating that the pattern of consecutive “1” is
    being received. The distant office transmits this signal for a loop-
    back test distant.
    BL Red B channel status
    ON : More than 10 channels are busy.
    OFF : All channels are idle.
    Flash (60 IPM) : Only one channel is busy.
    Flash (120 IPM) : 2 to 10 channels are busy. 
    						
    							NEAX2000 IVS2WCS System Manual (PCS)Page 132ND-70920 (E), Issue 1.0
    CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-30DTC-A (DTI)
    Switch Settings
    SWITCH NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SENSE
    (Rotary SW)
    NOTE 14-F Set the switch to match the AP Number (04-31) to
    be set by CM05.
    0-3 Not used
    MB (Toggle SW)
    NOTE 2
    UPFor make-busy
    For normal operation
    F
    4AP No.SW-8: ON
    04 05 06 07 08 09 10 11 12 13 14 15
    SW-8: OFF
    20 21 22 23 24 25 26 27 28 29 30 31
    SW No.
    456789ABCDEF
    ON
    DOWN 
    						
    All NEC manuals Comments (0)