NEC Neax 2000 Ivs2 Wcs System Manual
Have a look at the manual NEC Neax 2000 Ivs2 Wcs System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 3 CHAPTER 1 GENERAL INFORMATION This chapter explains the WCS system outline, the equipment name and function, system specifications, system capacity and conditions.
NEAX2000 IVS2WCS System Manual (PCS)Page 4ND-70920 (E), Issue 1.0 CHAPTER 1 GENERAL INFORMATION System Outline SYSTEM OUTLINE The Wireless Communication System (WCS) interfaces with a Personal Station (PS) via a Zone Transceiver (ZT). Three types of system configurations are available: (1) Integrated Type The system provides both PBX and WCS functions. (2) Adjunct Type (Analog Interface) The WCS is an adjunctsystem to the PBX linked by LC-COT connection. (3) Adjunct Type (CCIS Interface) The WCS is an adjunctsystem to the PBX linked by CCIS interface. Figure 1-1shows the system outline of the WCS.
CHAPTER 1 GENERAL INFORMATION System Outline NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 5 Figure 1-1 WCS System Outline CSICOT LC DATCSH ZT SLT PS PS PSPBX with WCS (1) Integrated Type * DtermDLC CSICOT DATCSH ZT PS PS PSWCS LCPBX (2) Adjunct Type (Analog Interface) CSIDTI DATCSH ZT PS PS PSWCS (3) Adjunct Type (CCIS Interface) DTIPBX CCIS NOTE:For the Integrated Type and Adjust Type (CCIS Interface), virtual LC-COT Connection data assignment is required to each PS station. LC SLT * LC SLT DLC Dterm COT : Central Office Trunk ZT : Zone Transceiver CSH : CSI Handler CSI : ZT InterfaceDAT : Digital Announcement Trunk DLC : Digital Line Circuit LC : Line Circuit PS : Personal Station : Virtual LC-COT Connection (NOTE) * COT LC COT LCNOTE NOTE ANALOG
NEAX2000 IVS2WCS System Manual (PCS)Page 6ND-70920 (E), Issue 1.0 CHAPTER 1 GENERAL INFORMATION Card Name and Function CARD NAME AND FUNCTION Ta b l e 1 - 1shows the circuit card name and function for WCS. Table 1-1 WCS Card Name and Function CARD NAMEFUNCTIONAL NAMEFUNCTION OUTLINE PZ-PW122 DC/DC PWR Power Supply Card for Cell Station (Zone Transceiver) Input: DC –24 V Output: DC –48 V (1.7 A) One card per PIM. Max. 16 CS (ZT)s backed up by one card. PN-AP00-A [For Nor th America/Latin America only]DBM Data Base Module Card for WCS Roaming function One card per WCS system. PN-SC00 CCH Common Channel Handler Card Transmits/receives signals on the common signalling channel of No. 7 CCIS. Used for WCS Adjunct Type (CCIS Interface). PN-SC01 DCH D-channel Handler Card Transmits/receives signals on the D-channel of ISDN Primary Rate (23B + D) interface or WCS Roaming interface. PN-SC03-A CSH CS (ZT) Handler Card Provides the D-channel signaling interface and controls max. four CSI cards, eight CS (ZT)s. PN-2CSIA [For Nor th America/ Latin America]CSI 2-line Zone Transceiver Interface Card Used to interface with the ZT, based on ISDN S-interface. Max. two ZTs can be connected per CSI card.
CHAPTER 1 GENERAL INFORMATION Card Name and Function NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 7 PN-2DATA DAT 2-line Digital Announcement Trunk Card This card is used for Announcement Service on WCS. Recording duration: Max. 60 seconds PN-4DATC DAT 4-line Digital Announcement Trunk Card This card is used for Announcement Service on WCS. Recording duration: Max. 120 seconds PN-24DTA-C DTI Digital Trunk Interface (23B + D, 1.5 Mbps) Card Accommodates 24-channel PCM digital lines. Used for WCS Adjunct (CCIS Interface) or for WCS Roaming Interface. PN-30DTC-A DTI Digital Trunk Interface (2 Mbps) Card Accommodates 30-channel PCM digital lines. Used for WCS Adjunct (CCIS Interface) or for WCS Roaming Interface. PZ-M537 EXPMEM Memory Expansion Card for MP Card The following expansions are available when mounted on PN-CP14 (MP) card: Basic Memory expanded Number of Dterm: 384 512 Number of PS : 128 256 Number of ISDN terminal : 64 128 Number of Speed Calling-Station (Station Speed Dial) set : 4000 10000 Table 1-1 WCS Card Name and Function (Continued) CARD NAMEFUNCTIONAL NAMEFUNCTION OUTLINE
NEAX2000 IVS2WCS System Manual (PCS)Page 8ND-70920 (E), Issue 1.0 CHAPTER 1 GENERAL INFORMATION System Specifications SYSTEM SPECIFICATIONS Table 1-2 System Specifications DESCRIPTION SPECIFICATIONS REMARKS Wireless Protocol Based on second generation wireless telephone system standard RCR-STD-28 FCC Sub part D, UTAM complied Distance between PBX and ZT NOTE:At Nominal Voltage of –48 V. Interface with aPBXAnalog station line interface Adjunct Type (Analog Interface) T1 or E1 interface with CCIS Adjunct Type (CCIS Interface) WIRE DIAMETER26 AWG 24 AWG 22 AWG POWER SUPPLY WCS LOCAL WCS LOCAL WCS LOCAL DISTANCE1500 ft. (457 m)2000 ft. (609 m)2000 ft. (609 m)3000 ft. (914 m)3000 ft. (914 m)3300 ft. (1000 m)
CHAPTER 1 GENERAL INFORMATION System Capacity NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 9 SYSTEM CAPACITY NOTE 1:When using a PZ-M537 card, the capacity of PSs can be expanded to 256. NOTE 2:Calling Area is a registered area to search first for a PS location. The calling signal is sent to the ZTs that belong to the Calling Area. Table 1-3 WCS System Capacity DescriptionCAPACITY IntegratedAdjunct (Analog)Adjunct (CCIS ) PSNOTE 1with PZ-M537 256 without PZ-M537 128 ZT 128 CSI 64 CSH 16 PS Simultaneous ConnectionsNOTE 1with PZ-M537 216 without PZ-M537 128 Calling Area 32 ZT per Calling Area 128
NEAX2000 IVS2WCS System Manual (PCS)Page 10ND-70920 (E), Issue 1.0 CHAPTER 1 GENERAL INFORMATION Time Slot Allocation TIME SLOT ALLOCATION CSH As shown inFigure 1-2, the CSH (PN-2CSIA) card uses the time slot on the basic memory Highway 4. Therefore, the total number of time slots for all CSH card must be 128 time slots or less including all other application processor cards, which use the Highway 4. Figure 1-2 Accommodation of CSH into TDSW CSI The CSI (PN-2CSIA) card uses eight L/T time slots per card. CSH AP00 PRT4TIMESLOTS/CARD 1 TIME SLOT/CARD 25 TIME SLOTS/CARD DTI CCH1 TIME SLOT/CARD FP1 FP0 FP2 FP3 TDSW (1024 TIME SLOTS) MAX. 128 TIME SLOTS MAX. 128 TIME SLOTS MAX. 128 TIME SLOTS MAX. 128 TIME SLOTS FOR AP CARDS: MAX. 256 TIME SLOTS PER SYSTEM FOR L/T CARDS: MAX. 512 TIME SLOTS PER SYSTEM 30DTI: MAX. 32 TIME SLOTS/CARD BASIC HIGHWAY 4: Max. 128 TIME SLOTS PERSYSTEM EXPANDED HIGHWAY 6: MAX. 128 TIME SLOTS PER SYSTEMHW4 HW6 DTI 24 DTI: MAX. 24 TIME SLOTS/CARD
CHAPTER 1 GENERAL INFORMATION Outline of Multi-Site Roaming NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 11 OUTLINE OF MULTI-SITE ROAMING The PBX supports the JT-Q931a protocol and JT-11582 for signaling at Q-reference point between PBXs on the private network. By supporting this protocol, the PSs can be used in any Calling Area on the private network. Figure 1-3 System Outline of Multi-Site Roaming PBX APBX B ZTZT PS PSROA MING When a PS roams over the adjoining PBX’s Calling Area When a PS roams over other Calling Area through the relaying office PBX APBX B ZTZT PS PSROAMING PBX C ZT Dp Channel Private Line Dp Channel Private LineDp Channel Private Line NOTE:Also to the relaying office (PBX C), the installation and the data assignment for Multi-Site Roaming are required. (JT-Q931a) (JT-Q931a) (JT-Q931a)
NEAX2000 IVS2WCS System Manual (PCS)Page 12ND-70920 (E), Issue 1.0 CHAPTER 1 GENERAL INFORMATION Outline of Multi-Site Roaming System Configuration Figure 1-4shows the system configuration for Multi-Site Roaming. Figure 1-4 System Configuration of Multi-Site Roaming HOME PBX CSI DBM PLO DTI CSH DCH ZT V IRTUAL LC V IRTUAL TRK V IRTUAL LC V IRTUAL TRK PUBLIC NETWORK PS PS TRK VISITOR PBX CSI DBM PLO DTI CSH DCH ZT VIRTUAL LC VIRTUAL TRK VIRTUAL LC VIRTUAL TRK TRK PS PS Dp Channel Private Line (JT-Q931-a) Roaming The equipment in this square is required for Multi-Site Roaming.