    							CHAPTER 2 INSTALLATION
    Mounting CSI Card
    NEAX2000 IVS2WCSSystemManual(PCS)
    ND-70920 (E), Issue 1.0Page 33
    MOUNTING CSI CARD
    (1) Before mounting the CSI (PN-2CSIA) card, confirm the correct switch settings.
    SeeCHAPTER 4.
    (2) Mount the CSI card in the LT slots of PIM0 though PIM7.
    PIM0-7: LT00-LT07 slotsATTENTIONContents
    Static SensitiveHa ndl ing
    Prec au tio ns Requ ired 
    						
    							NEAX2000 IVS2WCS System Manual (PCS)Page 34ND-70920 (E), Issue 1.0
    CHAPTER 2 INSTALLATION
    Connection of ZT
    CONNECTION OF ZT
    Connect the cable to a ZT via the MDF as described in this section.
     Location ofLT slots andLTC connectors for ZT (Figure 2-1)
     MDF Cross connection for ZT (Figure 2-2)
    Figure 2-1 Location of LT Slots and LTC Connectors for ZT
    LT C 0
    01
    02
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25RA0
    TA 0
    RA1
    TA 1
    RA0
    TA 0
    RA1
    TA 1
    RA0
    TA 0
    RA1
    TA 1
    MJRB0
    TB0
    RB1
    TB1
    RB0
    TB0
    RB1
    TB1
    RB0
    TB0
    RB1
    TB1
    MN 26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    LT 0 0
    SLOT
    LT 0 1
    SLOT
    LT 0 2
    SLOT
    LT C 1
    01
    02
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25RA0
    TA 0
    RA1
    TA 1
    RA0
    TA 0
    RA1
    TA 1
    RA0
    TA 0
    RA1
    TA 1RA0
    TA 0
    RA1
    TA 1
    RA0
    TA 0
    RA1
    TA 1 RB0
    TB0
    RB1
    TB1
    RB0
    TB0
    RB1
    TB1
    RB0
    TB0
    RB1
    TB1RB0
    TB0
    RB1
    TB1
    RB0
    TB0
    RB1
    TB1 26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    LT 0 3
    SLOT
    LT 0 4
    SLOT
    LT 0 5
    SLOT
    LT C 2
    01
    02
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    2526
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    LT 0 8
    SLOT
    LT 0 7
    SLOT
    LT 0 6
    SLOT
    LT C 3
    01
    02
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    2526
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    LT 1 1
    SLOT
    LT 1 0
    SLOT
    LT 0 9
    SLOT L
    T
    1
    1 L
    T
    1
    0 L
    T
    0
    9 L
    T
    0
    8 L
    T
    0
    7 L
    T
    0
    6 L
    T
    0
    5 L
    T
    0
    4 L
    T
    0
    3 L
    T
    0
    2 L
    T
    0
    1 L
    T
    0
    0 
    						
    							CHAPTER 2 INSTALLATION
    Connection of ZT
    NEAX2000 IVS2WCSSystemManual(PCS)
    ND-70920 (E), Issue 1.0Page 35
    Figure 2-2 MDF Cross Connection for ZT
    CAUTION: Incorrect wiring may cause severe damage to the equipment.
     
    
    
    
    
    
    
    
    
    
    PBX
    (PIM0-7)
    BWB
    CSI
    TWISTED-PAIR
    CABLEMDF
    LTC0/LTC1/LTC2 CONNECTORModular
    Connector
    To Z T
    1RA0 26RB0
    2TA0 27TB0
    3RA1 28RB1
    4TA1 29TB1
    5RA2 30RB2
    6TA2 31TB2
    7RA3 32RB3
    8TA3 33TB3
    934
    10 35
    11 36
    12 37
    13 38
    14 39
    15 40
    16 41
    17 42
    18 43
    19 44
    20 45
    21 46
    22 47
    23 48
    24 49
    25 50
    ZT No. 0
    ZT No. 1
    ZT No. 2
    ZT No. 3
    Modular Jack
    (RJ-45)
    Modular plugTA
    RA TB
    RB
    ZT
    NOTE:Confirm that all feed polarity TA/TB
    and RA/RB is normal before con-
    necting ZT to RJ-45 Modular jack.
    TA/TB minus
    RA/RB plus
    MDF
    TA
    RA
    RB
    TB
    LTC CONNECTOR 
    						
    							NEAX2000 IVS2WCS System Manual (PCS)Page 36ND-70920 (E), Issue 1.0
    CHAPTER 2 INSTALLATION
    Connection of ZT
    Figure 2-3 MDF Cross Connection via MDF for ZT
    12
    3
    4
    5
    6
    7 8
    Modular
    Connector
    (8)(1)
    NOTE:RJ-45 Modular Jack is highly recommended.
    Keep all wiring straight to the jack and perform all reverses at the cross connect for
    future changes.
    TERMINAL
    NUMBERCOLORTERMINAL
    NUMBERFUNCTION POLARITY
    CSI
    TERMINAL TERMINAL
    EQUIPMENTCSI SIGNAL FEED
    1 blue a Not used Not used
    2 orange b Not used Not used
    3 black c Transmission Reception + – RA
    4 red d Reception Transmission + – TA
    5 green e Reception Transmission – + TB
    6 yellow f Transmission Reception – + RB
    7 brown g Not used Not used
    8 slate h Not used Not used 
    						
    							CHAPTER 2 INSTALLATION
    Installation for Multi-Site Roaming
    NEAX2000 IVS2WCSSystemManual(PCS)
    ND-70920 (E), Issue 1.0Page 37
    INSTALLATION FOR MULTI-SITE ROAMING
    (1) Before mounting the DTI (PN-24DTA/PN-30DTC), DCH (PN-SC01), DBM (PN-AP00-A)
    card, set the MB switch to UP position, and set the other switches to appropriate position.
    SeeCHAPTER 4.
    (2) Mount the DTI, DCH, DBM card in AP slots of PIM0 though PIM7.
    PIM0-7: AP00-AP11 slots
    (3) After mounting the card, set the MB switch to DOWN position to put the card in service.
    (4) To select PLO in the MP card, set the switches of the MP card. SeeCHAPTER 4.
    (5) Connect the cable to a CSU via the MDF for DTI as shown inFigure 2-4.
     Location of AP Slots and LTC Connectors for DTI (Figure 2-5)
     Example of MDF Cross Connection for DTI (Figure 2-6)
    Figure 2-4 DTI Cable Connection via MDF
    CSU MDF
    TWISTED-PAIR
    CABLE BWBPBX
    (PIM0-PIM7)
    LT C 0 / LT C 1 / LT C 2 / LT C 3
    CONNECTOR DTI
    NOTE:The CSU must be installed to interface with the network, and must be installed on
    the premises where the PBX is.
    MAX. 200 m (655 ft.) .... 24DTI
    MAX. 400 m (1310 ft.) .. 30DTI 
    						
    							NEAX2000 IVS2WCS System Manual (PCS)Page 38ND-70920 (E), Issue 1.0
    CHAPTER 2 INSTALLATION
    Installation for Multi-Site Roaming
    Figure 2-5 Location of AP Slots and LTC Connectors for DTI
    LT C 0
    01
    02
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25RA
    TA
    RA
    TA
    RA
    TA
    MJRB
    TB
    RB
    TB
    RB
    TB
    MNRA
    TA
    RA
    TA
    RA
    TARB
    TB
    RB
    TB
    RB
    TBRA
    TA
    RA
    TA
    RA
    TARB
    TB
    RB
    TB
    RB
    TBRA
    TA
    RA
    TA
    RA
    TARB
    TB
    RB
    TB
    RB
    TB 26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    AP00
    SLOT
    AP01
    SLOT
    AP02
    SLOT
    LT C 1
    01
    02
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    2526
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    AP03
    SLOT
    AP04
    SLOT
    AP05
    SLOT
    LT C 2
    01
    02
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    2526
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    AP08
    SLOT
    AP07
    SLOT
    AP06
    SLOT
    AP11
    SLOT
    AP09
    SLOT
    AP10
    SLOT
    LT C 3
    01
    02
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    2526
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50 L
    T
    1
    1
    /
    A
    P
    1
    1 L
    T
    1
    0
    /
    A
    P
    1
    0 L
    T
    0
    9
    /
    A
    P
    0
    9 L
    T
    0
    8
    /
    A
    P
    0
    8 L
    T
    0
    7
    /
    A
    P
    0
    7 L
    T
    0
    6
    /
    A
    P
    0
    6 L
    T
    0
    5
    /
    A
    P
    0
    5 L
    T
    0
    4
    /
    A
    P
    0
    4 L
    T
    0
    3
    /
    A
    P
    0
    3 L
    T
    0
    2
    /
    A
    P
    0
    2 L
    T
    0
    1
    /
    A
    P
    0
    1 L
    T
    0
    0
    /
    A
    P
    0
    0 
    						
    							CHAPTER 2 INSTALLATION
    Installation for Multi-Site Roaming
    NEAX2000 IVS2WCSSystemManual(PCS)
    ND-70920 (E), Issue 1.0Page 39
    Figure 2-6 Example of MDF Cross Connection for DTI
    PIM 0
    JP MDF PN-24DTA/PN-30DTC
    AP05
    RA
    RB
    TA
    TB17
    42
    18
    4317
    42
    18
    43RA
    RB
    TA
    TBTO CSU LT C 1
    RECEIVE
    TRANSFER
    17
    18
    19
    20RA
    TA42
    43
    44
    45RB
    TB LT C 1 ( J )42
    43
    44
    45RB
    TB17
    18
    19
    20RA
    TA LT C 1 ( P ) 
    						
    							NEAX2000 IVS2WCS System Manual (PCS)Page 40ND-70920 (E), Issue 1.0
    This page is for your notes. 
    						
    							NEAX2000 IVS2WCSSystemManual(PCS)
    ND-70920 (E), Issue 1.0Page 41
    CHAPTER 3
    SYSTEM DATA
    PROGRAMMING
    This chapter explains the programming procedure to provide the WCS
    feature to the PBX. 
    						
    							NEAX2000 IVS2WCS System Manual (PCS)Page 42ND-70920 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    How to Read This Chapter
    HOW TO READ THIS CHAPTER
    In the programming procedure, the meaning of (1), (2), and markings are as follows.
    (1) : 1st Data
    (2) : 2nd Data
    : Initial Data
    With the system data clear command (CM00, CM01), the data with this marking is automatically
    assigned for each command.
    : A reset of the MP card is required after data setting.
    Press SW1 switch on the MP card.
    : A reset of the DBM card is required after data setting.
    Set the Make Busy switch to UP and then DOWN.
    For general description, operating procedure, service conditions of WCS features, refer to the
    WCS Features and Specifications.
    INITIAL
    DBM INITIAL 
    						
    All NEC manuals Comments (0)