CHAPTER 4 CIRCUIT CARD INFORMATION PZ-PW122 (DC/DC PWR) NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 113 Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SWON For turning AC power on OFF For turning AC power off CAUTION When the operating power is being supplied to this circuit card, do not plug/unplug this circuit card into/from its mounting slot. OFF ON
NEAX2000 IVS2WCS System Manual (PCS)Page 114ND-70920 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PZ-M537 (EXPMEM) PZ-M537 (EXPMEM) Locations of Lamps, Switches, and Connectors FAC E REAR CONNR: To CONN connector on PN-CP14 (MP) or PN-AP00-B (AP00) SW CONNR
CHAPTER 4 CIRCUIT CARD INFORMATION PZ-M537 (EXPMEM) NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 115 Lamps Indications This card has no lamps. Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW (DIP SW) 1 For normal operation (Memory backup ON) OFF Not used (Memory backup OFF) 2 Not used 3 Not used 4 Not used 1234ON ON OFF OFF OFF
NEAX2000 IVS2WCS System Manual (PCS)Page 116ND-70920 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-SC03-A (CSH) PN-SC03-A (CSH) Locations of Lamps, Switches, and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. DOPE7 Green Remains lit when No. 7 circuit D channel link is connected. DOPE6 Green Remains lit when No. 6 circuit D channel link is connected. DOPE5 Green Remains lit when No. 5 circuit D channel link is connected. DOPE4 Green Remains lit when No. 4 circuit D channel link is connected. DOPE3 Green Remains lit when No. 3 circuit D channel link is connected. DOPE2 Green Remains lit when No. 2 circuit D channel link is connected. DOPE1 Green Remains lit when No. 1 circuit D channel link is connected. DOPE0 Green Remains lit when No. 0 circuit D channel link is connected. SENSE RUN MB DOPE7 DOPE6 DOPE5 DOPE4 DOPE3 DOPE2 DOPE1 DOPE0 SW1
CHAPTER 4 CIRCUIT CARD INFORMATION PN-SC03-A (CSH) NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 117 Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1:Set the groove on the switch to the desired position. NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/ unplugging the circuit card. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) NOTE 14-F Set the switch to match the AP Number (04-31) to be set by CM05. 0-3 Not used MB (Toggle SW) NOTE 2 UP For make-busy For normal operation SW1 (Piano Key SW)1 Not used 2 Not used 3 Not used 4 AP No. 04-15 AP No. 20-31 F 4AP No.SW1-1: ON04 05 06 07 08 09 10 11 12 13 14 15 SW1-1: OFF20 21 22 23 24 25 26 27 28 29 30 31 SW No.456789ABCDEF ON DOWN 4 3 2 1 OFF ON OFF OFF OFF ON OFF
NEAX2000 IVS2WCS System Manual (PCS)Page 118ND-70920 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-2CSIA (CSI) PN-2CSIA (CSI) Locations of Lamps, Switches, and Connectors OPE B13 LB B12 B11 B10 B02 B03 B01 B00 DL1 DL0
CHAPTER 4 CIRCUIT CARD INFORMATION PN-2CSIA (CSI) NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 119 Lamp Indications LAMP NAMECOLOR FUNCTION OPE Green Remains lit when the corresponding circuit is in use. LB Red Remains lit when a loop-back is in progress. B13 Red Not used (Flash [60 IPM]) B12 Red B channel status ON : B2 channel of the No. 1 circuit is in use. OFF : B2 channel of the No. 1 circuit is in idle. Flash (60 IPM) : ZT is not connected to the No. 1 circuit. ZT is in make-busy status. B11 Red B channel status ON : B1 channel of the No. 1 circuit is in use. OFF : B1 channel of the No. 1 circuit is in idle. Flash (60 IPM) : ZT is not connected to the No. 1 circuit. ZT is in make-busy status. B10 Red B channel status ON : B0 channel of the No. 1 circuit is in use. OFF : B0 channel of the No. 1 circuit is in idle. Flash (60 IPM) : ZT is not connected to the No. 1 circuit. ZT is in make-busy status. B03 Red Not used (Flash [60 IPM]) B02 Red B channel status ON : B2 channel of the No. 0 circuit is in use. OFF : B2 channel of the No. 0 circuit is in idle. Flash (60 IPM) : ZT is not connected to the No. 0 circuit. ZT is in make-busy status. B01 Red B channel status ON : B1 channel of the No. 0 circuit is in use. OFF : B1 channel of the No. 0 circuit is in idle. Flash (60 IPM) : ZT is not connected to the No. 0 circuit. ZT is in make-busy status. (Continued)
NEAX2000 IVS2WCS System Manual (PCS)Page 120ND-70920 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-2CSIA (CSI) Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE:Set the groove on the switch to the desired position. LAMP NAMECOLOR FUNCTION B00 Red B channel status ON : B0 channel of the No. 0 circuit is in use. OFF : B0 channel of the No. 0 circuit is in idle. Flash (60 IPM) : ZT is not connected to the No. 0 circuit. ZT is in make-busy status. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK DL0 (Rotary SW) NOTE0-F For normal operation 1-F Not used DL1 (Rotary SW) NOTE0-F For normal operation 1-F Not used 0 0 0 0
CHAPTER 4 CIRCUIT CARD INFORMATION PN-AP00-A (DBM) NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 121 PN-AP00-A (DBM) Locations of Lamp, Switches, and Connectors RS3 RS2 RS1 RS0 SENSE RU N MB SW0 WE L3 L2 L1 L0 SW1 J16
NEAX2000 IVS2WCS System Manual (PCS)Page 122ND-70920 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-AP00-A (DBM) Lamp Indications Switch Settings LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. WE Red Not used L0-L3 Green Second data setting value for CMD001>250 0 1 (port0)-3 (port2) L3 Indication of transmitting status of port 0Indication of CTS signal status on por t0-2 L2 Indication of transmitting status of port 1Indication of DCD signal status on port 0-2 L1 Indication of transmitting status of port 2Indication of TXD signal status on port 0-2 L0 Indication of transmitting status of port 3Indication of RXD signal status on port 0-2 SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) NOTE 14-F Set the switch to match the AP Number (04-15) to be set by CM05. 0-3 Not used MB (Toggle SW) NOTE 2 UP For make-busy For normal operation F 4AP No.04 05 06 07 08 09 10 11 12 13 14 15 SW No.456789ABCDEF ON DOWN