NEC Neax 2000 Ivs2 Wcs System Manual
Have a look at the manual NEC Neax 2000 Ivs2 Wcs System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
CHAPTER 3 SYSTEM DATA PROGRAMMING Trunk Data Programming (For Adjunct Analog) NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 63 DESCRIPTION DATA Specify the DTMF Sender release timing to the trunk route. (1) (2)YY=46 00-63 : Trunk Route No. 0:2sec. 1:4sec. 2:6sec. 3:8sec. 4:12sec. 5:14sec. 6:16sec. 7:10sec. Specify the designated seizure of trunks on each station basis. (1) (2)YY=98 00-63 : Trunk Route No. 0 : Allowed Specify the COT card Terminating Imped- ance. (1) (2)YYY=100 00-63 : Trunk Route No. 0 : 600 ohm/complex BNW for Inte- grated Type and Adjunct Type (CCIS Interface) 2 : 600 ohm/600 ohm for Adjunct Type (Analog Interface) Assign the trunk to be seized on each PS station basis. (1) (2)YY=16 X-XXXXXXXX : PS Station No. D000-D255 : Trunk No. CM35 D CM12 END
NEAX2000 IVS2WCS System Manual (PCS)Page 64ND-70920 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming WCS FEATURE PROGRAMMING Announcement-PS No Answer/Announcement-PS Out of Cell See the WCS Features and Specifications. DESCRIPTION DATA Assign a Digital Announcement Trunk (DAT) circuit number to the required LEN. NOTE 1:The DAT circuit No. must be as- signed to the first LEN (Level 0), the third LEN (Level 2), the fifth LEN (Level 4), and the seventh LEN (Level 6) of each LT slot. NOTE 2:EB000 and EB001 are dedicated to built-in Digital Announcement Trunk of MP card.(1) (2)000-763: LEN 0-7 (PIM0-7) + 00-63 (Port No.) EB002-EB127: Digital Announcement Trunk circuit No. For PIM 0/1 : EB002-EB031 For PIM 2/3 : EB032-EB063 For PIM 4/5 : EB064-EB095 For PIM 6/7 : EB096-EB127 Assign a tenant No. to a PS station. (1) (2)YY=04 X-XXXXXXXX: PS Station No. 00 : Tenant 00 1 : Tenant 01 63 : Tenant 63 Provide PS No-Answer feature. (1) (2)504 0 : Available 1 : Not Available Specify types of No-Answer Timer. (1) (2)085 0: No-Answer timer (CM41 Y=0>86) 1: No-Answer timer (CM41 Y=0>01) Specify the message reply timer for Announcement -PS No Answer. (1) (2)Y=0 01 01-30: 4-120 sec. in 4 sec. increments If no data is set, the default setting is 32-36 seconds. Specify the duration of message for Announcement -PS No Answer. (1) (2)Y=0 75 01-99: 4-396 sec. in 4 sec. increments If no data is set, the default setting is 116-120 seconds. CM12 START CM10 CM41 CM08 ~ A
CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 65 DESCRIPTION DATA Specify the duration of message for Announcement-PS Out of Cell/PS Power Off. (1) (2)Y=0 84 01-99: 4-396 sec. in 4 sec. increments If no data is set, the default setting is 116-120 seconds. Specify the message reply timer for Announcement-PS No Answer. NOTE:CM41 Y=0>01 is effective only when CM08>085 is set to 0. (1) (2)Y=0 86 01-99: 4-396 sec. in 4 sec. increments If no data is set, the default setting is 36-40 seconds. Specify the message reply timer for Announcement-PS Out of Cell/PS Power Off. (1) (2)Y=0 85 01-99: 4-396 sec. in 4 sec. increments If no data is set, the default setting is 8- 12 seconds. Provide the Announcement Service. (1) (2)Y=5 00: PS No-Answer 02: PS Out of Cell/PS Power Off 0500 : Provided NONE : Not provided Assign the function for each Digital Announcement Trunk. (1) (2)YY=00 002-127 : Digital Announcement Trunk Circuit No. (EB002- EB127) 1300-1363 : PS No Answer Message Group No. 00-63 1500-1563 : PS Out of Cell/PS Power Off Message Group No. 00-63 NONE : None Assign the message group for PS No Answer to each tenant. (1) (2)YY=10 00-63 : Tenant No. 00-63 : Message Group No. NONE : None Assign the message group for PS Out of Cell/PS Power Off to each tenant. (1) (2)YY=12 00-63 : Tenant No. 00-63 : Message Group No. NONE : None CM41 A CM48 CM49 B
NEAX2000 IVS2WCS System Manual (PCS)Page 66ND-70920 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming To record/replay/delete a message: There are two methods to record/replay/delete a message from a PS or a station. (1) To record/replay/delete a message from a station or a PS by dialling an access code assigned by CM20, do the following programming. This method is available only for the IntegratedType. (2) To record/replay/delete a message from a PS by dialling “1”, “2”, “3”, do the following programming. This method is available for both the Integrated Type and the AdjunctType. DESCRIPTION DATA Assign the Class of Service for the Announcement Service to a certain PS/ station. (1) (2)CM12 YY=02 (Service Restriction Class A) CM15 YY=33 (Digital Announcement Trunk Access: Record/Replay/Delete) 00-15 : Service Restriction Class A 0 : Restricted 1 : Allowed Assign the access codes to record/replay/ delete the message. (1) (2)Y=0-3 (Numbering Plan Group 0-3) X-XXXX: Access Code A100 : Record A101 : Replay A102 : Delete CM12 B END CM15 CM20
CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 67 For operating procedure, see the following pages. DESCRIPTION DATA Assign the Class of Service for the Announcement Service to a certain PS station. NOTE:By this method, while a PS is specified to “Allowed” to record/ replay/delete a message by CM15 YYY=110, the PS cannot originate a call. Specify to “Restricted” by CM15 YYY=110 again after a message is completed to record/replay/ delete. (1) (2)CM12 YY=02 (Service Restriction Class A) CM15 YYY=110 (Digital Announcement Trunk Access: Record/Replay/Delete) 00-15 : Service Restriction Class A 0 : Restricted 1:Allowed CM12 B END CM15
NEAX2000 IVS2WCS System Manual (PCS)Page 68ND-70920 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming Operating Procedure for Announcement Service (1) By dialling predetermined access cord from a station or a PS (For Integrated Type) To replay an announcement: 1. Dial the access code to replay the announcement assigned by CM20. 2. Dial the Digital Announcement Trunk Circuit Number (000-127). 3. Press the SEND key. 4. Receive a message. 5. Press the END key. To record an announcement: 1. Dial the access code to record the announcement assigned by CM20. 2. Dial the Digital Announcement Trunk Circuit Number (000-127). 3. Press the SEND key. 4. Receive a service set tone. 5. Record a message. 6. Press the END key. To delete an announcement: 1. Dial the access code to delete the announcement assigned by CM20. 2. Dial the Digital Announcement Trunk Circuit Number (000-127). 3. Press the SEND key. 4. Receive a service set tone. 5. Press the END key.
CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 69 (2) By dialling “1”, “2”, “3”, from a PS (For Integrated Type and AdjunctType) To replay an announcement: 1. Dial “2”. 2. Dial the Digital Announcement Trunk Circuit Number (000-127). 3. Press the SEND key. 4. Receive a message. 5. Press the END key. To record an announcement: 1. Dial “1”. 2. Dial the Digital Announcement Trunk Circuit Number (000-127). 3. Press the SEND key. 4. Receive a service set tone. 5. Record a message. 6. Press the END key. To delete an announcement: 1. Dial “3”. 2. Dial the Digital Announcement Trunk Circuit Number (000-127). 3. Press the SEND key. 4. Receive a service set tone. 5. Press the END key.
NEAX2000 IVS2WCS System Manual (PCS)Page 70ND-70920 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming Call Forwarding-Not Available Refer to the WCS Features and Specifications. DESCRIPTION DATA Assign the destination VMS station for Call Forwarding-Not Available. (1) (2)YY=20 00-63: Tenant No. of Virtual PS X-XXXXXXXX: VMS Station No. Assign the access code to set/cancel Call Forwarding when the incoming call is not available, and set the access code to replay the message. (1) (2)Y=0-3 (Numbering Plan Group 0-3) X-XXXX: Access Code A089: Call Forwarding-Not Available Set A090: Call Forwarding-Not Available Cancel A091: Call Forwarding-Not Available Replay Specify whether confirmation of message existence by Special Dial Tone is available or not. If the second data is set to 0, the Special Dial Tone is sent when a message exists. (1) (2)Y=2 12 (Confirmation by DialTone) 0 : Available 1 : Not available Set the Class of Service for Call Forward- ing-NotAvailabletoeachPSstation. (1) (2)CM12 YY=02 (Service Restriction Class A) CM15 YYY=115 (Call Forwarding-Not Available) 00-15 : Service Restriction Class A for the Vir tual PS Station 0 : Restricted 1:Allowed CM48 START CM51 CM15 END CM12 CM20 INITIAL
CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 71 Calling Name Display-PS Refer to the WCS Features and Specifications. Refer to the following manuals for the name display feature programming. Feature Programming Manual : Alphanumeric Display, Caller ID Class, Guest Name Display CCIS System Manual : Calling Name Display-CCIS DESCRIPTION DATA Specify the terminal kind of the PS as “D termPS II”. (1) (2)YY=15 X-XXXXXXXX: PS station No. (Assigned by CM1C) 00 : D termPS II Specify the kind of the ZT as “D termPS II type ZT”. (1) (2)YY=19 000-127 : ZT No. 00 : D termPS II type ZT Assign a Service Restriction Class to each station. (1) (2)YY=02 X-XXXXXXXX: PS station No. (Assigned by CM1C) XX ZZ XX: Service Restriction Class A (00-15 ) Provide Calling Name Display to PS NOTE:The previous PS D termdoes not provide the Calling Name Display feature; therefore, CM15 YYY=123 should be set to “1” Not Available. Set data to “0” Available if providing service for the D termPS II. (1) (2)YYY=123 00-15 : Service Restriction Class A assigned by CM12 YY=02 0:Available 1:NotAvailable START CM1D CM15 CM12 CMAD END
NEAX2000 IVS2WCS System Manual (PCS)Page 72ND-70920 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming Group Call-Automatic Conference (6/10-Party) Refer to the WCS Features and Specifications. DESCRIPTION DATA Assign a Conference Trunk card number to the required LEN.(1) (2)000-763 : LEN 0-7 (PIM0-7) + 00-63 (Port No.) ED00-ED03: Conference Trunk Card No. Assign the stations which belongs to each paging group, and their number within the group. A maximum of 9 stations can be paged simultaneously except the conference leader. NOTE 1:Single line telephones, D terms and PSs can be assigned as the station within the group. A vir tual-line cannot be assigned. NOTE 2:A station can belong to plural group. (1) (2)YY=00-07: Simultaneous Paging Group 0-7 00-15 : Serial No. within the Group X-XXXXXXXX: Station No. Assign a Service Restriction Class to each station. (1) (2)YY=02 X-XXXXXXXX: Station No. XX YY XX : Service Restriction Class A (00-15 ) Allow the Service Restriction Class A to page the conference. (1) (2)YYY=119 00-15: Service Restriction Class A assigned by CM12 YY=02 0: Allowed START CM56 A CM12 CM15 CM10 INITIAL