    							CHAPTER 2 INSTALLATION
    Precautions
    NEAX2000 IVS2WCSSystemManual(PCS)
    ND-70920 (E), Issue 1.0Page 23
    Tu r n i n g P o w e r O N
    (1) Check the switch position of each PZ-PW121 card before turning power on.
     Make sure that the AC120V/240V selector switch is positioned to appropriate voltage for
    each country (AC120V or AC240V).
     Make sure that the battery mode selector switch is positioned as shown below to meet the
    kind of battery:
    (2) Turn the SW1 switches of all the PZ-PW121 cards to ON. First, turn ON PIM1 to PIM7.
    Then, turn ON PIM0 last of all.
    Caution
    1. When the operating power is being supplied to the PZ-PW121 card, do not plug/unplug
    this circuit card into/from its mounting slot.
    2. When the system is configured with two or more PIMs, the BUS cable is providing gang
    control for the PZ-PW121 card of PIM0 and other PIMs. Therefore, if the power of PIM0 is
    off, no power is supplied to the wholesystem even when the power switch(s) of other
    PIMs are left on. Note, however, that the battery continues to charge even under these
    circumstances.
    3. Do not turn off the PZ-PW121 card on PIM1 to PIM7 when thesystem isoperating.
    SW
    240 V 100 V/120 V
    ON OFF
    12
    SW101
    1:Notused
    2 : ON (SEAL/FLOAT2)
    OFF (OPEN/FLOAT1) 
    						
    							NEAX2000 IVS2WCS System Manual (PCS)Page 24ND-70920 (E), Issue 1.0
    CHAPTER 2 INSTALLATION
    Precautions
    Tu r n i n g P o w e r O F F
    (1) Before turning power off ensure that all circuits are not in use.
    (2) Turn the SW1 switches of all the PZ-PW121 cards to OFF. First, turn OFF PIM0. Then, turn
    OFF PIM1 to PIM7. 
    						
    							CHAPTER 2 INSTALLATION
    Required Equipment
    NEAX2000 IVS2WCSSystemManual(PCS)
    ND-70920 (E), Issue 1.0Page 25
    REQUIRED EQUIPMENT
    Ta b l e 2 - 1shows the equipment required to provide the WCS interface to the system.
    Table 2-1 WCS Required Equipment
    EQUIPMENT DESCRIPTION QUANTITY REMARKS
    PZ-PW122
    (DC/DC PWR)–48V Power supply card for ZT 1-8 One per PIM
    16 ZT powered
    /card
    PWR CNT CA-D Power Control Cable-D (between
    PW121/PW122 and BWB)1-7 For PIM1-7
    PWR CNT CA-E Power Control Cable-E (between
    PW121/PW122 and BWB)1ForPIM0
    PN-2CSIA (CSI) ZT Interface card 1-64 2 ZT/card
    PN-SC03-A (CSH) ZT Handler card 1-16 4 CSI/card
    PN-2DATA (DAT) Digital Announcement Trunk N N: As required for
    Announcement
    Service PN-4DATC (DAT)
    PZ-M537
    (EXPMEM)Memory Expansion card 1 For more than 128
    PS
    PN-4COT Central Office Trunk N For Adjunct Type
    (Analog Interface)
    4COT: 4PS/card
    8COT: 8PS/card PN-8COT Central Office Trunk N
    PN-24DTA-C (DTI) 24-channel DTI card 1-8 For Adjunct Type
    (CCIS Interface)
    PN-30DTC-A
    (DTI)30-channel DTI card 1-4
    PN-SC00 (CCH) Common Channel Handler card 1-8 
    						
    							NEAX2000 IVS2WCS System Manual (PCS)Page 26ND-70920 (E), Issue 1.0
    CHAPTER 2 INSTALLATION
    Required Equipment
    PN-24DTA-C
    (24DTI)24-channel DTI card 1-8 For Roaming
    PN-30DTC-A
    (30DTI)30-channel DTI card 1-4
    PN-SC01 (DCH) D-channel Handler card 1-8
    PN-AP00-A (DBM) Roaming Data Base Module card 1
    Table 2-1 WCS Required Equipment (Continued)
    EQUIPMENT DESCRIPTION QUANTITY REMARKS 
    						
    							CHAPTER 2 INSTALLATION
    Installation Procedure
    NEAX2000 IVS2WCSSystemManual(PCS)
    ND-70920 (E), Issue 1.0Page 27
    INSTALLATION PROCEDURE
    Install the equipment for WCS according to the procedure shown inFigure 2-2.Figure 2-3shows
    the procedure for Multi-Site Roaming.
    Figure 2-2 Installation Procedure
    START
    MOUNTING PW122 CARD
    Pag e 31 Pag e 29
    More than 128 PS required?
    Ye s No
    CONNECTION OF ZT
    MOUNTING CSH CARDPage 32
    END
    MOUNTING CSI CARDPage 33
    Page 34
    MOUNTING EXPMEM CARD 
    						
    							NEAX2000 IVS2WCS System Manual (PCS)Page 28ND-70920 (E), Issue 1.0
    CHAPTER 2 INSTALLATION
    Installation Procedure
    Figure 2-3 Installation Procedure for Multi-Site Roaming
    START
    CABLE CONNECTION
    END
    MOUNTING DTI, DCHPag e 37
    Pag e 37AND DBM CARD
    VIA MDF
    SELECTION OF PLO IN
    MP CARD 
    						
    							CHAPTER 2 INSTALLATION
    Mounting PW122 Card
    NEAX2000 IVS2WCSSystemManual(PCS)
    ND-70920 (E), Issue 1.0Page 29
    MOUNTING PW122 CARD
    Mount the PW122 card into the PIM as shown inFigure 2-4.
    (1) Attach four screws preliminary to the PZ-PW122 card.
    (2) Mount the PZ-PW122 card into the PIM which accommodates the CSI cards, and fasten the
    screws.
    NOTE:Screws are attached to the PZ-PW122 card.
    Figure 2-4 Mounting PZ-PW122 into PIM
    ATTENTIONContents
    Static SensitiveHa ndl ing
    Prec au tio ns Requ ired
    PIM
    PZ-PW122 
    						
    							NEAX2000 IVS2WCS System Manual (PCS)Page 30ND-70920 (E), Issue 1.0
    CHAPTER 2 INSTALLATION
    Mounting PW122 Card
    (3) Connect the PWR CNT CA-E or PWR CNT CA-D, and POWER OUTPUT
    CABLE (–48 V, E) to the PZ-PW122 card as shown inFigure 2-5.
    Figure 2-5 Cable Connection between PZ-PW121/PZ-PW122 and BWB
    ATTENTIONContents
    Static SensitiveHa ndl ing
    Prec au tio ns Requ ired
    PWR CNT CA-E (FOR PIM0)
    PWR CNT CA-D (FOR PIM1 TO PIM7)PWR0B PWR1 PZ-PW121 BWB (BACK WIRING BOARD)PIM
    PWR0CPWR0A
    POWER OUTPUT CABLE (+90 V, CR, E) PZ-PW122
    POWER OUTPUT CABLE (+5 V, -27 V, E)
    POWER OUTPUT CABLE (-48 V, E)CARD SLOT AREA
    LTC CONNECTOR AREA
    CN103 
    						
    							CHAPTER 2 INSTALLATION
    Mounting EXPMEM Card
    NEAX2000 IVS2WCSSystemManual(PCS)
    ND-70920 (E), Issue 1.0Page 31
    MOUNTING EXPMEM CARD
    The EXPMEM (PZ-M537) card is required when the number of PS is more than
    128.
    (1) Confirm the correct switch settings. SeeCHAPTER 4
    (2) Mount the EXPMEM card on the MP card.
    For details, refer to the Installation Procedure Manual.
    (3) Then, mount the MP card into the MP slot of PIM0.ATTENTIONContents
    Static SensitiveHa ndl ing
    Prec au tio ns Requ ired 
    						
    							NEAX2000 IVS2WCS System Manual (PCS)Page 32ND-70920 (E), Issue 1.0
    CHAPTER 2 INSTALLATION
    Mounting CSH Card
    MOUNTING CSH CARD
    (1) Before mounting the CSH (PN-SC03-A) card, set the MB switch to UP
    position, and set the other switches to appropriate position.
    SeeCHAPTER 4.
    (2) Mount the CSH card in the AP slots of PIM0 through PIM7.
    PIM0-7: AP00-AP11 slots
    The AP11 slot on PIM0 is available only when the FP card is not mounted on the FP11 slot
    on PIM0.
    (3) After mounting the card, set the MB switch to DOWN position to put the card in service.ATTENTIONContents
    Static SensitiveHa ndl ing
    Prec au tio ns Requ ired 
    						
    All NEC manuals Comments (0)