    							CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-30DTC-A (DTI)
    NEAX2000 IVS2WCSSystemManual(PCS)
    ND-70920 (E), Issue 1.0Page 133
    SWITCH NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SW
    (Piano Key SW)
    1
    NOTE 3
    NOTE 4ONSource clock signal from network is
    sent to the PLO 0 input on MP card.
    OFFSource clock signal from network is
    not sent to the PLO 0 input on MP
    card
    2
    NOTE 3
    NOTE 4ONSource clock signal from network is
    sent to the PLO 1 input on MP card.
    OFFSource clock signal from network is
    not sent to the PLO 1 input on MP
    card.
    3ON Remote loop-back
    For normal operation
    4ON
    Local loop-back (AIS send)
    For normal operation
    5ONTransmission line cable:
    Coaxial cable (75 ohms)
    Transmission line cable:
    Twisted-pair cable (120 ohms)
    6
    Always set to OFF
    7
    8ON AP No. 04-15
    OFF AP No. 20-31
    OFF
    ON
    5 6 7 8
    1 2 3 4
    OFF
    OFF
    OFF
    OFF
    OFF 
    						
    							NEAX2000 IVS2WCS System Manual (PCS)Page 134ND-70920 (E), Issue 1.0
    CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-30DTC-A (DTI)
    The figure in the SWITCH NAME column and the position in in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and , the setting of the switch varies with the system concerned.
    NOTE 1:Set the groove on the switch to the desired position.
    NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/
    unplugging the circuit card.
    SWITCH NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    JPS
    (Jumper Pin)Balanced transmission
    (For twisted-pair cable)
    DOWNTA is grounded on the transmission
    line (For coaxial cable)
    JPR
    (Jumper Pin)
    Balanced transmission
    (For twisted-pair cable)
    DOWNRA is grounded on the transmission
    line (For coaxial cable)
    JP
    (Jumper Pin)
    RIGHTLine impedance: 75 ohms
    (For coaxial cable)
    Line impedance: 120 ohms
    (For twisted-pair cable)
    UP
    UP
    LEFT 
    						
    							CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-30DTC-A (DTI)
    NEAX2000 IVS2WCSSystemManual(PCS)
    ND-70920 (E), Issue 1.0Page 135
    NOTE 3:Set the SW-1 and SW-2 as follows:
    NOTE 4:When the PBX is a clock source office, set the SW-1 and SW-2 on all the DTI cards
    mountedinPIM0toOFF.
    NOTE 5:Mount the DTI card which receives a clock signal into PIM0. CONDITIONSDTI0 DTI1 DTI2 DTI3
    REMARKS
    SW
    -1SW
    -2SW
    -1SW
    -2SW
    -1SW
    -2SW
    -1SW
    -2
    When one DTI is
    provided.ONOFF––––––MP card will receive the clock
    signal from DTI0 at its PLO0
    input.
    When more than
    one DTI is
    provided.ON OFF OFF ON OFF OFF OFF OFFMP card will receive the clock
    signal from DTI0 at its PLO0
    input, under normal
    conditions.
    Should a clock failure occur
    with DTI0, MP card will
    automatically switch to the
    PLO1 input which gets from
    DTI1. 
    						
    							NEAX2000 IVS2WCS System Manual (PCS)Page 136ND-70920 (E), Issue 1.0
    CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-SC01 (DCH)
    PN-SC01 (DCH)
    Locations of Lamps, Switches, and Connectors
    Lamp Indications
    LAMP
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally.
    LC Green Remains lit when communications are normally ongoing with the
    D channel data links connected.
    LPB Green Not used
    SENS
    RUN
    MB
    SW0
    LC
    LPB SW1 
    						
    							CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-SC01 (DCH)
    NEAX2000 IVS2WCSSystemManual(PCS)
    ND-70920 (E), Issue 1.0Page 137
    Switch Settings
    SWITCH NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SENS
    (Rotary SW)
    NOTE 14-F Set the switch to match the AP Number (04-31) to
    be set by CM05.
    0-3 Not used
    MB (Toggle SW)
    NOTE 2
    UPFor make-busy
    For normal operation
    SW0
    (Piano Key SW)1 Always set to OFF
    2 Always set to OFF
    3 Always set to OFF
    4ON AP No. 04-15
    OFF AP No. 20-31
    F
    4
    AP No.SW0-4: ON
    04 05 06 07 08 09 10 11 12 13 14 15
    SW0-4: OFF
    20 21 22 23 24 25 26 27 28 29 30 31
    SW No.
    456789ABCDEF
    ON
    DOWN
    4
    3
    2
    1 OFF
    ON
    OFF
    OFF
    OFF 
    						
    							NEAX2000 IVS2WCS System Manual (PCS)Page 138ND-70920 (E), Issue 1.0
    CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-SC01 (DCH)
    The figure in the SWITCH NAME column and the position in in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and , the setting of the switch varies with the system concerned.
    NOTE 1:Set the groove on the switch to the desired position.
    NOTE 2:When the power is on flip the MB switch to ON (UP position) before plugging/
    unplugging the circuit card.
    SWITCH NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SW1 (DIP SW)
    1 Always set to OFF
    2 Always set to OFF
    3 Always set to OFF
    4 Always set to OFF
    5 Always set to OFF
    6 Always set to OFF
    7 Always set to OFF
    8 Always set to OFF
    12345678ON
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF 
    						