Mitel SX 200 ML PABX Instructions Guide
Have a look at the manual Mitel SX 200 ML PABX Instructions Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
General Description IMPORTANT SAFETY INSTRUCTIONS WARNING: Failure to follow all instructions may result in improper equipment opera- tion and/or the risk of electric shock. . This product is to be installed and serviced only by qualified personnel. . Read all instructions before attempting to install or use this product. l Install all assemblies using the procedures described in this Practice. l Configure this product with only the assemblies specified in this Practice. l Grounding circuit continuity is vital for safe operation of telecommunication equipment. Never operate telecommunication equipment with grounding conductor disconnected. Ensure grounding conductor is installed before connecting telecommunication cabling to any system (see Note). Note: It is recommended that all cabinets be unplugged from the ac mains during servicing. To reduce static susceptibility on a cabinet always attach the wrist strap from the cabinet being serviced, and immediately place any removed item into an antistatic bag. EXPLANATION OF USE FOR SYMBOLS AND NOTICES The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magni- DANGEROUS VOLTAGE tude to constitute a significant risk of electric shock to persons. A I The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (ser- l vicing) instructions in the literature accompanying the product. INSTRUCTIONS 0 I The ground symbol within a circle identifies the terminal which is intend- ed for connection to an external protective conductor. This connector PROTECTIVE GROUNDING TERMINAL must be connected to earth ground prior to making any other connec- tions to the equipment. d March 1997 Issue 1 Revision 0
General Description Danger indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. -Y Warning indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Caution indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury and/or damage to the equipment or property. : . . : Issue 1 Revision 0 March 1997
1. 2. 3. 4. 5. Table of Contents Introduction .................................................... ..1- 1 General .......................................................... ..l- 1 Reasonforlssue ................................................... ..l- 1 Disclaimer ........................................................ ..I- 1 System Overview.................................................2- 1 General .......................................................... ..2- 1 Physical Description ................................................. .2-l System Fail Transfer ................................................. .2-l Maintenance Connector .............................................. .2-l Physical Characteristics .............................................. .2-3 System Requirements ................................................ .2-3 Software Configurations and Supported Peripheral Devices ................... 2-3 SX-200@ ML LIGHTWARE 16TM Software .............................. .2-3 Voice Capabilities ................................................... .2-4 Data Capabilities .................................................... .2-5 Customer Data Entry (CDE) ........................................... .2-5 Hardware Overview. ............................................. .3-1 General .......................................................... ..3- 1 Sx-200 ML System Configuration ....................................... .3-l Peripheral Interface Cards ............................................. .3-l Universal Card ................................................... .3-2 Software Overview. .............................................. .4-1 General .......................................................... ..4- 1 PhysicalLayer ..................................................... ..4- 1 SchedulingLayer.....................................................4- 1 Communications Layer ............................................... .4-l MessageSubsystem ................................................ ..4- 1 Device Input/Output Layer ............................................. .4-2 UtilitiesLayer........................................................4- 2 Main Control Processor Applications Software ............................. .4-2 Peripheral Control Processor Software ................................... .4-2 Database.. ................................ ..~......................4- 2 Maintenance......................................................5- 1 General .......................................................... ..5- 1 Maintenance Objectives .............................................. .5-l N-232 Maintenance Terminal .......................................... 5-l Diagnostic Log Files ................................................. .5-l Typesof Diagnostics ................................................ ..5- 2 Database Installation and Updates ....................................... 5-2 March 1997 Issue 1 Revision 0 V
General Description List of Figures Figure 2-l SX-200 ML Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2 List of Tables Table 2-l Physical Characteristics ..................................... .2-2 Table 2-2 Environmental Requirements ................................. .2-3 Table 2-3 Electrical Requirements ...................................... .2-3 vi Issue 1 Revision 0 March 1997
1 Introduction General This practice provides an overview of hardware features, as well as a summary of environmental, electrical, and maintenance considerations for the SX-200@ ML PABX. Refer to the following sections for more detailed descriptions of related information: l Features Description Practice l Engineering information Practice l installation information Practice Reason for Issue This issue describes the SX-200 ML LIGHTWARETM 16 software variant. Disclaimer The following products have been manufacture discontinued by Mitel. These products are supported but not described in SX-200 ML Practices: l SUPERSET 3T~ and SUPERSET 4@ telephone sets l SUPERSET ~DNTM and SUPERSET 4DNTM telephone sets l DATASET 1101 data cartridge l SUPERSET’” DSS module. The following products and peripheral devices are not supported on the SX-200 ML PABX and are not described in SX-200 ML Practices: l Modem Interconnect Panel l DATASET 1102 Rack-mounted Dataset l DATASET 2102 Rack-mounted Dataset l DATACABINET 9000 data cabinet l DATASHELF 9100 datashelf l ISDN Node . Fiber Interface Module (and associated products) l Peripheral Node l LCD Console (and Console module for Universal Card). March 1997 Issue 1 Revision 0 l-l
General Description l-2 Issue 1 Revision 0 March 1997
2 System Overview General The SX-200 ML PABX is a microprocessor-controlled telephone system that handles both voice and data switching. The system hardware is electrically compatible with most: 9 single line telephones, l MITEL@proprietary sets, l key telephone systems, l PABX telephone systems, and l central office exchanges. The following subsections outline the hardware configuration and the software version. Refer to Section 3 of this practice for additional information about the system hardware, and to Section 4 for an overview of the software structure. Table 2-l describes physical characteristics of the PABX. Figure 2-l shows the SX-200 ML PABX. Physical Description The system cabinet has a steel frame and is approximately 22.9 cm wide x 48 cm’high x 42.0 cm deep (9 inches x 19 inches x 16.5 inches). The internal structure of the cabinet is designed to hold the system cards and components. The front panel is plastic and can be removed with a screwdriver, allowing access to the cards. The cabinet holds one Main Control Card II (MCC II), one Bay Control Card, one Bay Power Supply, and up to eight Peripheral Interface Cards. Located on the rear of the cabinet is a connector panel for printer and maintenance ports, and the SFT (system fail transfer) control port. The system consists of one cabinet providing up to 96 ports. System Fail Transfer System Fail Transfer (SFT) (or power fail transfer) is provided by the SFT control port, allowing preselected DTMF or rotary telephones to be connected directly to CO trunks in the event of system failure in the PABX. To provide system fail transfer, a SFT unit must be connected to the system. Maintenance Connector 2.1 A connector for a remote maintenance terminal is provided on the rear panel of the cabinet. March 1997 Issue 1 Revision 0 2-1
General Description FRONT PANEL 4 / FRONT VIEW - _ (PANEL REMOVED) k POWER SUPPLY PERIPHERAL 1 INTERFACE CARD 1 BAY CONTROL CARD 1 MAIN CONTROL1 t TI ADAPTER ASSEMBLY 25-PAIR AMPHENOL CONNECTOR GROUND I PORT FOR SYSTEM FAIL TRANSFER UNIT CC0560 Figure 2-I SX-200 ML Cabinet 2-2 issue 1 Revision 0 March 1997
System Overview Physical Characteristics Table 2-1 Physical Characteristics Cabinet Height 48.0 cm Cabinet Width 22.9 cm Cabinet Depth 42.0 cm Cabinet Weight (cards installed) 19 kg 19.0 inches 9.0 inches 16.5 inches 42 pounds System Requirements Environmental and electrical requirements for the PABX are shown in Table 2-2 and Table 2-3 respectively. Table 2-2 Environmental Requirements Operating Temperature 0 to 4o” c 32 to 104’ F Storage Temperature -20 to 5o” c -4 to 122’ F Relative Humidity (Operating) (non-condensing) 20 to 80% 20 to 80% Relative Humidity (Storage) (non-condensing) 10 to 90% 10 to 90% Table 2-3 Electrical Requirements AC Input Voltage 102 - 135 Vat (115 v - 9109-008-OOO-SA) AC Input Frequency 47-63 Hz AC Input Power 125 Watts RMS for each cabinet DC Output Power 100 Watts for each bay Reserve Power Uninterruptable Power Supply Software Configurations and Supported Peripheral Devices SX-200 ML LIGHTWARE 16 Software Each SX-200 ML LlGHTWARE 16 software package includes all features and is ac- companied with a System ID module, which is plugged into the Main Control Card II to enable operation. The SX-200 ML LlGHTWARE 16 optional features are enabled by a password and include: l MITEL Telephony Applications Intetiace Package (includes MiTAITM) l Data communication features r March 1997 Issue 1 Revision 0 2-3
General Description 9 Hotel/Motel . Property Management System l Automated Attendant, and . Automatic Call Distribution. Voice Capabilities The SX-200 ML PABX interfaces to analog and digital peripheral devices using stan- dard twisted-pair office wiring. Peripheral devices include, but are not limited to, the following: Standard Telephones: Industry-standard rotary dial and DTMF telephones are sup- ported; ONS and OPS lines provide an interface for these sets. SUPERSET 401+‘~ Telephone: The SU/?ERSET407+ telephone is a single-line dig- ital telephone. It has a Trans/Conf key, a Message key, a Hold/Retrieve key, and six Speed Dial keys, a hold lamp and a message indicator lamp, as well as keys for adjusting the ringer and handset receiver volume. SUPERSET 410’~ Telephone: The SUPERSET 4 10 telephone is a multi-line digital telephone. In addition to its1 0 fixed function keys, the SUPERSET has 6 keys that can be programmed as Speed Call keys, Feature Access keys or Line Appearances. The set also has a Message key and Microphone key with indicator lamps. Up to three MILINKT~ Data Modules can be connected to this set to provide an interface for a data device. SUPERSET 420TM Telephone: The SUPERSET 420 is a multi-line digital telephone. It has 12 programmable keys with associated LCD indicators. These keys can be programmed as Speed Call keys, Feature Access keys or Line Appearances. Directly below the 12 programmable keys is a 2x16 alphanumeric bitmap graphics display and three softkeys. The three softkeys allow set users to select command prompts that appear in the display. The set also has a Message key and Microphone key with indicator lamps, and eight fixed function keys without indicator lamps. Up to three M/LINK Data Modules can be connected to this set to provide an interface for a data device. SUPERSET 430TM Telephone: The SUPERSET 430 telephone is a multi-line digital telephone that provides advanced telephony features. The SUPERSET 430 has1 2 keys that can be programmed as Speed Call keys or Line Appearances. An alphanu- meric bitmap graphics display and six softkeys allow users to select call handling features easily. Up to three M/L/NK Data Modules can be connected to this set to provide an interface for a data device. Attendant Console: The SUPERCONSOLE 1000TM and SUPERSET 7000TM Attendant consoles interface by one pair wiring to a DNIC circuit on a Digital Line Card. Programmable Key Module: The Programmable Key Module (PKM) provides 30 additional keys and line status displays to a SUPERSET 470, SUPERSET 420, or SUPERSET 430 telephone. Flash rates for the PKM indicators are the same as on its associated telephone. 2-4 Issue 1 Revision 0 March 1997