Page 441

Customer Data Entry (CDE)
4.113 Commands
1 -UNLIMITED:Pressing the UNLIMITED softkey enters the default
value of unlimited in the Maximum Number of Dialed Digits field. If the
cursor is positioned at the default value, “Unlimited” is not displayed.4-TOP: This 
softkey positions the line pointer to the first line of the
form. The command line displays the first line.5-BOTTOM: Pressing the 
BOTTOM softkey positions the line pointer
to the last line of the form. The command line displays this line.6-QUIT:...

Page 442

SECTION MITL9109-094-210-NAForm 28 
-Form Access Restriction Definition
4.114 This form specifies the level of access for Forms 01 to 44.
There are five levels of access; the installer level has the high-
est degree of access and the Attendant has the lowest. Each form is
defined as Read Only, Read/Write or No Access. When the system is
first initialized, the Installer and MAINTI level have a Read/Write ac-
cess for each form; the rest of the levels default to No Access. Note
that at each level of access...

Page 443

Customer Data Entry (CDE)
4.115 Field Description
FORM NAME: This field lists all the form numbers and names of theCDE package. The FORM NAME field cannot be modified.INST, 
MAINTl, MAINT2, SUPER and ATT: These fields represent the
five levels of access and list the access type (Read Only, Read/Write or
No Access) for each form. Note that the selected level of access is not
displayed on the softkeys. The 
INST field cannot be modified.4.116 Commands
l-READ ONLY: Pressing the READ ONLY 
softkey restricts...

Page 444

SECTION MITL9199-094-210-NAENTER 
XXXXXXXX OLD PASSWORD:, whereXXXXXXXX is the selected
level of access.
O-FORM NUM: This 
softkey selects a form by number. Pressing the
FORM NUM 
softkey displays the ENTER FORM NUMBER: prompt on the
command line. The selection is completed by entering a valid form
number (1 to 35).
O-ENTER: This 
softkey appears only after data for an entry number
has been modified. Pressing the ENTER 
sof-tkey commits each modi-
fication one at a time to the database.
1...

Page 445

Customer Data Entry (CDE)
Form 29 -DTE Profile
4.117 In order for the Data transceiver (DTRX) to communicate with
the attached data terminal equipment (DTE), it is necessary to
specify the programmable options which define the characteristics ofthe terminal. The Data transceiver circuit provides data devices with
the ability to dial a destination via a keyboard. The 
DIE profile form
provides 25 programmable profiles.TABLE 4-44
FORM 29 
- DATA TERMINAL EQUIPMENT PROFILE
CDE TERMINAL DISPLAY
12:lO PM...

Page 446

SECTION MITL9109-094~Zl O-NA5-BOTTOM: Pressing the BOTTOM 
softkey moves the line pointer to
the last line of the form. The command line displays this line.
6-QUIT: Pressing the QUIT 
softkey when editing this form returns the
display to the level before the field was modified. The change is not
saved. At all other times, pressing this 
softkey exits Form 29 and
returns the display to the level where the forms are selected. Refer to
Table 4-2, Available Forms.
6-CANCEL: This 
softkey appears after a...

Page 447

Customer Data Entry (CDE)
Options For Form 29
4.120 The system displays this form when the programmer presses
the SEL. OPTION softkey in Form 29, Data Terminal Equipment
Profile. The options displayed are for the Profile Number that was on
the command line of Form 29.TABLE 4-45
12:lO PM 15-JAN-88OPTIONS FOR FORM 29
CDE TERMINAL DISPLAY
alarm status = NO ALARM
IPROFI LE NL&lBER : 1JVALUE
Termi na I TypeVIDEO TERM
LanguageENSLISHDTRX Echop I exDISABLED
EditingDISABLED
Editing character delete (0 
-127,...

Page 448

SECTION MITL9109-094-210-NAdisplay to the level before the field was modified. The change is not
saved. At all other times, pressing this 
softkey exits Options for Form
29 and returns the display to Form 29.4.123 Options Description
Terminal Type: This parameter is used to determine how the delete
character is defined on a video or teleprinter terminal. A teleprinter
terminal displays a 
“I when the delete character is used and the video
terminal transmits a , , .
Language: Commands and responses for...

Page 449

Customer Data Entry (CDE)
the DPABX that have a  will have a  injected. Thisdoes not include  which are echoed back to the DTE. Thisoption would be used if the DTE provided local echoing of
characters transmitted.
4.ALWAYSThe 
 will be injected if the  is originated from the
DTE or DTRX.*Number of Pads after : This field is used for terminals that
require delays after a carriage return before receiving printable char-
acters (printers with small or no buffers). Values entered range from 0
to 7. This...

Page 450

SECTION MITL9109-094-210-NAReview List for Form 29
4.124 This form appears when the REVIEW 
softkey is pressed in Form
29, DTE Profile. The form provides a list of users of a particular
profile identified by their physical location. Refer to Table 4-46, Review
for Form 29.
TABLE 4-46
12:15 PM 15-JAN-88REVIEW LIST FOR FORM 29
CDE TERMINAL DISPLAY
alarm status = NO ALARM
[ PROFILE NUdBER : 1 IBAYSLT CCT SCTCOMMENTS
242
24
:2
I4 44 3:
,-
i-QUIT
24122-3-4-5-
7-PROFILENlbl8-9-O-ATTENDANT CONSOLE DISPLAY
[...