Page 391

Customer Data Entry (CDE)Dataset. Because the DATASET 1102 is a dual DATASET, a second line
appears for subcircuit 2 of the port.
3-DSI 102 CCTP:This softkey appears after the DATA DEV TYPE
softkey has been pressed on the second line of a port assigned as a
DATASET 1102. It is the only softkey available in this situation. Press-
ing the DS1102 CCT2 
softkey assigns the device type for subcircuit 2
of the port as an Asynchronous Rack Mount 
Dataset.
4-DSllOl: This softkey appears after the DATA DEV TYPE...

Page 392

SECTION MITL9109-094~Zl O-NA8-DELETE: This 
softkey appears when the cursor is positioned at data
on the command line. Pressing the DELETE 
softkey removes the entry
from the form. The deletion is completed by pressing the 
softkey:
ENTER.O-DELETE FIELD: This 
softkey appears when the cursor is positioned
in the AVL or HOTLINE field, when a value has been already pro-
grammed. Pressing the DELETE FIELD 
softkey removes the value which
is programmed in that field. The deletion is completed by pressing...

Page 393

Customer Data Entry (CDE)
Form 13 - Trunk Circuit Descriptors
4.60Trunk circuit descriptors are similar to Classes of Service. A
trunk circuit descriptor specifies the hardware options for eachtype of Trunk Card. Refer to Table 4-23, Trunk Circuit Descriptors for
the form layout. Trunk circuit descriptors are complemented by the
switch settings on the SX-200 type Trunk Cards. Refer to the Trunk
Card Switch Assignments Forms in Part Number 
9109-094-206-NA,
Installation Forms. There are 12 Trunk Card...

Page 394

SECTION MITLSI 09-094~Zl O-NATRUNK TYPE: This field lists one of eight trunk types for each trunk
circuit descriptor. Note that the selected trunk type (the one that
appears on the command line) is not displayed on the softkeys.
NUMBER OF TRKS ASSIGNED: This field records the number of trunks
which use each trunk circuit descriptor. The trunk circuit descriptor
can be assigned a 
new trunk type only if this field is zero. To clear the
NUMBER OF TRKS ASSIGNED field, the trunks must first be deassigned....

Page 395

Customer Data Entry (CDE)
3-E&M MODULE: Pressing this softkey programs the selected trunk
circuit descriptor as an E&M Trunk Module. Pressing the ENTER 
softkeycompletes the selection and the TYPE field displays the E&M MODULE
prompt.
3-E&M TRUNK: This 
softkey appears when the MORE softkey has
been pressed. Pressing this 
softkey programs the selected trunk circuit
descriptor as an E&M Trunk Card. Pressing the ENTER 
softkey com-
pletes the selection and the TYPE field displays the E&M CARD prompt.
3-Tl...

Page 396

SECTION MITLSI 09-094-ZIO-NA
curred. Pressing the CANCEL softkey returns the display to the level
where the programming error occurred. The CANCEL 
softkey appears
with an error message.
7-DESC NUM:Pressing this 
softkey displays ENTER DESC NUM:
prompt. This 
soltkey selects a trunk circuit descriptor number. The
selection is completed by entering a valid number (1 to 25).
8-SEL. OPTIONS: Pressing the SEL. OPTIONS 
softkey displays a new
form. This form displays the options (parameters) associated with...

Page 397

Customer Data Entry (CDE)
Options for Trunk Circuit Descriptors
4.63 This form appears only when the SEL. OPTIONS softkey is
pressed (refer to Table 4-23, Trunk Circuit Descriptors). This
form displays the options (parameters) associated with each trunk type
assigned to each trunk circuit descriptor. Refer to Table 4-24, Trunk
Circuit Descriptor Options.
TABLE 4-24
TRUNK CIRCUIT DESCRIPTOR OPTIONS FOR FORM 13
CDE TERMINAL DISPLAY
4:26 PM 15-JAN-88alarm status = NO ALARM
I4CCTCOTRU’JK: 2I OPTION NAME...

Page 398

SECTION MITL9109-094-210-NAdisplay to the level before the field was modified. The change is not
saved. The following warning prompt appears on the command line:
DATA HAS BEEN CHANGED BUT NOT YET SAVED IN DATABASE --
“ENTER” TO SAVE. At all other times, pressing this softkey returns the
display to the point where the SEL. OPTION 
softkey was pressed.6-CANCEL: This 
softkey appears after a programming error has oc-
curred. Pressing the CANCEL 
softkey returns the display to the level
where the programming...

Page 399

Customer Data Entry (CDE)
TABLE 4-25 (CONT’D)TRUNK HARDWARE OPTIONS
Type :E&M 
M(WXILE and E&M MCDJLE DI SA
Reverse to Idle
Far-End Gives Answer Supervision
Inhibit Automatic Supervision
No Seize Alarm
No Release Alarm
Toll Office
Is this a CC
Dl%lFImpedance ** Use Module Dip Switches to Program ** (600 Ohms or (Complex)
E Lead Invert
M Lead Invert 
** required for type 5 operation **Disconnect Timer (150 4 300 msl(50 ms increments)
Release Acknowledge Timer (2000 + 9900 ms)(100 ms inc)
Guard Timer (200...

Page 400

SECTION MITL9109-094-210-NATABLE 4-25 (CONT’D)
TRUNK HARDWARE OPTIONS
6-CCT DID (CCM’D)No Seize Alarm
No Release Alarm
Toll Office
Is this a- CD
DTMFImpedance (600 Ohms or Complex)
Disconnect Timer (150 
-) 300 ms)(50 ms increments)
Release Acknowledge Timer (2000 -+ 9900 ms)(100 ms inc)
Guard Timer (200 -+ 1000 ms)(100 ms increments)
Start Type (Inmed)Debounce Timer (20 --) 150 ms) (10 ms increments)
Wink Timer (150 --( 300 ms) (50 ms increments)
Remote End is a Satellite
Remote End is a Satellite with...