Page 391
Customer Data Entry (CDE)Dataset. Because the DATASET 1102 is a dual DATASET, a second line appears for subcircuit 2 of the port. 3-DSI 102 CCTP:This softkey appears after the DATA DEV TYPE softkey has been pressed on the second line of a port assigned as a DATASET 1102. It is the only softkey available in this situation. Press- ing the DS1102 CCT2 softkey assigns the device type for subcircuit 2 of the port as an Asynchronous Rack Mount Dataset. 4-DSllOl: This softkey appears after the DATA DEV TYPE...
Page 392
SECTION MITL9109-094~Zl O-NA8-DELETE: This softkey appears when the cursor is positioned at data on the command line. Pressing the DELETE softkey removes the entry from the form. The deletion is completed by pressing the softkey: ENTER.O-DELETE FIELD: This softkey appears when the cursor is positioned in the AVL or HOTLINE field, when a value has been already pro- grammed. Pressing the DELETE FIELD softkey removes the value which is programmed in that field. The deletion is completed by pressing...
Page 393
Customer Data Entry (CDE) Form 13 - Trunk Circuit Descriptors 4.60Trunk circuit descriptors are similar to Classes of Service. A trunk circuit descriptor specifies the hardware options for eachtype of Trunk Card. Refer to Table 4-23, Trunk Circuit Descriptors for the form layout. Trunk circuit descriptors are complemented by the switch settings on the SX-200 type Trunk Cards. Refer to the Trunk Card Switch Assignments Forms in Part Number 9109-094-206-NA, Installation Forms. There are 12 Trunk Card...
Page 394
SECTION MITLSI 09-094~Zl O-NATRUNK TYPE: This field lists one of eight trunk types for each trunk circuit descriptor. Note that the selected trunk type (the one that appears on the command line) is not displayed on the softkeys. NUMBER OF TRKS ASSIGNED: This field records the number of trunks which use each trunk circuit descriptor. The trunk circuit descriptor can be assigned a new trunk type only if this field is zero. To clear the NUMBER OF TRKS ASSIGNED field, the trunks must first be deassigned....
Page 395
Customer Data Entry (CDE) 3-E&M MODULE: Pressing this softkey programs the selected trunk circuit descriptor as an E&M Trunk Module. Pressing the ENTER softkeycompletes the selection and the TYPE field displays the E&M MODULE prompt. 3-E&M TRUNK: This softkey appears when the MORE softkey has been pressed. Pressing this softkey programs the selected trunk circuit descriptor as an E&M Trunk Card. Pressing the ENTER softkey com- pletes the selection and the TYPE field displays the E&M CARD prompt. 3-Tl...
Page 396
SECTION MITLSI 09-094-ZIO-NA curred. Pressing the CANCEL softkey returns the display to the level where the programming error occurred. The CANCEL softkey appears with an error message. 7-DESC NUM:Pressing this softkey displays ENTER DESC NUM: prompt. This soltkey selects a trunk circuit descriptor number. The selection is completed by entering a valid number (1 to 25). 8-SEL. OPTIONS: Pressing the SEL. OPTIONS softkey displays a new form. This form displays the options (parameters) associated with...
Page 397
Customer Data Entry (CDE) Options for Trunk Circuit Descriptors 4.63 This form appears only when the SEL. OPTIONS softkey is pressed (refer to Table 4-23, Trunk Circuit Descriptors). This form displays the options (parameters) associated with each trunk type assigned to each trunk circuit descriptor. Refer to Table 4-24, Trunk Circuit Descriptor Options. TABLE 4-24 TRUNK CIRCUIT DESCRIPTOR OPTIONS FOR FORM 13 CDE TERMINAL DISPLAY 4:26 PM 15-JAN-88alarm status = NO ALARM I4CCTCOTRU’JK: 2I OPTION NAME...
Page 398
SECTION MITL9109-094-210-NAdisplay to the level before the field was modified. The change is not saved. The following warning prompt appears on the command line: DATA HAS BEEN CHANGED BUT NOT YET SAVED IN DATABASE -- “ENTER” TO SAVE. At all other times, pressing this softkey returns the display to the point where the SEL. OPTION softkey was pressed.6-CANCEL: This softkey appears after a programming error has oc- curred. Pressing the CANCEL softkey returns the display to the level where the programming...
Page 399
Customer Data Entry (CDE) TABLE 4-25 (CONT’D)TRUNK HARDWARE OPTIONS Type :E&M M(WXILE and E&M MCDJLE DI SA Reverse to Idle Far-End Gives Answer Supervision Inhibit Automatic Supervision No Seize Alarm No Release Alarm Toll Office Is this a CC Dl%lFImpedance ** Use Module Dip Switches to Program ** (600 Ohms or (Complex) E Lead Invert M Lead Invert ** required for type 5 operation **Disconnect Timer (150 4 300 msl(50 ms increments) Release Acknowledge Timer (2000 + 9900 ms)(100 ms inc) Guard Timer (200...
Page 400
SECTION MITL9109-094-210-NATABLE 4-25 (CONT’D) TRUNK HARDWARE OPTIONS 6-CCT DID (CCM’D)No Seize Alarm No Release Alarm Toll Office Is this a- CD DTMFImpedance (600 Ohms or Complex) Disconnect Timer (150 -) 300 ms)(50 ms increments) Release Acknowledge Timer (2000 -+ 9900 ms)(100 ms inc) Guard Timer (200 -+ 1000 ms)(100 ms increments) Start Type (Inmed)Debounce Timer (20 --) 150 ms) (10 ms increments) Wink Timer (150 --( 300 ms) (50 ms increments) Remote End is a Satellite Remote End is a Satellite with...