Page 361

Customer Data Entry (CDE)
Form 08 - Console LDN Assignments
4.33This form specifies the LDN assignments for the consoles (referto Table 4-13, Attendant LDN Assignments). A maximum of nine
LDN assignments can be programmed for each Attendant Console. Theattendant 
LDNs are assigned to the softkeys. Console softkey 1 is
reserved for the RECALL function. Each LDN assignment is identified bya directory number. The directory numbers are subject to the same
constraints as all Listed Directory Numbers (i.e.,...

Page 362

SECTION MITL9109-094-210-NA
only appear once per console. If it is required that two consoles share
the same LDN, then both consoles must be in the same Tenant Group.LABEL:This field specifies the actual text that the console LCD
displays as 
softkey prompts. The LABEL field provides for a maximum
of 12 characters. The label for console 
softkey 1 defaults to RECALL
and cannot be modified. The label for console 
softkey 2 defaults to
INTERNAL. 
Softkey 2 is shared between the extension number pro-...

Page 363

Customer Data Entry (CDE)
or by positioning the line pointer at the selected LDN key.g-NEXT:Pressing the NEXT softkey displays the physical location
(bay, slot and circuit numbers) of the next programmed Attendant
Console. If the physical location of the last programmed console is
displayed, then pressing this 
softkey again displays the bay, slot and
circuit numbers of the first programmed console.
O-ENTER: This 
softkey appears only after data for an entry has been
modified. Pressing the ENTER 
softkey...

Page 364

SECTION MITL9109-094-210-NAForm 09 
- Stations/SUPERSET Telephones
4.36 This form assigns stations and SUPERSEJ telephones to the
system. Refer to Table 4-14, StatiodSUPERSEJ Telephones.TABLE 4-14
FORM 09 
- STATION/SUPE:‘RSET TELEPHONES
CDE TERMINAL DISPLAY
IO:15 PM5-JAN-88
ccr
011021031041051
x;1 1
8L:I 1021xi1 1
EXTN
311
312
313
314
315
316
317
318
301
302
303
304
311cos COR TYP
1 1Set
1 1Set
1 1Set
1 1Set
1 1
Set
~1 1Set
:1Set
Set
1?IStn1: 1Stn
Stn
1 1
Stn
-rPalarm status 
= NO ALARM
fdNOU\ICE NAME-...

Page 365

Customer Data Entry (CDE)
prompt. When a physical location (Bay, Slot and Circuit) is defined as a
Call Announce Port, this field displays the CAP prompt. The Call An-
nounce Port can be a Station Circuit, a SUPERSET Telephone Circuit, a
COV Circuit or OPS Circuit. Hardware restrictions prevent an ONS
Circuit from being a Call Announce Port and only a 
SUPERSET tele-
phone can OWN one. Note that this field cannot be modified; it is
generated by the system based on what was entered in the PRO-
GRAMMED...

Page 366

SECTION MITL9109-094~Zl O-NAGroup, Extension Number, COS and COR for the first device, if this has
not been done already. Press the ENTER 
softkey. The system automati-
cally assigns incremented extension numbers, the same COS, COR and
Tenant Group numbers to the rest of the devices in the block.
6-QUIT: Pressing the QUIT softkey when editing this form returns the
display to the level before the field was modified. The change is not
saved. At all other times, pressing this 
softkey exits Form 09 and...

Page 367

Customer Data Entry (CDE)d
SUPERSET Telephone Lines
4.39This form appears when the EXPAND SET softkey is pressed in
the 
StatiorVSlJPERSET Telephones form. It is used to program
SUPERSET telephone line appearances and feature keys. Refer to Table
4-l 5, 
SUPERSET Telephone Lines for the Yorm layout.TABLE 4-15
SUPERSET TELEPHONE LINES
CDE TERMINAL DISPLAY
IO:15 PM 15-JAN-88alarm status = NO ALARM
KEYTYPEDIRECTIONRINGSECRETARIALEXT NW TRUUK NCMBER
x:PrimeI n/Outlmned No2110
MultipleI n/OutDelay No2111...

Page 368

SECTION MITLSI 09-094-210-NAEXT NUM: This field contains the extension number of the line, This
applies to the Prime Line, Key lines, Multiple Call lines or Personal
Outgoing lines. When this field is filled for a specific key, no entry is
allowed in the corresponding TRUNK NUMBER field. The EXT NUM field
is blank if the 
SUPERSET key directly selects a trunk.
TRUNK NUMBER: If the 
SUPERSET key is assigned as DTS or Private
Trunk, this field contains the trunk number. Trunk numbers are defined
in Form...

Page 369

Customer Data Entry (CDE)
MORE **softkey again returns the display to the first set of feature
keys. Press the desired 
softkey followed by the ENTER softkey to
assign that particular feature to the 
SUPERSET key displayed on the
command line. The selected feature appears in the TYPE field.
Figure 4-8 Programmable Feature Keys for Digital Sets
1 -CALL FORWARDP-CALL PICKUP3-NIGHT ANSWER4-CALLBACK5-*” MORE **
6-QUIT7-SWAP8-CALL/Al-rNg-DATA DISCO-Figure 4-9 More Programmable Feature Keys for Digital Sets...

Page 370

SECTION MITL9109-094-210-NAprogrammed appearances of the selected Line Select key on all sta-
tions and 
SUPERSET telephones.
O-ENTER: This 
softkey appears only after data for an entry has been
modified. Pressing the ENTER 
softkey commits the Line Select Key
information in the database.
Directional Variants: When the cursor is at the DIRECTION field on
the command line, the 
softkeys display the directional variants (refer to
Figure4-10,DirectionalVariants).Refer toSection
MITLSIOS-094-105-NA, Features...