Customer Data Entry (CDE) Form 24 - ARS: Route Lists 4.99This form specifies the order that the Route numbers are se- lected. There are 100 Route List numbers; each Route List num-ber accommodates a maximum of six Route numbers. Refer to Table 4-38, ARS: Route Lists for the form layout.TABLE 4-38 FORM 24 - ARS: ROUTE LISTS CDE TERMINAL DISPLAY 7:50 AM 15-JAN-88 alarm status = NO ALARM LIST NLhlFIRST SECOND WI-TI-IIFD WI- FOURTH WTFlFiH Wl SIXTH W-l 0192ON 8:3 8:06 07 8:101112 0132 ON...
Page 432
SECTION MITL9109-094-210-NA4.101 Commands 4-TOP: Pressing the TOP softkey moves the line pointer to the first line of the form. The command line displays the first line. 5-BOTTOM: Pressing the BOTTOM softkey moves the line pointer to the last line of the form. The command line displays this line. 6-QUIT: Pressing the QUIT sof-tkey when editing this form returns the display to the level before the field was modified. The change is not saved. At all other times, pressing this softkey exits Form 24 and...
Page 433
Customer Data Entry (CDE) Form 25 - ARS: Route Plans 4.102 This form assigns the Route Lists to the time and day zones. There are 18 time zones (six for each day zone). Each time zone has a start time that can be set by the installer. The last specified start time creates a time period from its start time to the first specified start time of that day zone. If a time zone has no assigned Route List number, then all calls during that time period are restricted from this Route Plan. There are a maximum of...
Page 434
SECTION MITL9109-094-210-NA4.104 Commands 6-QUIT: Pressing the QUIT softkey when editing this form returns the display to the level before the field was modified. The change is not saved. At all other times, pressing this softkey exits Form 25 and returns the display to the level where the forms are selected. Refer to Table 4-2, Available Forms. B-CANCEL: This softkey appears after a programming error has oc- curred. Pressing the CANCEL softkey returns the display to the level where the programming...
Page 435
Customer Data Entry (CDE) Form 26 - ARS: Digit Strings 4.105 This form (and its nested form) link the digits dialed by the user to the appropriate Route, Route List or Route Plan. It selects therelevant Route (if there is only one route), or Route List (if there is more than one route and the time of day is not important), or Route Plan (if the choice of routes vary with the time of day) by the user-dialed digits. Refer to Table 4-40, ARS: Digit Strings for the form layout. Refer to Section...
Page 436
SECTION MITL9109-094-210-NAcannot dial the specified leading digit(s). If this field is left blank, then every COR Group can access the specified leading digit(s). 4.107 Commands 1 -YES/NO:This softkey has two functions; it enables or disables system dial tone for each entry. Pressing the YES softl.ey enables the system dial tone when that leading digit is accessed. The RETURN DIAL TONE field displays YES and the softkey now displays NO . Pressing the NO softkey disables the system dial tone when...
Page 437
Customer Data Entry (CDE) Form 26 - ARS: Nested Digit Strings 4.108 This form is reserved for specifying subsequent digits for eachentry in the LEADING DIGITS field of the previous form. It can only be accessed from the previous form. Refer to Table 4-41, ARS: Nested Digit Strings for the form layout. Refer to Section MITL9109-094-220-NA, Automatic Route Selection and Toll Control for details.TABLE 4-41 ARS: NESTED DIGIT STRINGS CDE TERMINAL DISPLAY 7:50 AM 15-JAN-88alarm status = NO ALARM DIGITS TO BE...
Page 438
SECTION MITLSI 09-094-210-NAexpects an account code for that digit string entry from users with COS Option 201 (Account Code, Forced Entry - Long Distance Calls) enabled. Default condition is NO. TERM TYPE AND NUM: This field specifies where the digit string terminates. If there is only one route, then ROUTE is selected. If there is more than one route, but the time of day is not important, then LIST is selected. If the choice of routes vary with the time of day, then PLAN is selected. 4.110 Commands...
Page 439
Customer Data Entry (CDEY 6-QUIT: Pressing the QUIT softkey when editing this form returns the display to the level before the field was modified. The change is not saved. At all other times, pressing this softkey returns the display to the previous form at the entry where the SHOW STRINGS softkey was pressed.6-CANCEL: This softkey appears after a programming error has oc- curred. Pressing the CANCEL softkey returns the display to the level where the programming error occurred. This softkey appears...
Page 440
SECTION MITL9109-094-210-NAForm 27 - ARS: Maximum Dialed Digits 4.111 This form specifies the maximum number of dialed digits al- lowed for each Class of Restriction. The purpose of this form is to accommodate countries with open numbering plans such as Malay-sia, where it is generally not possible to determine from the leading digits the number of digits to follow. NOTE for North America the specified default value of Unlimited applies. Refer to Section MITL9109-094-220-NA (ARS), for detailed...