Page 491
Customer Data Entry (CDE) 4.177 Commands 6-QUIT: Pressing the QUIT softkey exits from the form. 8-SEL. OPTION: Pressing the SELECT OPTION softkey displays the Link Descriptor Options subform for the descriptor on the command line. O-REVIEW:Pressing the REVIEW softkey displays the Review List subform for the descriptor on the command line. Page 169
Page 492
SECTION MITL9109-094-210-NALink Descriptor Options for Form 42 TABLE 4-64 LINK DESCRIPTOR OPTIONS FOR FORM 42 CDE TERMINAL DISPLAY ‘II :Ol PM 15-JAN-88alarm status = NO ALAIW ‘[ LINK DESCRIPTOR NWIBER : 11IN/CUT GOINGAlarm debounce timer(300 - 3200 ms)B8ZS zero code suppression Slip rate - maintenance limit( 0 - 9000 ) /24 hrs Slip rate - service limit( 0 - 9000 ) /24 hrs Slip rate - network sync limit( 0 - 9000 ) /24 hrs BER - maintenance limit(IO**-n , n = ( 3,4,5,6 )I / hour BER - service...
Page 493
Customer Data Entry (CDE) 8-CONFIRM: This softkey appears when an option value has been changed. Press the CONFIRM softkey to enter the change in the data- base. O-ENTER:Pressing the ENTER softkey (or the RETURN key on a terminal) stores the changed parameter in the database. 4.180 Option Descriptions Alarm Debounce Timer The Alarm Debounce Timer defines the length of time a fault condition must be present before it is reported to the main controller. The range of the timer is 300 to 3200 ms. The...
Page 494
SECTION MITL9109-094-210-NAFraming Loss Limits Framing loss occurs when the digital trunk cannot find the proper framing bit sequence in the incoming bit stream. It is thus unable to ensure correct decoding of the channels. There are 2 framing loss limits maintenance and service. The framing loss error rate is between 0 and 9000 losses over a 24 hour period.Limit Definitions Maintenance:When a maintenance limit is exceeded, the system generates a maintenance log. Service:When a service limit is exceeded,...
Page 495
Customer Data Entry (CDE) Review List for Form 42 4.181 The review form provides a list of users for each descriptor,identified by their physical location. There are no fields that the programmer can edit.TABLE 4-65 II:01 PM 15-JAN-88REVIEW LIST FOR FORM 42 CDE TERMINAL DISPLAY alarm status = NO ALARM: LINK DESC NO: 011BAYSLOTCOMMENTS2-3- 4-5- i-WIT7-8-9-O-ENTER ATTENDANT CONSOLE DISPLAY 4.182 Field Description: The header line identifies the link descriptor being reviewed.BAY, SLOT: These fields list...
Page 496
SECTION MITL9109-094-210-NAForm 43 - Tl Link Assignment 4.183 This form assigns one of the ten link descriptors to each link. TABLE 4-66 FORM 43 - Tl LINK ASSIGNMENT CDE TERMII\!AL DISPLAY 11 : 01FM15-JAN-88alarmstatus=NO ALARM TRUUK TYPEBAYSLOTLINK DESC Nlhl COMMENTS l-2-3-4-5- 6-QUIT7-8-9-0-EMERATTENDANT CONSOLE DISPLAY TRUUK TYPEBAY SLOTLINK DESC NWl COMMENTS [BLANK] I>2>3>4>6xlJlT7>8>9>FGNTER4.184 Field Description TRUNK TYPE: This field cannot be edited. BAY, SLOT: This field lists the Bay and...
Page 497
Customer Data Entry (CDE)base.O-ENTER: This softkey appears after the programmer has entered a Link Descriptor Number for a Tl trunk card.Page 175
Page 498
SECTION MITL9109-094-210-NAForm 44 - Tl Network Sync 4.186 This form determines the order in which the links will be used as the network synchronization clock source. When the error threshold of the first clock source is crossed, the second clock is used as the sync source, etc. TABLE 4-67 FORM 44 - Tl NETWORK SYNC CDE TERMINAL DISPLAY II:01 PM 15-JAN-88alarm status = NO ALARM DESCR I PTORBAY SLOTCOMMENTSFirst clock source Second clock source Third clock source Fourth clock source Fifth clock source...
Page 499
Customer Data Entry (CDE) 8-CONFIRM: This softkey appears when an option value has been changed. Press the CONFIRM softkey to enter the change in the data- base.O-ENTER: This softkey appears after the programmer has entered a Tltrunk card Bay/Slot location as a clock source. Page 177