SECTION MITLSI 09-094-320-NARestarting the System 2.11The system may be restarted from the maintenance terminal or console by entering the RE-START command (this will cause a system reset). CHART 2-9 SYSTEM LEVEL: RE-START COMMAND StepActionVerify 1Access MAINTENANCESystem responds by displaying Maintenance menu. application 2Press 1 (SYSTEM softkey).Softkey prompts change. System level is accessed. 3Press 8 (RE-START softkey). Command line responds with RESTART and softkey prompts change to:...
Page 542
System Test Procedures SHOW Command2.12The SHOW command, accessed from the System Level, can be used to display current parameters, namely system date, sys- tem time, Maintenance Port and Printer Port parameters, system iden- tity (including the current software load identification) and reset time. Chart 2-10 shows the steps for testing the SHOW command. CHART 2-10 SYSTEM LEVEL: SHOW COMMAND StepActionVerify 1Access MAINTENANCESystem responds by displaying Maintenance menu. application. 2Press 1 (SYSTEM...
Page 543
SECTION MITL9109-094-320-NADatabase Copying 2.13Customer Data may be copied from one floppy diskette to another for use as a backup source. When database copying takes place, only Customer Data is copied, not the system software. Thr! diskette to which the data is being copied must already contain the system software. Chart 2-l 1 shows the steps for testing copying of the Customer Database. CHART 2-11 SYSTEM LEVEL: DATABASE COPYING StepActionVerify 1Access MAINTENANCESystem responds by displaying...
Page 544
System Test Procedures CHART 2-11 (CONT’D) SYSTEM LEVEL: DATABASE COPYINGStepActionVerify 8Insert a disk containing system software but no Customer Data, then go to Step 9. ORGo to Step 9. 9Press 0 (CONTINUECommand line displays message: softkey). Please wait . . .then Writing database, please wait . . . System copies Customer Data to disk. When copy is complete, command line responds with: Copy successful. If upgrading then RESET - else press CANCEL to continue. 10Press 5 (CANCEL softkey).Softkey...
Page 545
SECTION MITLSI 09-094-320-NAMONITOR Command 2.14 The MONITOR command (accessed from the System Level functions of the Maintenance Terminal) allows the user to mon- itor the progress of system diagnostics as they are run, of main- tenance logs as they occur, of SMDR and DATA SMDR reports as they occur. For further information regarding these, refer to Section MITL9109-094-351-NA, RS-232 Maintenance Terminal. Chart 2-12 shows the steps for testing the MONITOR command. CHART 2-12 SYSTEM LEVEL: MONITOR...
Page 546
System Test Procedures STOP Command2.15The STOP command (accessed from the System Level) allows the user to stop the system monitoring of logs. For information regarding monitoring of logs, refer to MITL9109-094-351-NA, RS-232 Maintenance Terminal. Chart 2-13 shows the steps for testing the STOP command. CHART 2-13 SYSTEM LEVEL: STOP COMMAND StepActionVerify 1Access MAINTENANCESystem responds by displaying Maintenance menu. application. 2Press 1 (SYSTEM softkey).Softkey prompts change. System Level is...
Page 547
SECTION MITL9109-094-320-NADiagnostics 2.16The Diagnostics Level (accessed from the Maintenance menu) allows the user to enable, schedule, and initiate system di- agnostic testing, take equipment out of service, and return it to ser- vice. For further information regarding these, refer to Section MITL9109-094-351-NA, RS-232 Maintenance Terminal. Charts 2-14 through 2-18 show the steps for testing the Diagnostics Level com- mands. CHART 2-14 DIAGNOSTICS LEVEL: TEST COMMAND StepActionVerify 1Access...
Page 548
System Test Procedures CHART 2-14 (CONT’D) DIAGNOSTICS LEVEL: TEST COMMANDStepActionVerify 9Press 0 (ENTER softkey).Command line clears, and the test command is displayed in the display area. If no cards are present in the Bay tested, no other action is seen, and softkey prompts return to the diagnostics level format. If an analog Bay is tested, the message: This function is not available for this device. appears and CANCEL softkey prompt is displayed. If a Bay/Slot/Circuit location is tested, a...
Page 549
SECTION MITL9109-094-320-NACHART 2-14 (CONT’D) DIAGNOSTICS LEVEL: TEST COMMAND StepActionVerify 13Repeat Steps 10 through 12 for remaining device types. 14Press 1 (TEST softkey).Command line responds with: TESTand softkey prompts change. 15Press 3 (EXT-NUM softkey). Command line responds with: TEST EXT-NUM enter Ext. Number then press RETURN: and no softkey prompts are displayed. 16Enter an extension number, Command line clears, and a test message appears in the press RETURN (if extension display area...
Page 550
System Test Procedures Accessing Enabling and Disabling of Diagnostic Functions2.17The MORE-KEYS command is used in the Diagnostics Level to access the enabling and disabling of diagnostics functions (either Power-up or Background diagnostics), removing equipment from service, or returning equipment to service. When the Diagnostics Level softkeys are displayed, press 0 (MORE-KEYS) to access these functions. Chart 2-15 shows the steps for testing enabling and dis- abling of diagnostic functions. Chart...