Page 541

SECTION MITLSI 09-094-320-NARestarting the System
2.11The system may be restarted from the maintenance terminal or
console by entering the RE-START command (this will cause a
system reset).
CHART 2-9
SYSTEM LEVEL: RE-START COMMAND
StepActionVerify
1Access MAINTENANCESystem responds by displaying Maintenance menu.
application
2Press 1 (SYSTEM softkey).Softkey prompts change. System level is accessed.
3Press 8 (RE-START softkey). Command line responds with
RESTART
and 
softkey prompts change to:...

Page 542

System Test Procedures
SHOW Command2.12The SHOW command, accessed from the System Level, can be
used to display current parameters, namely system date, sys-
tem time, Maintenance Port and Printer Port parameters, system iden-
tity (including the current software load identification) and reset time.
Chart 2-10 shows the steps for testing the SHOW command.
CHART 2-10
SYSTEM LEVEL: SHOW COMMAND
StepActionVerify
1Access MAINTENANCESystem responds by displaying Maintenance menu.
application.
2Press 1 (SYSTEM...

Page 543

SECTION MITL9109-094-320-NADatabase Copying
2.13Customer Data may be copied from one floppy diskette to
another for use as a backup source. When database copying
takes place, only Customer Data is copied, not the system software.
Thr! diskette to which the data is being copied must already contain
the system software. Chart 2-l 1 shows the steps for testing copying
of the Customer Database.
CHART 2-11
SYSTEM LEVEL: DATABASE COPYING
StepActionVerify
1Access MAINTENANCESystem responds by displaying...

Page 544

System Test Procedures
CHART 2-11 (CONT’D)
SYSTEM LEVEL: DATABASE COPYINGStepActionVerify
8Insert a disk containing
system software but no
Customer Data, then go to
Step 9.
ORGo to Step 9.
9Press 0 (CONTINUECommand line displays message:
softkey).
Please wait . . .then
Writing database, please wait . . .
System copies Customer Data to disk. When copy is
complete, command line responds with:
Copy successful. If upgrading then RESET 
- else press
CANCEL to continue.
10Press 5 (CANCEL softkey).Softkey...

Page 545

SECTION MITLSI 09-094-320-NAMONITOR Command
2.14 The MONITOR command (accessed from the System Level
functions of the Maintenance Terminal) allows the user to mon-
itor the progress of system diagnostics as they are run, of main-
tenance logs as they occur, of SMDR and DATA SMDR reports as they
occur. For further information regarding these, refer to Section
MITL9109-094-351-NA, RS-232 Maintenance Terminal. Chart 2-12
shows the steps for testing the MONITOR command.
CHART 2-12
SYSTEM LEVEL: MONITOR...

Page 546

System Test Procedures
STOP Command2.15The STOP command (accessed from the System Level) allows
the user to stop the system monitoring of logs. For information
regarding monitoring of logs, refer to 
MITL9109-094-351-NA, RS-232
Maintenance Terminal. Chart 2-13 shows the steps for testing the
STOP command.
CHART 2-13
SYSTEM LEVEL: STOP COMMAND
StepActionVerify
1Access MAINTENANCESystem responds by displaying Maintenance menu.
application.
2Press 1 (SYSTEM softkey).Softkey prompts change. System Level is...

Page 547

SECTION MITL9109-094-320-NADiagnostics
2.16The Diagnostics Level (accessed from the Maintenance menu)
allows the user to enable, schedule, and initiate system di-
agnostic testing, take equipment out of service, and return it to ser-
vice. For further information regarding these, refer to Section
MITL9109-094-351-NA, RS-232 Maintenance Terminal. Charts 2-14
through 2-18 show the steps for testing the Diagnostics Level com-
mands.
CHART 2-14
DIAGNOSTICS LEVEL: TEST COMMAND
StepActionVerify
1Access...

Page 548

System Test Procedures
CHART 2-14 (CONT’D)
DIAGNOSTICS LEVEL: TEST COMMANDStepActionVerify
9Press 0 (ENTER softkey).Command line clears, and the test command is displayed
in the display area. If no cards are present in the Bay
tested, no other action is seen, and 
softkey prompts
return to the diagnostics level format. If an analog Bay is
tested, the message:
This function is not available for this device.
appears and CANCEL 
softkey prompt is displayed. If a
Bay/Slot/Circuit location is tested, a...

Page 549

SECTION MITL9109-094-320-NACHART 2-14 (CONT’D)
DIAGNOSTICS LEVEL: TEST COMMAND
StepActionVerify
13Repeat Steps 10 through
12 for remaining device
types.
14Press 1 (TEST softkey).Command line responds with:
TESTand 
softkey prompts change.
15Press 3 (EXT-NUM softkey). Command line responds with:
TEST EXT-NUM enter Ext. Number then press RETURN:
and no 
softkey prompts are displayed.
16Enter an extension number, Command line clears, and a test message appears in the
press RETURN (if extension display area...

Page 550

System Test Procedures
Accessing Enabling and Disabling of Diagnostic Functions2.17The MORE-KEYS command is used in the Diagnostics Level to
access the enabling and disabling of diagnostics functions
(either Power-up or Background diagnostics), removing equipment
from service, or returning equipment to service. When the Diagnostics
Level 
softkeys are displayed, press 0 (MORE-KEYS) to access these
functions. Chart 2-15 shows the steps for testing enabling and dis-
abling of diagnostic functions. Chart...