System Test Procedures CONTENTS 1. INTRODUCTIONGeneral.............................................1Reason for Issue...................................... 1 SUPERSET 31M and SUPERSET 4@ Telephones.................1 SUPERSET 3TMDN and SUPERSET 4TMDN Telephones............1Section Overview...................................... 1Test Equipment....................................... 2Associated Sections.................................... 2Initial System State.................................... 22....
Page 522
SECTION MITL9109-094-320-NACONTENTS (CONT’D) PAGE6. CUSTOMER FEATURE TESTS Class-of-Service Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 Class-of-Restriction Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 TABLETITLEPAGE 2-l System Access...............................3LIST OF CHARTS CHARTTITLE PAGE 2-l 2-2 2-3 2-4 2-5 2-6 2-7 2-8 2-9 2-10 2-112-12 2-13 2-14 2-15 2-16 2-17 2-18 2-19 2-20 3-l 3-2 3-3 4-l 4-2 4-3 4-4 4-5 4-6 4-7 4-8 4-9Logging In and Out...
Page 523
System Test Procedures CHARTTITLEPAGE 4-10 4-11 4-12 4-13 4-14 4-15 4-16 4-17 4-18 4-19 4-20 5-l 5-2 5-3 5-4 5-5 5-6 5-7 5-8 5-9 5-105-115-12 5-13 5-14 5-15 5-16 5-17 5-18 5-19 5-20 5-21Dial Call Pickup.............................. 61 Directed Call Pickup..........................61 Do Not Disturb..............................62 Extension Reset (Clear All Features)............... 63 Flash for Attendant........................... 64 Hunt Groups (Circular)......................... 65 Hunt Groups...
Page 525
System Test Procedures 1. INTRODUCTIONGeneral 1.01This Section details the system tests to be performed after the system installation (refer to Section MITL9109-094-200-NA, In- stallation) and programming (refer to Section MITLS 109-034-2 IO-NA, Customer Data Entry) have been completed. Upon completion of the tests detailed in this Section, all programming system options and features will have been verified. Reason for Issue 1.02This Section has been issued to provide procedures for sys- tematically...
Page 526
SECTION MITL9109-094-320-NA 0Attendant Console Features 0Customer Feature Tests.Test Equipment 1.06System terts are designed to be carried out without specialized test equipment.Associated Sections 1.07The following Sections are also associated with system tests: 0MITL9109-094-200-NA, Shipping, Receiving, and Installation 0MITL9109-094-206-NA, Installation Forms 0MITLS 109-094-315-NA, Attendant Console Description 0MITLSI 09-094-350-NA, Troubleshooting 0MITL9109-094-351-NA, RS-232 Maintenance...
Page 527
System lest Procedures 2. MAINTENANCE TERMINAL COMMAND VERIFICATIONGeneral 2.01Successful completion of the following tests will confirm that the Maintenance Terminal has been correctly installed and can access the SX-:100 DIGITAL PABX to pat-form directed diagnostic and maintenance commands satisfactorily for each of the different levels of entry. Section MITL9109-094-351-NA, RS-232 Maintenance Termi- nal, is required for reference during these tests. Note:In verifying the functions available at the...
Page 528
SECTION MITL9109-094-320-NA dCHART 2-l LOGGING IN AND OUT OF THE SYSTEM StepActionVerify 1Ensure the terminal isScreen displays a flashing cursor. connected and turned on. 2Press RETURN twice.Screen displays: 1- VT-100 2 - TTY TYPE SELECT A TERMINAL TYPE: 3Press 1, and RETURNScreen displays: 1- MAINTENANCE 2 - CDE 6 - QUIT SELECT AN APPLICATION (OR QUIT TO START OVER): 4Press 1, and RETURNSystem responds with: ENTER USERNAME: 5Enter INSTALLER, andSystem responds with: press RETURNPASSWORD: 6Enter...
Page 529
System Test Procedures CHART 2-l (CONT’D) LOGGING IN AND OUT OF THE SYSTEMStepActionVerify 8Press 2, and RETURN.System responds with prompt for username. 9Enter INSTALLER, an-l System respor.ds with prompt for password. press RETURN. 10Enter 1000, and press RETURN.System responds as in Step 6. If Authorization Failure appears, return to Step 1. Repeat Steps 1 to 3, then Steps 8 and 9. System clears screen, then draws the Customer Data Entry menu (FORMS). 11Press 6System responds with prompts to choose...
Page 530
SECTION MITL9109-094-320-NAStepSetting System Date 2.04System date may be set from the Maintenance Terminal. The new date will be reflected on the Maintenance Terminal display, the Attendant Console LCD display, and SUPERSEJ 4 telephone LCD displays. Chart 2-2 shows the steps for testing setting of the system date.CHART 2-2 SETTING SYSTEM DATE Action Access MAINTENANCE application. Press 1(SYSTEM softkey). Press 1 (SET softkey). Press 1 (DATE softkey). Enter date according to displayed numeric format...