Page 561
24. Testing and Troubleshooting the System Implementation and Service Manual System Troubleshooting Table24-33 System Setup parameters: · Verify that an Intercom Paging Code is specified on the Intercom Paging tab in System Setup. · Verify that the Release Code for Intercom Paging is specified on the Intercom Paging tab. Class of Service dialog box: · Verify that the Intercom Paging checkbox is enabled. Subscriber Settings dialog box: · If intercom paging was activated by the subscriber over the...
Page 562
24. Testing and Troubleshooting the System Implementation and Service Manual System Troubleshooting Table24-34 Cannot access mailbox featuresResolution Possibilities: · Verify that the feature in question is enabled on the Class of Service dialog box. · Verify that the sentinel permits the feature. For information on verifying the features enabled on a sentinel, see the topic, Displaying Features Enabled on the Sentinel, later in this section. · Verify that the feature in question is permitted in the...
Page 563
24. Testing and Troubleshooting the System Implementation and Service Manual System Troubleshooting Table24-35 Mailbox is fullResolution Possibilities: · The value specified in the Max Messages field in the class of service assigned to the mailbox has been reached. Delete messages to allow for more recording time in the mailbox or increase the limits. · Assign a new class of service to the mailbox. · Run Quick Assist using the Update Partial option. For information on running the Quick Assist...
Page 564
24. Testing and Troubleshooting the System Implementation and Service Manual System Troubleshooting Table24-36 Messages vanishing from mailboxesResolution Possibilities: · Verify that the correct date and time are set on the PC clock. Mailbox Entry dialog box: · Deactivate the Auto Forwarding feature if is active. · Note that the number of days to save messages can be set to 99, allowing saved messages to remain on the messaging system indefinitely. Class of Service dialog box: · Note that a message...
Page 565
24. Testing and Troubleshooting the System Implementation and Service Manual System Troubleshooting Table24-37 System Setup parameters: · Verify that the Port Parameters tab has at least one port enabled for outbound and that the same port is also enabled for Message Indicators. · Verify that the Permit Message Indicators parameter on the MI tab is enabled. · Verify that the MI prefix and suffix on and off codes are entered in the fields on the MI tab. If using the Dialogic SX or SL integration, see...
Page 566
24. Testing and Troubleshooting the System Implementation and Service Manual System Troubleshooting Table24-38 System Setup parameters: · Verify that the message indicator prefix is entered correctly on the MI tab. · Verify that the Permit Message Indicators parameter on the MI tab is enabled. · Verify that COMMMW L is enabled on the Simplified Message Desk Interface tab. · Verify that the Port Parameters tab has at least one port enabled for outbound and that the same port is also enabled for...
Page 567
24. Testing and Troubleshooting the System Implementation and Service Manual System Troubleshooting Table24-39 DTONWAIT, unless DTONDET is set to 0. · The value for DTONDET may be set too low. If it is, the messaging system may hang up prematurely. Adjust this parameter only if instructed to by a technical support representative. · The value for SCHDW AIT on the Outbound Calls tab may be set too low. If it is, the messaging system may not detect a dial tone on an outbound line and must reschedule the...
Page 568
24. Testing and Troubleshooting the System Implementation and Service Manual System Troubleshooting Table24-40 System Setup Parameters: · Verify that at least one port is enabled for Outbound and Message Notification in the Port Parameters tab. · Verify that the values entered for DTONWAIT on the Message Delivery tab and DTONDET on the Hangup tab are set at least 400 units apart, unless DTONDET is 0. · Verify that the value for DTONDET is greater than the value for DTONWAIT, unless DTONDET is 0. ·...
Page 569
24. Testing and Troubleshooting the System Implementation and Service Manual System Troubleshooting Table24-41 OctelNet/AMIS messages are returned to mailboxes Resolution Possibilities: · Verify that OctelNet is enabled on the sentinel. For information on verifying the features enabled on a sentinel, see the topic, Displaying Features Enabled on the Sentinel, later in this chapter. · Verify that the access number on the Network Maintenance dialog box is correct. · If using Dial Plan, verify that the...
Page 570
24. Testing and Troubleshooting the System Implementation and Service Manual System Troubleshooting Table24-42 System Setup parameters: · Verify that the Minimum Message Length parameter on the Message Timing tab is set to the recommended setting, 2 seconds. Note that any message shorter in length than two seconds is automatically deleted. · If setting the Minimum Message Length parameter on the Message Timing tab to 2 seconds does not correct the problem, set the parameter to 4 seconds and set the...