GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Translations and Testing 
171 Switch-to-INTUITY Translations 
Processor Channels
Use the change communication-interface processor-channels command to 
administer the processor channels.
nProc Chan — Use channel 59. It is recommended that this should match 
the Session Local field used for this link.
nEnable — Enter y.
nAppl — Enter audix.
nGtwy To — Not used for GuestWorks.
nMode — Not used for GuestWorks.
nInterface Link — Enter the...

Page 182

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Translations and Testing 
172 Switch-to-INTUITY Translations 
X.25 Link (INTUITY)
Checking the Switch Link
Use the Customer/Services Administration, Diagnostics, Switch Interface 
Diagnostics command to determine if the link is active. During initial installation, 
this screen should show that the link is busied out.
After pressing   to change the function key labels, the following function keys 
control the status of the link:
n...

Page 183

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Translations and Testing 
173 Switch-to-INTUITY Translations 
Administer the Switch Interface (R4.4)
Use the Switch Interface Administration, DCIU Interface Administration com-
mand on the INTUITY to administer the link to the switch.
nExtension Length — Enter the extension length from the switch dial 
plan.
nHost Switch Number — Enter 1.
nAUDIX Number — Enter 1. This must match the Machine ID field on 
the switch Processor Channel...

Page 184

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Translations and Testing 
174 Switch-to-INTUITY Translations 
Administer the Switch Interface (R5)
Use the Switch Interface Administration command on the INTUITY to adminis-
ter the link to the switch.
nExtension Length — Enter the extension length from the switch dial 
plan.
nHost Switch Number — Enter 1.
nAUDIX Number — Enter 1. This must match the Machine ID field on 
the switch Processor Channel screen.
nLogical Channel— Enter...

Page 185

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Translations and Testing 
175 Switch-to-INTUITY Translations 
nstatus link X, where X is the X.25 link number.
The following tests can be run from the INTUITY to test the link to the switch:
nUse the command Lodging Administration, press  to bring up the com-
mand menu, and select LDG/PMS Link Restart to restart the switch-to-
INTUITY link.
nCustomer/Services Administration, Diagnostics, Switch Link Diag-
nostics, Link Diagnostics...

Page 186

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Translations and Testing 
176 Switch-to-INTUITY Translations 
Mode Code Signaling
The Mode Code Integration link requires administration on both the switch and the 
INTUITY. Any switch types can use Mode Code Integration, but TCP/IP or X.25 
are the recommended methods for messaging links.
Mode Code Integration Link (Switch)
Translating the Mode Code Integration link involves the following:
nEnabling the Mode Code feature under the...

Page 187

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Translations and Testing 
177 Switch-to-INTUITY Translations 
Use the change system-parameters mode-code command to verify that the 
default mode code parameters are correct for this installation.
Mode Code Integration (INTUITY)
Mode Code Integration on the INTUITY is described in the following documents:
nINTUITY Messaging Solutions Release 4 MAP/5P System Installation
nINTUITY Messaging Solutions Integration with System 75,...

Page 188

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Translations and Testing 
178 Switch-to-INTUITY Translations 
INTUITY AUDIX Voice Ports (Switch)
Use the add station command to administer the voice ports that are linked to the 
INTUITY system. On Page 1, assign the following fields as shown:
nExtension — The extension must be in the dial plan but not assigned for 
any other purpose.
nType — Enter 2500 for the station type when using the TCP/IP or X.25 link. 
Enter VMI for the...

Page 189

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Translations and Testing 
179 Switch-to-INTUITY Translations 
The following is an example of Page 1 when Mode Code Integration is installed.
On Page 2:
nLWC Reception — Enter audix when using TCP/IP or X.25 signaling. 
Enter none when using Mode Code signaling.
nLWC Activation — Enter n when using TCP/IP or X.25 signaling. Enter 
y when using Mode Code signaling.
nSwitchhook Flash — Enter y.
nDistinctive Audible Alerting — Enter n...

Page 190

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Translations and Testing 
180 Switch-to-INTUITY Translations 
On Page 3, set the Line Appearance field to call-appr.
After you assign the first port, use the duplicate station command to assign the 
rest of the ports.
add station 720Page 3 of 3
                                     STATION
 SITE DATA
       Room:  Headset? n
       Jack:                                            Speaker? n
      Cable:...