GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Translations and Testing 161 Switch-to-INTUITY Translations Administer the TCP/IP Networking (R5) Use the TCP/IP Administration, Network Addressing command to access the TCP/IP administration. NOTE: If this administration is already complete, verify that the settings are accu- rate for your installation. nTCP/IP Interface — Use the default eeE_0. nHost Name — Enter the UNIX name for the INTUITY system. This name is...
Page 172
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Translations and Testing 162 Switch-to-INTUITY Translations Select a Switch Type (R4.4 only) Use the Switch Interface Administration, Switch Selection command to access the switch selection administration. nCountry — Enter the country where this system is installed. nSwitch — Enter DEFINITY OVERLAN. Administer the Switch Interface (R4.4 and R5) Use the Switch Interface Administration, Call Data Interface Administration, Switch...
Page 173
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Translations and Testing 163 Switch-to-INTUITY Translations nTCP Port — Enter the TCP port number (5002 or 6001-6999). This must match the Interface Channel field of the switch Processor Channel screen. The default for an INTUITY system is 5002. Reboot the INTUITY System (R4.4 Only) You must now reboot the INTUITY system. This is not required on an R5 system. 1. Use the Customer/Services Administration, System Management, System...
Page 174
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Translations and Testing 164 Switch-to-INTUITY Translations Testing the TCP/IP Link The following tests can be run from the switch to test the link to the INTUITY: nping node-name name board CCs [packet-length YYYY repeat ZZZ], where name is the INTUITY node name, CCs is the equipment location of the C-LAN circuit pack, YYYY is the size of the test packet, and ZZZ is the number of times the test will be repeated. The packet...
Page 175
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Translations and Testing 165 Switch-to-INTUITY Translations nstatus link X, where X is the TCP/IP link number. In this example of Page 1, the system shows that the link is connected and that the link is in service. nAlso check Page 3, because that is where the system shows whether the link is up or down. If the link is not up, there is a problem somewhere in translations or connectivity. nstatus data-module XXXX, where XXXX is...
Page 176
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Translations and Testing 166 Switch-to-INTUITY Translations ntrace-route ip-address address board CCs, where address is the INTU- ITY IP address, and CCs is the equipment location of the C-LAN circuit pack. The command displays the hops traversed from source to destina- tion, along with the IP addresses of the hop points and final destination, and the observed round-trip delay from the source to each hop point. If no reply is...
Page 177
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Translations and Testing 167 Switch-to-INTUITY Translations The following tests can be run from the INTUITY system to test the link to the switch: nCustomer/Services Administration, Diagnostics, Switch Link Diag- nostics, Link Diagnostics This screen is an example of a TCP/IP link. It shows the link being in ser- vice. If the link status and session status show DOWN, use the following function keys to test the link: — tests to...
Page 178
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Translations and Testing 168 Switch-to-INTUITY Translations nCustomer/Services Administration, Diagnostics, TCP/IP Diagnostics, Send & Receive Test Packets After entering the switch IP address, press to start the test. This sends test packets between the INTUITY and the switch. The system tests to see whether all the packets are transmitted and whether they are transmitted in the correct sequence. If there is high (greater...
Page 179
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Translations and Testing 169 Switch-to-INTUITY Translations X.25 Signaling The X.25 PI link requires administration on both the switch and the INTUITY. Only the si and r systems can use an X.25 link. A csi system must use TCP/IP or Mode Code Integration. This section includes procedures for testing the link. X.25 Link (Switch) Use the following procedures to administer the link between the switch and the INTUITY for...
Page 180
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Translations and Testing 170 Switch-to-INTUITY Translations The following table is an example of how you can administer the processor interface channels (your extensions will differ). Only channel 01 will be enabled later to handle the messaging traffic. The other channels are used for maintenance and testing. Data Module on an r System Use the add data-module command on an r system to administer the data mod- ule parameters for...