GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Translations and Testing 
161 Switch-to-INTUITY Translations 
Administer the TCP/IP Networking (R5)
Use the TCP/IP Administration, Network Addressing command to access the 
TCP/IP administration.
NOTE:
If this administration is already complete, verify that the settings are accu-
rate for your installation.
nTCP/IP Interface — Use the default eeE_0.
nHost Name — Enter the UNIX name for the INTUITY system. This name is...

Page 172

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Translations and Testing 
162 Switch-to-INTUITY Translations 
Select a Switch Type (R4.4 only)
Use the Switch Interface Administration, Switch Selection command to 
access the switch selection administration.
nCountry — Enter the country where this system is installed.
nSwitch — Enter DEFINITY OVERLAN.
Administer the Switch Interface (R4.4 and R5)
Use the Switch Interface Administration, Call Data Interface Administration, 
Switch...

Page 173

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Translations and Testing 
163 Switch-to-INTUITY Translations 
nTCP Port — Enter the TCP port number (5002 or 6001-6999). This must 
match the Interface Channel field of the switch Processor Channel 
screen. The default for an INTUITY system is 5002.
Reboot the INTUITY System (R4.4 Only)
You must now reboot the INTUITY system. This is not required on an R5 system.
1. Use the Customer/Services Administration, System Management, 
System...

Page 174

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Translations and Testing 
164 Switch-to-INTUITY Translations 
Testing the TCP/IP Link
The following tests can be run from the switch to test the link to the INTUITY:
nping node-name name board CCs [packet-length YYYY repeat ZZZ], 
where 
name is the INTUITY node name, CCs is the equipment location of 
the C-LAN circuit pack, 
YYYY is the size of the test packet, and ZZZ is the 
number of times the test will be repeated. The packet...

Page 175

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Translations and Testing 
165 Switch-to-INTUITY Translations 
nstatus link X, where X is the TCP/IP link number. In this example of 
Page 1, the system shows that the link is connected and that the link is in 
service.
nAlso check Page 3, because that is where the system shows whether the 
link is up or down. If the link is not up, there is a problem somewhere in 
translations or connectivity.
nstatus data-module XXXX, where XXXX is...

Page 176

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Translations and Testing 
166 Switch-to-INTUITY Translations 
ntrace-route ip-address address board CCs, where address is the INTU-
ITY IP address, and 
CCs is the equipment location of the C-LAN circuit 
pack. The command displays the hops traversed from source to destina-
tion, along with the IP addresses of the hop points and final destination, 
and the observed round-trip delay from the source to each hop point. If no 
reply is...

Page 177

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Translations and Testing 
167 Switch-to-INTUITY Translations 
The following tests can be run from the INTUITY system to test the link to the 
switch:
nCustomer/Services Administration, Diagnostics, Switch Link Diag-
nostics, Link Diagnostics
This screen is an example of a TCP/IP link. It shows the link being in ser-
vice.
If the link status and session status show DOWN, use the following function 
keys to test the link:
—  tests to...

Page 178

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Translations and Testing 
168 Switch-to-INTUITY Translations 
nCustomer/Services Administration, Diagnostics, TCP/IP Diagnostics, 
Send & Receive Test Packets
After entering the switch IP address, press   to start the test. This sends 
test packets between the INTUITY and the switch. The system tests to see 
whether all the packets are transmitted and whether they are transmitted in 
the correct sequence. If there is high (greater...

Page 179

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Translations and Testing 
169 Switch-to-INTUITY Translations 
X.25 Signaling
The X.25 PI link requires administration on both the switch and the INTUITY. Only 
the 
si and r systems can use an X.25 link. A csi system must use TCP/IP or Mode 
Code Integration. This section includes procedures for testing the link.
X.25 Link (Switch)
Use the following procedures to administer the link between the switch and the 
INTUITY for...

Page 180

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Translations and Testing 
170 Switch-to-INTUITY Translations 
The following table is an example of how you can administer the processor 
interface channels (your extensions will differ). Only channel 01 will be enabled 
later to handle the messaging traffic. The other channels are used for 
maintenance and testing.
Data Module on an r System
Use the add data-module command on an r system to administer the data mod-
ule parameters for...