Page 211
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Translations and Testing 201 Switch-to-Call Accounting Translations nCDR Account Code Length — When setting up billing for forwarding faxes (see “ Billing Considerations When Forwarding Faxes” on Page 104), set this field to the number of digits used for extensions in the dial plan. As shown on Page 141 , enable CDR Reports for each trunk group. Testing the Switch-to-Call Accounting Link To test the CDR link, use the status...
Page 212
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Translations and Testing 202 INTUITY Lodging Call Accounting-to-PMS Translations INTUITY Lodging Call Accounting-to-PMS Translations The data link between the INTUITY Lodging Call Accounting and the PMS must be administered by the Homisco technician when he or she installs the software on the INTUITY platform. If a stand-alone call accounting system (such as Xiox) is used, the vendor must assist in setting up the call...
Page 213
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Translations and Testing 203 Switch-to-PMS Link Translations Switch-to-PMS Link Translations Administration of the switch-to-PMS link includes the following: nNetwork control (netcon) data module for si system (Pa ge 2 03) nData module (Page 204) nHospitality parameters (Page 204) nHousekeeping status feature access codes and definitions (Pag e 20 7) nControlled restrictions (Pag e 20 9). Network Control (Netcon) Data Module Use...
Page 214
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Translations and Testing 204 Switch-to-PMS Link Translations Data Modules Use the add data-module command to administer the data module connected between the switch and the PMS. Hospitality Parameters Use the change system-parameters hospitality command to administer the hospitality parameters for the PMS. These assignments must be coordinated with the PMS vendor and the customer. On Page 1, administer the following: nFor the...
Page 215
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Translations and Testing 205 Switch-to-PMS Link Translations nIf the PMS Protocol Mode is transparent (also known as Names proto- col), set the Seconds before PMS Link Idle Timeout to 20 and the Milliseconds before PMS Link Acknowledgement Timeout to500. If the PMS Protocol Mode is normal, set the Seconds before PMS Link Idle Timeout to 20 and the Milliseconds before PMS Link Acknowledgement Timeout to 300. If the PMS...
Page 216
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Translations and Testing 206 Switch-to-PMS Link Translations On Page 2, administer the following: nThe Number of Digits From PMS field should be left blank, and the Digit to Insert/Delete field may need to be administered. If the room numbers use a combination of 3- and 4-digit or 4- and 5-digit exten- sion numbers, you must enter the leading digit that must be inserted when sent from the PMS to the switch and that must be...
Page 217
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Translations and Testing 207 Switch-to-PMS Link Translations nThe Number of Digits in PMS Coverage Path field indicates whether the coverage paths are 3 or 4 digits long. Housekeeping Status Use the change feature-access-codes command to assign the housekeeping status feature access codes. Administer only the feature access codes that the vendor supports and that match the status definitions. change system-parameters hospitality...
Page 218
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Translations and Testing 208 Switch-to-PMS Link Translations Use the change system-parameters hospitality command to define whether the housekeeping staff will use IDs, and to administer the housekeeping status definitions. On Page 1, the Number of Housekeeper ID Digits field determines the length of the housekeeping staff ID numbers. Valid entries are 0 to 6. If set to 0, housekeeping IDs are not used. On Page 2, enter the...
Page 219
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Translations and Testing 209 Switch-to-PMS Link Translations Controlled Restrictions When Controlled Restrictions are applied to guest rooms, calls made to those rooms or from those rooms are routed to intercept treatment. The recommended intercept treatment is shown in the following example. Use the change system-parameters features command to set the controlled restriction intercept treatment. The PMS automatically applies...
Page 220
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Translations and Testing 210 Switch-to-PMS Link Translations Testing the Switch-to-PMS Link To test the switch-to-PMS link, have the hotel designate a room for testing. Testing the switch-to-PMS link includes the following: nLink testing with the RS232 mini-tester (Page 211) nNetcon and data module testing (Page 213) nPMS testing and status (Pag e 21 4) nDatabase swap testing (Pa ge 2 15) nCheck-in and check-out testing (Page...