Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 131
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-13 Three-Pair and Four-Pair Modularity 5 Tab le 5-4 lists voic e and d ata terminals that c an c onnec t to the system. Table 5-4. Voice and Data Terminals Te r m i n a l Ty p e Multi-b utton Elec tronic Telep hone (MET) sets: 10, 20, 30 ButtonVo i c e Analog : 500, 2500/2554, 2500 DMGC, 2500YMGK, S203A Sp eakerp...
Page 132
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-14 Three-Pair and Four-Pair Modularity 5 Administration Terminals Tab le 5-5 lists the ad ministration terminals that c an c onnec t to the system. * The keyb oard s and terminals are interc hangeable when an ad ap ter c ab le is used . NOTE: The old er version of 715 BCT (the 715 Business Communications System (BCS))...
Page 133
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-15 Adjunct Power Connections 5 Adjunct Power Connections Fi g u re 5 - 8 shows typ ic al c onnec tion loc ations for ad junc t p ower. Figure 5-8. Example Adjunct Power Connections For this fig ure, the following examp le is used : a. If 25 telep hones are c onnec ted to the system and all 25 telep hones need ad...
Page 134
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-16 Adjunct Power Connections 5 Local and Phantom Power A c onsole’s maximum distanc e from the system is limited . The maximum d istanc e for a 302C1 c onsole is as shown in Tab le 5-6 . Auxiliary Power The nonessential func tions of an attend ant c onsole and its op tional 26A1 or 24A1 selec tor c onsole d erive...
Page 135
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-17 Attendant Console 5 Attendant Console Figure 5-9. 302C1 Console 1. Install the Attend ant Console and c onnec t the mod ular c ord to the information outlet. 2. Install lab els per the Attend ant Console form and the Disp lay Mod ule form assig nments. 3. Install a Digital Line c irc uit p ac k in the assig ned...
Page 136
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-18 Install 26B1 Selector Console 5 Dual Wiring of Two-Wire and Four-Wire Endpoints Do not simultaneously wire a two-wire and four-wire endp oint to the same eq uip ment loc ation in an MDF. The DEFINITY System uses sep arate c irc uit p ac ks to interfac e two- and four-wire end p oints. Install 26B1 Selector...
Page 137
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-19 Install Remote Network Interface 5 Alarm Output The system provides a relay contac t that can operate a customer-provided alarm, suc h as a lig ht or b ell. The c irc uitry and p ower sourc e are c ustomer- provided. The alarm device must not exc eed a rating of more than 30 VAC RMS or 60 VDC at 0.75 A. 1....
Page 138
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-20 Install Remote Network Interface 5 Remote Network Interface Installation 1. Determine the network interfac e trunk ap pearanc e at the g reen trunk/auxiliary field . 2. Lab el the terminals for the trunk app earanc e. 3. Install jump ers b etween the trunk app earanc e and Remote Network Interfac e terminals....
Page 139
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-21 Install Off-Premises Station Wiring 5 5. Enter first-only in the Alarm Orig ination to OSS Numb ers field and p ress En t e r to enab le Alarm Orig ination (to the first OSS). Also enab le Cleared Alarm Notific ation and Restart Notific ation, if need ed. NOTE: Release 8 sup ports up to two OSS telep hone...
Page 140
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-22 Install Off-Premises or Out-of-Building Stations 5 Install Off-Premises or Out-of-Building Stations Out-of-b uild ing c amp us stations are those telep hones/voic e terminals not p hysic ally loc ated in the same b uild ing as the eq uip ment room b ut are loc ated on the same p rop erty. Analog Off-Premises...