Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual

Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual

Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 131

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Install and Wire Telephones and Other Equipment 
5-13 Three-Pair and Four-Pair Modularity 
5
Tab le 5-4 lists voic e and  d ata terminals that c an c onnec t to the system.
Table 5-4. Voice and Data Terminals 
Te r m i n a l Ty p e
Multi-b utton Elec tronic  Telep hone (MET) sets: 
10, 20, 30 ButtonVo i c e
Analog :
500, 2500/2554, 2500 DMGC, 2500YMGK, S203A Sp eakerp...

Page 132

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Install and Wire Telephones and Other Equipment 
5-14 Three-Pair and Four-Pair Modularity 
5
Administration Terminals
Tab le 5-5 lists the ad ministration terminals that c an c onnec t to the system.
*
The keyb oard s and  terminals are interc hangeable when an ad ap ter c ab le is used .
NOTE:
The old er version of 715 BCT (the 715 Business Communications System (BCS))...

Page 133

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Install and Wire Telephones and Other Equipment 
5-15 Adjunct Power Connections 
5
Adjunct Power Connections
Fi g u re  5 - 8 shows typ ic al c onnec tion loc ations for ad junc t p ower.
Figure 5-8. Example Adjunct Power Connections
For this fig ure, the following  examp le is used :
a. If 25 telep hones are c onnec ted to the system and  all 25 telep hones need  
ad...

Page 134

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Install and Wire Telephones and Other Equipment 
5-16 Adjunct Power Connections 
5
Local and Phantom Power
A c onsole’s maximum distanc e from the system is limited . The maximum 
d istanc e for a 302C1 c onsole is as shown in Tab le 5-6
. 
Auxiliary Power
The nonessential func tions of an attend ant c onsole and  its op tional 26A1 or 24A1 
selec tor c onsole d erive...

Page 135

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Install and Wire Telephones and Other Equipment 
5-17 Attendant Console 
5
Attendant Console
Figure 5-9. 302C1 Console
1. Install the Attend ant Console and  c onnec t the mod ular c ord to the 
information outlet.
2. Install lab els per the Attend ant Console form and  the Disp lay Mod ule form 
assig nments.
3. Install a Digital Line c irc uit p ac k in the assig ned...

Page 136

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Install and Wire Telephones and Other Equipment 
5-18 Install 26B1 Selector Console 
5
Dual Wiring of Two-Wire and Four-Wire 
Endpoints
Do not simultaneously wire a two-wire and  four-wire endp oint to the same 
eq uip ment loc ation in an MDF. The DEFINITY System uses sep arate c irc uit 
p ac ks to interfac e two- and  four-wire end p oints.
Install 26B1 Selector...

Page 137

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Install and Wire Telephones and Other Equipment 
5-19 Install Remote Network Interface 
5
Alarm Output
The system provides a relay contac t that can operate a customer-provided 
alarm, suc h as a lig ht or b ell. The c irc uitry and  p ower sourc e are c ustomer- 
provided. The alarm device must not exc eed a rating of more than 30 VAC RMS 
or 60 VDC at 0.75 A. 
1....

Page 138

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Install and Wire Telephones and Other Equipment 
5-20 Install Remote Network Interface 
5
Remote Network Interface Installation
1. Determine the network interfac e trunk ap pearanc e at the g reen 
trunk/auxiliary field .
2. Lab el the terminals for the trunk app earanc e.
3. Install jump ers b etween the trunk app earanc e and  Remote Network 
Interfac e terminals....

Page 139

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Install and Wire Telephones and Other Equipment 
5-21 Install Off-Premises Station Wiring 
5
5. Enter first-only
 in the Alarm Orig ination to OSS Numb ers field  and  p ress 
En t e r to enab le Alarm Orig ination (to the first OSS).
Also enab le 
Cleared  Alarm Notific ation and  Restart Notific ation, if need ed. 
NOTE:
Release 8 sup ports up  to two OSS telep hone...

Page 140

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Install and Wire Telephones and Other Equipment 
5-22 Install Off-Premises or Out-of-Building Stations 
5
Install Off-Premises or 
Out-of-Building Stations
Out-of-b uild ing  c amp us stations are those telep hones/voic e terminals not 
p hysic ally loc ated  in the same b uild ing  as the eq uip ment room b ut are loc ated  
on the same p rop erty.
Analog Off-Premises...
Start reading Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual

Related Manuals for Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual