Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 121
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-3 Telephone Connection Example 5 Connect Adjunct Power The 400B2 ad ap ter is c onvenient for c onnec ting loc al -48 VDC power to a modular plug. See Fi g u re 5 - 2 . Figure 5-2. 400B2 Adapter Connecting to a Modular Plug Ad junc t p ower c an be p rovid ed from the eq uip ment room or eq uip ment c loset with...
Page 122
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-4 Analog Station or 2-Wire Digital Station Example 5 Analog Station or 2-Wire Digital Station Example This examp le is typ ic al of the 2-wire d ig ital stations (603E, 84xx, 94xx, 302C1), 2-wire analog stations (500, 2500, 71xx), analog Central Offic e (CO) trunks, Direc t Inward Dial (DID) trunks, and external...
Page 123
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-5 Analog Tie Trunk Example 5 Analog Tie Trunk Example This examp le shows how to c onnec t analog tie trunk wiring from one DEFINITY System to another DEFINITY System. Figure 5-4. Analog Tie Trunk Wiring 1. Set the option switc hes on the p ort c irc uit p ac k (suc h as TN760) as described in Ap p end ix A, ‘‘Op...
Page 124
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-6 Digital Tie Trunk Example 5 Digital Tie Trunk Example This examp le shows how to c onnec t d ig ital tie trunk wiring from one DEFINITY System to another DEFINITY System. See Fig ure 5-5 . Figure 5-5. Digital Tie Trunk Wiring 1. Install c ross-c onnec t jump ers to c onnec t the p ins from the d ig ital trunk c irc...
Page 125
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-7 DS1 Tie Trunk Example 5 DS1 Tie Trunk Example Dig ital Sig nal Level 1 (DS1) tie trunks p rovid e a 1.544 Mb p s (T1) or 2.048 Mb p s (E1) d ig ital d ata servic e b etween two c olloc ated systems or between the system and a d ata network. The following c ab les c an b e used : nC6C connector cable (comcode...
Page 126
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-8 DS1 Tie Trunk Example 5 DS1 Tie Trunks Using T1 Channel Service Unit The T1 Channel Servic e Unit (CSU) interfac es the DS1 tie trunks with the 1.544 Mbps digital facility. 1. Connec t the DS1 tie trunk to a T1 CSU. See Fi g u re 5 -6 . NOTE: A 3150 CSU is shown, a 120A Integ rated CSU (ICSU) may b e used . 2....
Page 127
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-9 Auxiliary Connector Outputs 5 Auxiliary Connector Outputs The Control Carrier outputs c able pinouts are shown in Ta b l e 5 - 2. The Control Carrier AUX c onnec tor outp uts inc lud e the following : nAlarm monitoring for the auxiliary c ab inet nSeven -48 VDC p ower sourc es for emerg enc y transfer units...
Page 128
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-10 Auxiliary Connector Outputs 5 3 * External alarm with sig nal incoming to system. ** External alarm with sig nal outgoing from system. 1 Color desig nation is the main wire c olor and the c olor of the strip e on the wire. 2 The following wire colors ap p ly to Ta b l e 5 - 2: WWhite BL Blue O Orange GGreen BR...
Page 129
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-11 Three-Pair and Four-Pair Modularity 5 Tab le 5-3 p rovid es p ort c irc uit p ac k and telephone p in d esig nations. Three-Pair and Four-Pair Modularity Fi g u re 5 - 7 shows 3-p air and 4-pair mod ularity from the p ort c irc uit p ac k to the voic e or d ata terminal. Refer to Chapter 2, ‘‘Install Telec...
Page 130
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-12 Three-Pair and Four-Pair Modularity 5 Figure 5-7. 3-Pair and 4-Pair Modularity Figure Notes 1. Port Circ uit Pac k 2. System Cab inet Connec tor Pins (3-Pair Mod ularity) 3. Main Distrib ution Frame (MDF) Pins (3-Pair Mod ularity) 4. Input to Information Outlet (4-Pair Mod ularity)5. Ad junc t Power 6. Output From...