Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual
Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual
Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 101
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-29 Set System Maintenance Parameters 3 Set System Maintenance Parameters 1. Verify the sc reen d isp lays command: 2. Type change system-parameters maintenance and press En te r. Verify that the sc reen d isp layed is similar to Sc reen 3-7 . The sc reen shows d efault values and the c ursor is positioned on Product...
Page 102
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-30 Administer Attendant Console 3 Administer Attendant Console 1. Type craft at the login: prompt. 2. Type display system-parameters country-options and press En te r to verify the system’s c omp and ing mod e for its loc al stations is set to the d esired value (usually, A-Law for Europ e and mu-Law for North Americ a...
Page 103
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-31 Save Translations 3 Screen 3-8. Typical Save Translation Screen 4. Verify a 0 is d isp layed in the Error Cod e c olumn for eac h Switc h Proc essing Element (SPE). A 0 ind ic ates the save translation was suc c essfully c ompleted . If a 0 did not ap p ear, the save translation d id not c omp lete. Rec ord the error...
Page 104
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-32 Installation Completion 3 Installation Completion After the system is ac tivated , it must b e tested for prop er op eration. See Chap ter 4, ‘‘Test the System’’. After c omp letion of the system tests, the telep hones and other eq uip ment must b e installed . See Chap ter 5, ‘‘Install and Wire Telep hones and Other Eq...
Page 105
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-33 DEFINITY AUDIX System Power Procedures 3 DEFINITY AUDIX System Power Procedures Manually Power Down AUDIX System A yellow c aution stic ker on the system’s power unit notifies tec hnic ians to shut d own the DEFINITY AUDIX System p rior to p owering d own the system. 1. Using a p ointed ob jec t, suc h as a pap er c lip or...
Page 106
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-34 DEFINITY AUDIX System Power Procedures 3
Page 107
Test the System 4-1 4 DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 4 Test the System The following tests verify the Time Division Multip lexing (TDM) c ab les, terminators, and the Inter-Cabinet Cab les (ICC). If a FAIL Result c od e is seen or other p rob lems are ind ic ated , c hec k these c ab les. If p rob lems p ersist, refer to DEFINITY Enterp rise Communic ations Server Release 8 Maintenanc e for...
Page 108
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Test the System 4-2 Check System Status for Each Cabinet 4 Check System Status for Each Cabinet The system status may sug g est p rob lem areas. Sp ecific tests later p rovid e more sp ec ific d iag nostic information. 1. Verify the terminal sc reen d isp lays: command: 2. Type status system all-cabinets and press En t e r. 3. Verify the sc reen d isp lays system...
Page 109
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Test the System 4-3 Check System Status for Each Cabinet 4 Screen 4-2. Sample System Status Screen for Cabinet 2 (Page 2 of 3) NOTE: In the first sec tion of the rep ort in Sc reen 4-2, all Tone-Cloc ks should rep ort a SERVICE STATE of in for Cab inet 2. In the sec ond sec tion of the rep ort, all TDM b uses should rep ort a SERVICE STATE of in . In the third...
Page 110
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Test the System 4-4 Check Circuit Pack Configuration 4 Check Circuit Pack Configuration The list configuration report provides a list of circuit packs c onnected to the system and rec ognized b y the software. 1. Verify the sc reen d isp lays command: 2. Type list configuration all and p ress En t e r. 3. Verify the sc reen d isp lays list c onfig uration similar...