Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 171
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-53 CAMA/E911 Installation 5 Screen 5-4. Feature Access Code (FAC) form (page 1) 11. The Feature Ac c ess Cod e (FAC) sc reen (p ag e 1) ap p ears. 12. In the Auto Route Selection (ARS) Access Code 1: field, ad minister the ARS ac c ess c od e (in the examp le above, typ e 9 ) and press En t e r (must matc h d ial p...
Page 172
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-54 CAMA/E911 Installation 5 Screen 5-5. ARS Digit Analysis Table 14. On ARS Dig it Analysis Tab le sc reen app ears. In the Dialed String field , in the first emp ty row, enter 11 . 15. In the Total Mn field , enter 2 . 16. In the Total Mx field , enter 2 . 17. In the Rte Pat field , enter the d esired Route...
Page 173
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-55 CAMA/E911 Installation 5 24. At the p rompt, typ e change route-pattern (the route pattern to b e c hanged ; in the examp le b elow, the route pattern is 11) and p ress En te r. Screen 5-6. Route Pattern form (Page 1) 25. On the Route Pattern sc reen, in Grp. No . field , enter the CAMA trunk g roup number....
Page 174
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-56 CAMA/E911 Installation 5 28. At the p rompt, typ e change route-pattern (the route pattern to b e c hanged ; in the examp le b elow, the route pattern is 12) and p ress En te r. Screen 5-7. Route Pattern form (Page 1) 29. On the Route Pattern sc reen, in Grp. No . field , typ e the CAMA trunk g roup number and...
Page 175
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-57 CAMA/E911 Installation 5 Screen 5-8. CAMA Numbering Format form 33. In the CAMA Numb ering - E911 Format sc reen (p ag e 1), in System CESID Default: field , enter your own system d efault and p ress En t e r. This is the numb er outp ulsed when the extension c od e is not found in the CAMA Numb ering tab le....
Page 176
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-58 Install the BRI Terminating Resistor 5 Screen 5-9. Class of Restriction form (page 1) 36. On the Class of Restric tion sc reen (pag e 1), in the Calling Party Restriction: field , typ e none and p ress En te r. 37. Typ e Save Translation and press En te r. Install the BRI Terminating Resistor The resistors...
Page 177
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-59 Install the BRI Terminating Resistor 5 nNever touc h uninsulated wires or terminals unless the telep hone line has b een d isc onnec ted at the network interfac e. nUse c aution when installing or mod ifying telephone lines. Terminating Resistor Adapter Fi g u re 5 - 2 1 shows an 8-p in 440A4 terminating...
Page 178
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-60 Install the BRI Terminating Resistor 5 Closet Mounted (110RA1-12) The 110RA1-12 terminating resistor bloc k is d esig ned to mount in the telec ommunic ations wire c loset. It c onsists of twelve 2-p air c irc uits and p rovid es the 100 Ohm termination used for ISDN-BRI c irc uits. Figure 5-22 shows the wiring...
Page 179
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-61 Install the BRI Terminating Resistor 5 Fi g u re 5 - 2 3 shows the wiring c onnec tions for the 110RA1-12 terminal bloc k. The TN556 BRI switc h p ort is terminated to b ottom row C. Figure 5-23. Typical Installation of Terminating Resistor Block Using Multi-point Connection For p oint-to-p oint wiring , the top...
Page 180
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-62 Install Multi-point Adapters 5 Install Multi-point Adapters Multi-p oint ad ap ters are used to p rovide sig nal fanout of the T-interfac e. Fanout c an b e p erformed at the work station b y the BR851-B or the 367A. These ad ap ters sup p ort more than one ISDN terminal p er horizontal 4-p air D-insid e wire...