Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 151
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-33 Install Emergency Transfer Units and Associated Telephones 5 5. On the trunk identific ation lab el at the b ottom of the p anel, rec ord the trunk line, extension, and loc ation for eac h c irc uit. 6. To eac h voic e terminal d esig nated as an emerg enc y terminal, attac h a label id entifying it as suc h....
Page 152
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-34 Install Emergency Transfer Units and Associated Telephones 5 The 808A is c onnec ted to the Main Distrib ution Frame (MDF) by means of a B25A cable. Fig ure 5-15 shows the c onnec tions at the trunk/auxiliary field for a telep hone used only for emerg enc y transfer. Figure 5-15. Connections for Telephone Used...
Page 153
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-35 Install Emergency Transfer Units and Associated Telephones 5 Fi g u re 5 - 1 6 shows the c onnec tions at the trunk/auxiliary field for a telep hone used for emerg enc y transfer as well as a normal extension. Figure 5-16. Connections for Telephone Used for Emergency Transfer and as Normal Extension Figure...
Page 154
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-36 Install Emergency Transfer Units and Associated Telephones 5 Install Telephone for Power Transfer Unit Trunk/Auxiliary Field: Telephone Used Only for Emergency Transfer 1. Connec t a p air of wires b etween the -48V and GRD terminals on the yellow emerg enc y transfer row/c onnec ting b loc k and the EM TRANS...
Page 155
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-37 Install External Ringing 5 Install External Ringing Connec tions for external ring ing are at an information outlet. The system sid e of the Main Distrib ution Frame (MDF) is c onnec ted to a TN2183 (or eq uivalent) Analog Line c irc uit p ac k. The c irc uitry and p ower sourc e for the d evic e are c...
Page 156
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-38 Install the 1145B Power Supply 5 Install the 1145B Power Supply The 1145B c loset p ower arrang ement p rovid es an uninterruptib le -48 VDC p ower sourc e with b attery and 1146B d istrib ution unit for ISDN/DCP, terminal eq uip ment, ad junc ts, and other c ustomer-sup p lied eq uip ment. During AC p ower...
Page 157
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-39 Install the 1145B Power Supply 5 Wall-Mounting Plates The top p late is used for mounting the bac k-up b attery. The b ottom p late is used to mount the p ower sup p ly and d istribution units. The plates c an be rac k- mounted using standard rack-mounting brackets. 1. Loc ate one plate d irec tly b elow the...
Page 158
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-40 Install the 1145B Power Supply 5 Figure 5-17. 1145B/1146B Mounting Arrangement Figure Notes 1. Wall Mounting Plate 2. Battery (1149B Shown) 3. 1146B Power Distrib ution Unit 4. 1145B Power Unit5. Power Cab le 6. Unswitc hed Outlet (120 VAC, 20 Amp or 230 VAC, 15 Amp ) 7. Battery Bac kup Switc h Setting 1145 Power...
Page 159
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-41 Install the 1145B Power Supply 5 Mount the 1146B Power Distribution Unit 1. Insert and sec urely tig hten the two sup p lied #8-32 x 1/2-inc h should er sc rews (they have an unthread ed sec tion at the top ) into the top holes d esig nated for 1146B Power Distrib ution Unit on the b ottom plate. Mount the...
Page 160
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-42 Install the 1145B Power Supply 5 Install the Expanded Power Distribution Unit A second power distribution unit can be installed to provide power to additional devices. !CAUTION: Total p ower c annot exc eed 275 Watts. The maximum ISDN terminal mixture is twenty four 7500-series and twenty four 8500-series...