    							APPENDIX D:  D.1 FACTORY DEFAULT SETTINGS
    GEK-113000-AFF650 DIGITAL BAY CONTROLLER d-25
    Digital Counter 6 nameDigCnt 6 Name  NA  
    Digital counter 6 PresetDigCnt 6 Preset0 1
    [-2147483648 : 
    2147483647] 
    Digital counter 6 CompareDigCnt 6 Compare0 1[-2147483648 : 2147483647] 
    Function permissionDigCnt 7 FunctionDISABLED NA  
    Digital Counter 7 nameDigCnt 7 Name  NA  
    Digital counter 7 PresetDigCnt 7 Preset0 1
    [-2147483648 : 
    2147483647] 
    Digital counter 7 CompareDigCnt 7 Compare0 1
    [-2147483648 : 
    2147483647] 
    Function permissionDigCnt 8 FunctionDISABLED NA  
    Digital Counter 8 nameDigCnt 8 Name  NA  
    Digital counter 8 PresetDigCnt 8 Preset0 1[-2147483648 : 2147483647] 
    Digital counter 8 CompareDigCnt 8 Compare0 1
    [-2147483648 : 
    2147483647] 
    Snapshot Event GenerationSnapshot EventsENABLED NA [ENABLED; DISABLED] 
    SETPOINT > CONTROL ELEMENTS > COLD LOAD PICK UP
    SETTING DESCRIPTIONNAMEDEFAULT VALUESTEP RANGEUSER 
    VALUE
    Function permsisionCold Load FunctionDISABLED NA[ENABLED; DISABLED]
    Cold Load Pickup Outage TimeCold Outage Time20
    mi
    n[1 : 1000]
    Cold Load Pickup Blocking TimeCold Blocking Time5s[1 : 1000]
    Snapshot Event GenerationCold Load EventsENABLED NA[ENABLED; DISABLED]
    Setpoint > Inputs/Outputs > Contact I/O >
    Board F > Board G >board h>board j
    Setting DescriptionNameDefault ValueStepRangeUser 
    Value
    I/O board type (available only for CIO 
    mo
     dules) I/O Board Type_
    XNONE N/A[NONE,
    16 INP + 8OUT,
    8 INP + 8OUT + SUPV
    32 INP
    16 INP + 8 ANA]
    Input activation voltage threshold Group A Voltage Threshold A_X80 1 V[10 : 230]
    Input activation voltage threshold Group BVoltage Threshold B _X801 V[10 : 230]
    Input activation voltage threshold Group C Voltage Threshold C_X80 1 V[10 : 230]
    Input activation voltage threshold Group D Voltage Threshold D_X80 1 V[10 : 230]
    Debounce time for Group A Debounce T ime A_X151 ms[1 : 50]
    Debounce time for Group B Debounce T ime B_X15 1 ms[1 : 50]
    Debounce time for Group C Debounce T ime C_X15 1 ms[1 : 50]
    Debounce time for Group D Debounce T ime D_X15 1 ms[1 : 50]
    Input type Input Type_X_C
     CY 
    (CCY ) POSITIVE
    N/A[POSITIVE-EDGE,
    NEGATIVE-EDGE,
    POSITIVE,
    NEGATIVE]
    Input signal time delay Delay Input 
    Ti
    
    me_ X_CC Y (CC Y) 0
    1 ms[0 : 60000]
    Output logic type Output Logic_X_0 Z POSITIVE N/A[POSITIVE,
    NEGATIVE] 
    						
    							D-26F650 DIGITAL BAY CONTROLLER GEK-113000-AF
    D.1 FACTORY DEFAULT SETTINGS APPENDIX D:  
    Output typeOutput Type_X_0 Z NORMAL N/A[NORMAL,
    PULSE,
    LATCH]
    Output pulse length Pulse Output 
    Ti
    
    me_ X_0 Z 10000
    1 ms[0 : 60000]
    Analog Inputs Range Range_X_0 Z NONE N/A[NONE,
    -1 to 0mA,
    0 to 1 mA,
    -1 to 1 mA,
    0 to 5 mA,
    0 to 10 mA]
    Minimum Value Min_Value_X_0 Z 0.00 0.01[ -9999.99 : 9999.99]
    Maximum Value Max_Value_X_0 Z 0.00 0.01[ -9999.99 : 9999.99]
    Snapshot event generation Snapshot EventsENABLEDN/A[DISABLED – ENABLED]
    Note 2: Description of X, Y and Z in input/output boards
    X  F,  G, H or J, the I/O board name, depending on the Relay model.
    F and G are internal Relay boards, and H and J are additional boards available in CIO 
    m
    
    odules (remote Bus CAN I/O module)
    For the I/O board selection in the relay 
    mo
     del:
    I/O BOARD TYPE
    ASSOCIATED DIGITENERVISTA 650 
    SETUP BOARD 
    SETTINGSBOARD TYPE
    0 NONENone
    1 16 INP+ 8 OUT
    Mixed 
    28 INP +8 OUT +SUPVSupervision 
    4 32 INP32 digital inputs 
    5 16 INP + 8 ANA16 digital inputs + 8 analog inputs 
    CC Y Is the name used for inputs in I/O boards
    Mixed, 
    16 d
    igital inputs: CC1….CC16
    Supervision:  8 d
     igital inputs: CC1,..., CC8
    32 INP: 32 digital inputs; CC1,...,CC32
    0 Z Is the name used for the different outputs in I/O boards, 8 outputs available for any of the 
    two t
    
    ypes of board (01,…., 08)
    Setpoint > inputs/outputs > remote comms
    Setting DescriptionNameDefault ValueStepRangeUser 
    Value
    Remote comms selection Remote CommsNONEN/A[NONE – GSSE – GOOSE]
    SETTING DESCRIPTION FOR GSSE
    Remote comms selection Remote CommsGSSEN/A[NONE – GSSE – GOOSE]
    Device Identif ication 650 IDF650N/A
    Hold time signal send by the transmiting 
    device Hold T ime
    100001 ms[1000 : 60000]
    Snapshot Events Generation Snapshot Events 
    Rem
    
    ote Out DISABLED
    N/A[DISABLED – ENABLED]
    Remote Device DescriptionRemote Device XRemote Device XN/A
    Bit Pair Selection Bit Pair XNoneN/A[DNA-1 to DNA-32 – 
    UserS
    t-1 to UserSt-64]
    Default Value Selection Default Value XOFFN/A[OFF –  ON – LATEST OFF – 
    LA
    
    TEST ON]
    SETTING DESCRIPTION FOR GoOSE
    Remote comms selection Remote CommsGOOSEN/A[NONE – GSSE – GOOSE] 
    						
    							APPENDIX D:  D.1 FACTORY DEFAULT SETTINGS
    GEK-113000-AFF650 DIGITAL BAY CONTROLLER d-27
    Default Value SelectionDefault Value XOFFN/A[OFF – ON – LATEST OFF – 
    LA
    TEST ON]
    Note: X is the Remote Device index, up to 32
    LIST OF TIME OVERCURRENT CURVES AVAILABLE IN F650
    IEEE extremely/very/moderately inverse
    IEC Curve A/B/C/Long-T ime Inverse/ Short-T ime Inverse
    IAC extremely/very/normally/moderately inverse
    ANSI extremely/very/normally/moderately inverse
    I2t
    Def inite time
    Rectif ier curve
    User Curve - FlexCurve™ A/B/C/D 
    						
    							D-28F650 DIGITAL BAY CONTROLLER GEK-113000-AF
    D.2 FACTORY DEFAULT CONFIGURATION APPENDIX D:  
    D.2  Factory default conf iguration
     
      
        
    NOTE:
    SOURCE COLUMN:
    This columns allow selecting the simple or complex (OR signal  or Virtual output) operand that actives the selected elements 
    on relay configuration
    If more than one operands are selected, the relay performs an OR gate with them to activate the selected element.
    SIGNAL LOGIC COLUMN:
    Refers to each individual signal selected on its left. NOT legend means that the refered signal is inverted
    SOURCE LOGIC COLUMN:
    Refers to the whole SOURCE  signal selected on its left. NOT legend means that SOURCE signal is inverted
    If more than one operand were selected, the OR gate output is inverted
    SETPOINT > RELAY CONFIGURATION > OUTPUTS 
    OUTPUTSOURCESOURCE LOGICLOGIC
    CONT OP OPER_F_01 VO_000_PROTECTION_ALARM -
    CONT OP OPER_F_02 VO_046_59P_PKP
    -
    VO_045_27P_PKP -
    CONT OP OPER_F_03 VO_048_50G_PKP -
    CONT OP OPER_F_04 VO_049_51G_PKP -
    CONT OP OPER_F_05 VO_051_50PH_PKP
    -
    VO_050_50PL_PKP -
    CONT OP OPER_F_06 VO_053_51P_PKP -
    CONT OP OPER_F_07 OPERATION BIT 1
    -
    AR CLOSE BREAKER -
    CONT OP OPER_F_08 OPERATION BIT 2
    -
    VO_083_GENERAL_TRIP -
    SETPOINT > RELAY CONFIGURATION > LEDS
    LED SOURCESOURCE LOGICLOGICLED NAME 
    LED01VO_000_PROTECTION ALARM-PROT ALARM
    LED02VO_083_GENERAL_TRIP-TRIP
    LED03VO_019_PHASE_OVERCURRENT_TRIP-50/51P TRIP
    LED04VO_069_GROUND_OVERCURRENT_TRIP-50/51G TRIP
    LED05VO_074_59P_TRIP--27/59 TRIPVO_073_27P_TRIP
    LED06VO_085_GENERAL_PKP-PICKUP
    LED07VO_007_PHASE_OVERCURRENT_PKP-50/51P PICKUP
    LED08VO_009_GROUND_OVERCURRENT_PKP-50/51G PICKUP
    LED09VO_045_27P_PKP-27 PICKUP
    LED10VO_046_59P_PKP-59 PICKUP
    LED11AR READY-79 READY
    LED12AR RCL IN PROGRESS-79 IN-PROG
    LED13AR BLOCK-79 BLOCK
    LED14AR CONDS INPUTNOT79 INHIBIT
    LED15AR LOCKOUT-79 LOCKOUT 
    						
    							APPENDIX D:  D.2 FACTORY DEFAULT CONFIGURATION
    GEK-113000-AFF650 DIGITAL BAY CONTROLLER d-29
    SETPOINT > RELAY CONFIGURATION > PROTECTION ELEMENTS
    PROTECTION ELeMENTSOURCESIGNAL LOGICSOURCE LOGIC
    LED RESET INPUTOPERATION BIT 3
    CHANGE LOCAL-REMOTENot Conf igured
    CHANGE OP BLOCKED Not Conf igured
    HMI BACKLIGHT ON Not Conf igured
    HMI BACKLIGHT OFF Not Conf igured
    PH IOC1 HIGH A BLK GROUP 1 BLOCKED
    CONT IP_F_CC2 (50P BLOCK)(CC2)
    PHASE DIR1 A OP
    NOT
    LATCHED VIRT IP 1 
    PH IOC1 HIGH B BLK GROUP 1 BLOCKED
    CONT IP_F_CC2 (50P BLOCK)(CC2)
    PHASE DIR1 B OP
    NOT
    LATCHED VIRT IP 1 
    PH IOC1 HIGH C BLK GROUP 1 BLOCKED
    CONT IP_F_CC2 (50P BLOCK)(CC2)
    PHASE DIR1 C OP
    NOT
    LATCHED VIRT IP 1 
    PH IOC2 HIGH A BLK GROUP 2 BLOCKED
    CONT IP_F_CC2 (50P BLOCK)(CC2)
    PHASE DIR2 A OP
    NOT
    LATCHED VIRT IP 1 
    PH IOC2 HIGH B BLK GROUP 2 BLOCKED
    CONT IP_F_CC2 (50P BLOCK)(CC2)
    PHASE DIR2 B OP
    NOT
    LATCHED VIRT IP 1 
    PH IOC2 HIGH C BLK GROUP 2 BLOCKED
    CONT IP_F_CC2 (50P BLOCK)(CC2)
    PHASE DIR2 C OP
    NOT
    LATCHED VIRT IP 1 
    PH IOC3 HIGH A BLK GROUP 3 BLOCKED
    CONT IP_F_CC2 (50P BLOCK)(CC2)
    PHASE DIR3 A OP
    NOT
    LATCHED VIRT IP 1 
    PH IOC3 HIGH B BLK GROUP 3 BLOCKED
    CONT IP_F_CC2 (50P BLOCK)(CC2)
    PHASE DIR3 B OP
    NOT
    LATCHED VIRT IP 1 
    PH IOC3 HIGH C BLK GROUP 3 BLOCKED
    CONT IP_F_CC2 (50P BLOCK)(CC2)
    PHASE DIR3 C OP
    NOT
    LATCHED VIRT IP 1 
    PH IOC1 LOW A BLK
    GROUP 1 BLOCKED
    CONT IP_F_CC2 (50P BLOCK)(CC2)
    PHASE DIR1 A OP NOT
    LATCHED VIRT IP 2 
    						
    							D-30F650 DIGITAL BAY CONTROLLER GEK-113000-AF
    D.2 FACTORY DEFAULT CONFIGURATION APPENDIX D:  
    PH IOC1 LOW B BLKGROUP 1 BLOCKED
    CONT IP_F_CC2 (50P BLOCK)(CC2)
    PHASE DIR1 B OP
    NOT
    LATCHED VIRT IP 2
    PH IOC1 LOW C BLK GROUP 1 BLOCKED
    CONT IP_F_CC2 (50P BLOCK)(CC2)
    PHASE DIR1 C OP
    NOT
    LATCHED VIRT IP 2
    PH IOC2 LOW A BLK GROUP 2 BLOCKED
    CONT IP_F_CC2 (50P BLOCK)(CC2)
    PHASE DIR2 A OP
    NOT
    LATCHED VIRT IP 2
    PH IOC2 LOW B BLK GROUP 2 BLOCKED
    CONT IP_F_CC2 (50P BLOCK)(CC2)
    PHASE DIR2 B OP
    NOT
    LATCHED VIRT IP 2
    PH IOC2 LOW C BLK GROUP 2 BLOCKED
    CONT IP_F_CC2 (50P BLOCK)(CC2)
    PHASE DIR2 C OP
    NOT
    LATCHED VIRT IP 2
    PH IOC3 LOW A BLK GROUP 3 BLOCKED
    CONT IP_F_CC2 (50P BLOCK)(CC2)
    PHASE DIR3 A OP
    NOT
    LATCHED VIRT IP 2
    PH IOC3 LOW B BLK GROUP 3 BLOCKED
    CONT IP_F_CC2 (50P BLOCK)(CC2)
    PHASE DIR3 B OP
    NOT
    LATCHED VIRT IP 2
    PH IOC3 LOW C BLK GROUP 3 BLOCKED
    CONT IP_F_CC2 (50P BLOCK)(CC2)
    PHASE DIR3 C OP
    NOT
    LATCHED VIRT IP 2
    NEUTRAL IOC1 BLOCK GROUP 1 BLOCKED
    NEUTRAL DIR1 OP
    NOT
    NEUTRAL IOC2 BLOCK GROUP 2 BLOCKED
    NEUTRAL DIR2 OP
    NOT
    NEUTRAL IOC3 BLOCK GROUP 3 BLOCKED
    NEUTRAL DIR3 OPNOT
    GROUND IOC1 BLOCKGROUP 1 BLOCKED
    CONT IP_F_CC5 (50G BLOCK)(CC5)
    GROUND DIR1 OP
    NOT
    LATCHED VIRT IP 3
    GROUND IOC2 BLOCK GROUP 2 BLOCKED
    CONT IP_F_CC5 (50G BLOCK)(CC5)
    GROUND DIR2 OP
    NOT
    LATCHED VIRT IP 3
    SETPOINT > RELAY CONFIGURATION > PROTECTION ELEMENTS
    PROTECTION ELeMENTSOURCESIGNAL LOGICSOURCE LOGIC 
    						
    							APPENDIX D:  D.2 FACTORY DEFAULT CONFIGURATION
    GEK-113000-AFF650 DIGITAL BAY CONTROLLER d-31
    GROUND IOC3 BLOCKGROUP 3 BLOCKED
    CONT IP_F_CC5 (50G BLOCK)(CC5)
    GROUND DIR3 OP
    NOT
    LATCHED VIRT IP 3
    SENS GND IOC1 BLK GROUP 1 BLOCKED
    SENS GND DIR1 OP
    NOT
    LATCHED VIRT IP 4
    SENS GND IOC2 BLK GROUP 2 BLOCKED
    SENS GND DIR2 OP
    NOT
    LATCHED VIRT IP 4
    SENS GND IOC3 BLK GROUP 3 BLOCKED
    SENS GND DIR3 OP
    NOT
    LATCHED VIRT IP 4
    PH TOC1 HIGH A BLK GROUP 1 BLOCKED
    CONT IP_F_CC3 (51P BLOCK)(CC3)
    PHASE DIR1 A OP
    NOT
    LATCHED VIRT IP 5
    PH TOC1 HIGH B BLK GROUP 1 BLOCKED
    CONT IP_F_CC3 (51P BLOCK)(CC3)
    PHASE DIR1 B OP
    NOT
    LATCHED VIRT IP 5
    PH TOC1 HIGH C BLK GROUP 1 BLOCKED
    CONT IP_F_CC3 (51P BLOCK)(CC3)
    PHASE DIR1 C OP
    NOT
    LATCHED VIRT IP 5
    PH TOC2 HIGH A BLK GROUP 2 BLOCKED
    CONT IP_F_CC3 (51P BLOCK)(CC3)
    PHASE DIR2 A OP
    NOT
    LATCHED VIRT IP 5
    PH TOC2 HIGH B BLK GROUP 2 BLOCKED
    CONT IP_F_CC3 (51P BLOCK)(CC3)
    PHASE DIR2 B OP
    NOT
    LATCHED VIRT IP 5
    PH TOC2 HIGH C BLKGROUP 2 BLOCKED
    CONT IP_F_CC3 (51P BLOCK)(CC3)
    PHASE DIR2 C OP
    NOT
    LATCHED VIRT IP 5
    PH TOC3 HIGH A BLK GROUP 3 BLOCKED
    CONT IP_F_CC3 (51P BLOCK)(CC3)
    PHASE DIR3 A OP
    NOT
    LATCHED VIRT IP 5
    PH TOC3 HIGH B BLK GROUP 3 BLOCKED
    CONT IP_F_CC3 (51P BLOCK)(CC3)
    PHASE DIR3 B OP
    NOT
    LATCHED VIRT IP 5
    SETPOINT > RELAY CONFIGURATION > PROTECTION ELEMENTS
    PROTECTION ELeMENTSOURCESIGNAL LOGICSOURCE LOGIC 
    						
    							D-32F650 DIGITAL BAY CONTROLLER GEK-113000-AF
    D.2 FACTORY DEFAULT CONFIGURATION APPENDIX D:  
    PH TOC3 HIGH C BLKGROUP 3 BLOCKED
    CONT IP_F_CC3 (51P BLOCK)(CC3)
    PHASE DIR3 C OP
    NOT
    LATCHED VIRT IP 5
    NEUTRAL TOC1 BLOCK GROUP 1 BLOCKED
    NEUTRAL DIR1 OP
    NOT
    NEUTRAL TOC2 BLOCK GROUP 2 BLOCKED
    NEUTRAL DIR2 OP
    NOT
    NEUTRAL TOC3 BLOCK GROUP 3 BLOCKED
    NEUTRAL DIR3 OP
    NOT
    GROUND TOC1 BLOCK GROUP 1 BLOCKED
    CONT IP_F_CC6 (51G BLOCK)(CC6)
    GROUND DIR1 OP
    NOT
    LATCHED VIRT IP 7
    GROUND TOC2 BLOCK GROUP 2 BLOCKED
    CONT IP_F_CC6 (51G BLOCK)(CC6)
    GROUND DIR2 OP
    NOT
    LATCHED VIRT IP 7
    GROUND TOC3 BLOCK GROUP 3 BLOCKED
    CONT IP_F_CC6 (51G BLOCK)(CC6)
    GROUND DIR3 OP
    NOT
    LATCHED VIRT IP 7
    SENS GND TOC1 BLOCK GROUP 1 BLOCKED
    SENS GND DIR1 OP
    NOT
    LATCHED VIRT IP 8
    SENS GND TOC2 BLOCK GROUP 2 BLOCKED
    SENS GND DIR2 OP
    NOT
    LATCHED VIRT IP 8
    SENS GND TOC3 BLOCK
    GROUP 3 BLOCKED
    SENS GND DIR3 OPNOT
    LATCHED VIRT IP 8
    PHASE UV1 BLOCK GROUP 1 BLOCKED
    PHASE UV2 BLOCK GROUP 2 BLOCKED
    PHASE UV3 BLOCK GROUP 3 BLOCKED
    NEG SEQ OV1 BLOCK GROUP 1 BLOCKED
    NEG SEQ OV2 BLOCK GROUP 2 BLOCKED
    NEG SEQ OV3 BLOCK GROUP 3 BLOCKED
    THERMAL1 BLOCK GROUP 1 BLOCKED
    THERMAL2 BLOCK GROUP 2 BLOCKED
    THERMAL3 BLOCK GROUP 3 BLOCKED
    PHASE DIR1 BLK INP GROUP 1 BLOCKED
    CONT IP_F_CC4 (67P BLOCK)(CC4)
    LATCHED VIRT IP 9
    PHASE DIR2 BLK INP GROUP 2 BLOCKED
    CONT IP_F_CC4 (67P BLOCK)(CC4)
    LATCHED VIRT IP 9
    SETPOINT > RELAY CONFIGURATION > PROTECTION ELEMENTS
    PROTECTION ELeMENTSOURCESIGNAL LOGICSOURCE LOGIC 
    						
    							APPENDIX D:  D.2 FACTORY DEFAULT CONFIGURATION
    GEK-113000-AFF650 DIGITAL BAY CONTROLLER d-33
    PHASE DIR3 BLK INPGROUP 3 BLOCKED
    CONT IP_F_CC4 (67P BLOCK)(CC4)
    LATCHED VIRT IP 9
    NEUTRAL DIR1 BLK INP GROUP 1 BLOCKED
    NEUTRAL DIR2 BLK INP GROUP 2 BLOCKED
    NEUTRAL DIR3 BLK INP GROUP 3 BLOCKED
    GROUND DIR1 BLK INP GROUP 1 BLOCKED
    LATCHED VIRT IP 10
    GROUND DIR2 BLK INP GROUP 2 BLOCKED
    LATCHED VIRT IP 10
    GROUND DIR3 BLK INP GROUP 3 BLOCKED
    LATCHED VIRT IP 10
    NEUTRAL OV1 HIGH BLK GROUP 1 BLOCKED
    LATCHED VIRT IP 12
    NEUTRAL OV2 HIGH BLK GROUP 2 BLOCKED
    LATCHED VIRT IP 12
    NEUTRAL OV3 HIGH BLK GROUP 3 BLOCKED
    LATCHED VIRT IP 12
    NEUTRAL OV1 LOW BLK GROUP 1 BLOCKED
    NEUTRAL OV2 LOW BLK GROUP 2 BLOCKED
    NEUTRAL OV3 LOW BLK GROUP 3 BLOCKED
    AUXILIARY UV1 BLOCK GROUP 1 BLOCKED
    AUXILIARY UV2 BLOCK GROUP 2 BLOCKED
    AUXILIARY UV3 BLOCKGROUP 3 BLOCKED
    PHASE OV1 BLOCKGROUP 1 BLOCKEDLATCHED VIRT IP 11
    PHASE OV2 BLOCK GROUP 2 BLOCKED
    LATCHED VIRT IP 11
    PHASE OV3 BLOCK GROUP 3 BLOCKED
    LATCHED VIRT IP 11
    AUXILIARY OV1 BLOCK GROUP 1 BLOCKED
    AUXILIARY OV2 BLOCK GROUP 2 BLOCKED
    AUXILIARY OV3 BLOCK GROUP 3 BLOCKED
    NEG SEQ TOC1 BLOCK GROUP 1 BLOCKED
    NEG SEQ TOC2 BLOCK GROUP 2 BLOCKED
    NEG SEQ TOC3 BLOCK GROUP 3 BLOCKED
    OVERFREQ1 BLOCK GROUP 1 BLOCKED
    OVERFREQ2 BLOCK GROUP 2 BLOCKED
    OVERFREQ3 BLOCK GROUP 3 BLOCKED
    UNDERFREQ1 BLOCK GROUP 1 BLOCKED
    UNDERFREQ2 BLOCK GROUP 2 BLOCKED
    UNDERFREQ3 BLOCK GROUP 3 BLOCKED
    SETT GROUPS BLOCK Not Conf igured
    BROKEN CONDUCT1 BLK GROUP 1 BLOCKED
    BROKEN CONDUCT2 BLK GROUP 2 BLOCKED
    BROKEN CONDUCT3 BLK GROUP 3 BLOCKED
    ISOLATED GND1 BLK GROUP 1 BLOCKED
    SENS GND DIR1 OP
    NOT
    SETPOINT > RELAY CONFIGURATION > PROTECTION ELEMENTS
    PROTECTION ELeMENTSOURCESIGNAL LOGICSOURCE LOGIC 
    						
    							D-34F650 DIGITAL BAY CONTROLLER GEK-113000-AF
    D.2 FACTORY DEFAULT CONFIGURATION APPENDIX D:  
    ISOLATED GND2 BLKGROUP 2 BLOCKED
    SENS GND DIR2 OP
    NOT
    ISOLATED GND3 BLK GROUP 3 BLOCKED
    SENS GND DIR3 OP
    NOT
    SENS GND DIR1 BLK IP GROUP 1 BLOCKED
    SENS GND DIR2 BLK IP GROUP 2 BLOCKED
    SENS GND DIR3 BLK IP GROUP 3 BLOCKED
    FWD PWR1 BLOCK GROUP 1 BLOCKED
    FWD PWR2 BLOCK GROUP 2 BLOCKED
    FWD PWR3 BLOCK GROUP 3 BLOCKED
    PH TOC1 LOW A BLK GROUP 1 BLOCKED
    CONT IP_F_CC3 (51P BLOCK)(CC3)
    PHASE DIR1 A OP
    NOT
    LATCHED VIRT IP 6
    PH TOC1 LOW B BLK GROUP 1 BLOCKED
    CONT IP_F_CC3 (51P BLOCK)(CC3)
    PHASE DIR1 B OPNOT
    LATCHED VIRT IP 6
    PH TOC1 LOW C BLK GROUP 1 BLOCKED
    CONT IP_F_CC3 (51P BLOCK)(CC3)
    PHASE DIR1 C OP
    NOT
    LATCHED VIRT IP 6
    PH TOC2 LOW A BLK GROUP 2 BLOCKED
    CONT IP_F_CC3 (51P BLOCK)(CC3)
    PHASE DIR2 A OP
    NOT
    LATCHED VIRT IP 6
    PH TOC2 LOW B BLK GROUP 2 BLOCKED
    CONT IP_F_CC3 (51P BLOCK)(CC3)
    PHASE DIR2 B OP
    NOT
    LATCHED VIRT IP 6
    PH TOC2 LOW C BLK GROUP 2 BLOCKED
    CONT IP_F_CC3 (51P BLOCK)(CC3)
    PHASE DIR2 C OP
    NOT
    LATCHED VIRT IP 6
    PH TOC3 LOW A BLK GROUP 3 BLOCKED
    CONT IP_F_CC3 (51P BLOCK)(CC3)
    PHASE DIR3 A OP
    NOT
    LATCHED VIRT IP 6
    PH TOC3 LOW B BLK GROUP 3 BLOCKED
    CONT IP_F_CC3 (51P BLOCK)(CC3)
    PHASE DIR3 B OP
    NOT
    LATCHED VIRT IP 6
    PH TOC3 LOW C BLK GROUP 3 BLOCKED
    CONT IP_F_CC3 (51P BLOCK)(CC3)
    PHASE DIR3 C OP
    NOT
    LATCHED VIRT IP 6
    DIR PWR1 BLOCK GROUP 1 BLOCKED
    DIR PWR2 BLOCK GROUP 2 BLOCKED
    SETPOINT > RELAY CONFIGURATION > PROTECTION ELEMENTS
    PROTECTION ELeMENTSOURCESIGNAL LOGICSOURCE LOGIC 
    						